The lubrication performance of the ceramic-on-ceramic hip implant under starved conditions
Source abstract
Abstract
Lubrication plays an important role in the clinical performance of the ceramic-on-ceramic (CoC) hip implant in terms of reducing wear and avoiding squeaking. All the previous lubrication analyses of CoC hip implants assumed that synovial fluid was sufficiently supplied to the contact area. The aim of this study was to investigate the lubrication performance of the CoC hip implant under starved conditions. A starved lubrication model was presented for the CoC hip implant. The model was solved using multi-grid techniques. Results showed that the fluid film thickness of the CoC hip implant was affected by fluid supply conditions: with the increase in the supplied fluid layer, the lubrication film thickness approached to that of the fully blooded solution; when the available fluid layer reduced to some level, the fluid film thickness considerably decreased with the supplying condition. The above finding provides new insights into the lubrication performance of hip implants.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Dental materials and restorations · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Wear of 36-mm BIOLOX (R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions10.1177/0954411912474613 ↗
2. High friction moments in large hard-on-hard hip replacement bearings in conditions of poor lubrication10.1002/jor.22255 ↗
3. Film thickness in starved EHL point contacts10.1115/1.2834175 ↗
4. Chevillotte, C., Trousdale, R.T., Chen, Q.S., Guyen, O., An, K.N., 2010. The 2009 Frank Stinchfield Award “Hip Squeaking” a biomechanical study of ceramic-on-ceramic bearing surfaces. Clin. Orthop. Relat. Res. 468, 345-350.10.1007/s11999-009-0911-x ↗
5. The rheology of synovial fluid and some potential synthetic lubricants for degenerate synovial joints10.1243/EMED_JOUR_1978_007_021_02 ↗
6. Starved lubrication of elliptical EHD contacts10.1115/1.1631020 ↗
7. Biotribology of artificial hip joints10.5312/wjo.v6.i1.77 ↗
8. A hip joint simulator study of the performance of metal-on-metal joints – Part 2: design
9. Comparison of numerical methods for elastohydrodynamic lubrication analysis of metal-on-metal hip implants: multi-grid verses Newton–Raphson10.1243/13506501JET228 ↗
10. Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion10.1243/0954411011536136 ↗
11. The Squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty10.2106/JBJS.F.00970 ↗
12. Theoretical studies of elastohydrodynamic lubrication of artificial hip joints10.1243/13506501JET144 ↗
13. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus10.1243/0954411971534359 ↗
14. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions10.1016/j.jbiomech.2005.01.031 ↗
15. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication10.1016/j.clinbiomech.2003.12.011 ↗
16. Lubrication and wear modelling of artificial hip joints: a review10.1016/j.triboint.2010.06.010 ↗
17. Lubrication modelling of artificial hip joints
18. Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with an aspherical acetabular bearing surface
19. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface10.1016/j.jbiomech.2009.11.018 ↗
20. Contact mechanics and lubrication analyses of ceramic-on-metal total hip replacements10.1016/j.triboint.2012.02.012 ↗
21. Hip joint fluid: detection and distribution at MR imaging and US with cadaveric correlation10.1148/radiology.208.1.9646791 ↗
22. In vitro investigation of friction under edge loading conditions for ceramic-on-ceramic total hip prosthesis10.1002/jor.21100 ↗
23. Venner · 2000
24. Film thickness modulations in starved elastohydrodynamically lubricated contacts induced by time-varying lubricant supply
25. Prediction of elastic deformation of acetabular cups and femoral heads for lubrication analysis of artificial hip joints10.1243/1350650041323331 ↗
26. A study on starved micro-thermal elastohydrodynamic lubrication in simple sliding circular contacts10.1243/13506501JET223 ↗
27. A study of the effect of model geometry and lubricant rheology upon the elastohydrodynamic lubrication performance of metal-on-metal hip joints10.1243/13506501JET363 ↗
28. Wijnant · 1998
29. Wijnant, Y.H., Venner, C.H., 1999. Contact dynamics in starved elastohydrodynamic lubrication. Lubrication at the Frontier: The Role of the Interface and Surface Layers in the Thin Film and Boundary Regime 36, pp. 705–716.10.1016/S0167-8922(99)80089-3 ↗
30. The influences of lubricant and material on polymer/CoCr sliding friction10.1016/S0043-1648(03)00180-7 ↗
31. Thermal elastohydrodynamic lubrication of starved elliptical contacts10.1016/j.triboint.2009.01.007 ↗