journal article·2019-03

The denticulate ligament – Tensile characterisation and finite element micro-scale model of the structure stabilising spinal cord

Katarzyna Polak-Kraśna, Sandra Robak-Nawrocka, Sylwia Szotek, Marcin Czyż, Daniel Gheek, Celina Pezowicz

Publisher page

Abstract

Background Damage to the spinal cord is one of the most debilitating pathologies with considerable health, economic and social impact. Improved prevention, treatment and rehabilitation after spinal cord injury (SCI) requires the complex biomechanics of the spinal cord with all its structural elements and the injury mechanism to be understood. This comprehensive understanding will also allow development of models and tools enabling better diagnosis, surgical treatment with increased safety and efficacy and possible development of regenerative therapies. The denticulate ligaments play an important role in stabilising spinal cord within the spinal canal. They participate in spinal cord movements and play a role in determining the stress distribution during physiological but also traumatic loading. We present detailed tensile characterisation of the denticulate ligaments and a Finite Element micro-scale model of the ligament relating its structure with the distribution of stress under physiological loading. Method Denticulate ligaments were dissected from cervical spinal levels from 6 porcine cervical specimens with fragments of the pia and dura mater and characterised in terms of their geometry and response to uniaxial tensile loading. The stress-strain characteristics were recorded until rupture of the ligament, ultimate parameters and Young's moduli were determined. The parametric micro-structural Finite Element model was constructed based on literature microscope and histological images of a denticulate ligament as a phenomenological representation of the complex microstructure of a soft tissue. The model was validated against the experimental data. Results Stress-strain characteristics obtained in tensile test were typical for a soft tissue behaviour. No statistically relevant differences in ultimate strength, strain and Young's moduli were observed between the ligaments harvested from different vertebral levels. Average ultimate tensile stress was 1.26 ± 0.20 MPa at strain 0.51 ± 0.00, rupturing force (1.01 ± 0.21 N) was in agreement with results obtained previously. The Finite Element model accurately predicted the extension-load behaviour of the denticulate ligament in elastic regime. The micro-scale structural representation enabled capturing deformation modes representative of the experimentally observed behaviour. Conclusions The presented stress-strain characteristics of the denticulate ligaments add valuable data to the understanding of the biomechanics of the spinal cord and enable development of more accurate models. The developed micro-scale model was capable of capturing biomechanical response of collagenous tissue under tensile loading, it can be applied for the prediction of other soft tissues behaviours. The denticulate ligament model should be included into future spinal cord models to fully represent the complex system's biomechanics and enable development of surgical aid tools to improve patient outcomes and future regenerative therapies.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cervical and Thoracic Myelopathy · Spinal Cord Injury Research · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. The mechanical properties of the human cervical spinal cord in vitro10.1007/BF02770996 ↗
2. The denticulate ligament: anatomical properties, functional and clinical significance10.1007/s00701-012-1361-x ↗
3. Cowin · 2007
4. The biomechanical analysis of the traumatic cervical spinal cord injury using finite element approach
5. Numerical model of the human cervical spinal cord--the development and validation
6. Critical values of mechanical stress and strain during traumatic cervical spinal cord injury: clinical study with the use of finite element modelling
7. Measurement of elastic modulus of collagen Type I single fiber10.1371/journal.pone.0145711 ↗
8. Kinking of the medulla in children with acute cerebral oedema and hydrocephalus and its relationship to the dentate ligaments10.1136/jnnp.30.3.267 ↗
9. An anatomic, myelographic and cinemyelographic study of the dentate ligaments10.2214/ajr.98.3.704 ↗
10. Ligament structure, physiology and function
11. A three-dimensional finite element model of the cervical spine with spinal cord: an investigation of three injury mechanisms10.1007/s10439-008-9440-0 ↗
12. Microsurgical anatomy of the denticulate ligaments and their relationship with the axilla of the spinal nerve roots10.1002/ca.22292 ↗
13. Upper brain-stem compression and foraminal impaction with intracranial space-occupying lesions and brain swelling10.1093/brain/82.4.525 ↗
14. A demographic profile of new traumatic spinal cord injuries: change and stability over 30 years10.1016/j.apmr.2004.04.035 ↗
15. Structure of the tendon connective tissue10.1034/j.1600-0838.2000.010006312.x ↗
16. The Multicomposite Structure of Tendon10.3109/03008207809152283 ↗
17. The global map for traumatic spinal cord injury epidemiology: update 2011, global incidence rate10.1038/sc.2012.158 ↗
18. Three-dimensional finite element model of the cervical spinal cord: preliminary results of injury mechanism analysis10.1097/BRS.0b013e31819e2af1 ↗
19. Finite element analysis of spinal cord injury in the rat10.1089/neu.2007.0423 ↗
20. Immediate damage to the blood-spinal cord barrier due to mechanical trauma10.1089/neu.2006.0149 ↗
21. Strain rate dependent properties of younger human cervical spine ligaments10.1016/j.jmbbm.2012.02.004 ↗
22. Discovery of a novel fibrous tissue in the spinal pia mater by polarized light microscopy10.3109/03008207.2013.879864 ↗
23. The fine anatomy of the human spinal meninges. A light and scanning electron microscopy study10.3171/jns.1988.69.2.0276 ↗
24. Mechanical properties and function of the spinal pia mater
25. Biomechanics of nonacute cervical spinal cord trauma10.1097/00007632-198807000-00024 ↗
26. Biomechanical characteristics of the porcine denticulate ligament in different vertebral levels of the cervical spine-preliminary results of an experimental study10.1016/j.jmbbm.2014.02.010 ↗
27. Collagen fibril morphology and organization: implications for force transmission in ligament and tendon10.1016/j.matbio.2005.09.005 ↗
28. Elongation mechanism of collagen fibrils and force-strain relations of tendon at each level of structural hierarchy10.1016/0021-9290(96)00024-3 ↗
29. Morphological features of fascia lata in relation to fascia diseases10.1080/01913123.2016.1239665 ↗
30. The denticulate ligament: anatomy and functional significance
31. Elasticity of the spinal cord, pia, and denticulate ligament in the dog10.3171/jns.1978.48.6.0975 ↗
32. Functional tissue engineering of ligament and tendon injuries A2 - Atala, Anthony (Chapter 54)
33. Wolrd Health Organisation, 2013. Fact sheet No 384 Spinal cord injury. (Online). Available: 〈http://www.who.int/mediacentre/factsheets/fs384/en/〉. (Accessed 03 Feb 2018).