journal article·2019-03

How much force is required to perforate a colon during colonoscopy? An experimental study

Steve Johnson, Michael Schultz, Mario Scholze, Troy Smith, John Woodfield, Niels Hammer

Publisher page

Abstract

Introduction Colonoscopy is a commonly-performed procedure to diagnose pathology of the large intestine. Perforation of the colon is a rare but feared complication. It is currently unclear how much force is actually required to cause such injury nor how this is altered in certain diseases. Our aim was to analyze the forces required to perforate the colon in experiments using porcine tissues. Methods Using 3D printing technology, models of two commercially available colonoscope heads were printed under three configurations: straight (I), 90°- bent (L) and fully bent (U). Samples of porcine colon were assessed with the models and configurations under perpendicular and angular load application and these data compared to the maximum force typically exerted by experienced colonoscopists. Results The force required for perforation was significantly lower for the I compared to the L of the larger colonoscope head configuration under angular loading (14.1 vs. 46.5 N). Similar differences were found for linear stiffness when loaded (I vs. L small when loaded perpendicular: 0.8 vs. 2.4 N/mm, I vs. L large when loaded angled 0.7 vs. 2.1 N/mm). The mode and site of failure varied significantly between the scopes, with delamination of the mucosa/submucosa below the sample (96%) for the I, blunt mucosa/submucosa/muscularis failure adjacent to the loading site (77%) for the L, and failure of all colon layers lateral to the loading site (59%) for the U configuration, respectively. Perpendicular and angulated loading resulted in similar load-deformation values. Maximum forces typically exerted by colonoscopists averaged 13.9-27.9 N, depending on the colonoscope model and head configuration. Discussion The force required for colon perforation varies depending on the type mode of loading and is likely lower than the force an experienced colonoscopist would exert in daily practice. There is a real risk of perforation, especially when the end of the scope is advancing directly into the colonic wall. The given experimental setup allowed to obtain reliable data of the colon in a standardized scenario, forming the basis for further experiments.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Colorectal Cancer Screening and Detection · Medical Device Sterilization and Disinfection · Gastrointestinal Bleeding Diagnosis and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Biaxial mechanical modeling of the small intestine10.1016/j.jmbbm.2011.05.030 ↗
2. Computational tools for the analysis of mechanical functionality of gastrointestinal structures10.3233/THC-130722 ↗
3. Constitutive formulations for the mechanical investigation of colonic tissues10.1002/jbm.a.34787 ↗
4. Sensor architecture for a two-actuator robotic endoscope tip
5. Modeling and in vitro experimental validation for kinetics of the colonoscope in colonoscopy10.1007/s10439-013-0746-1 ↗
6. Overview of upcoming advances in colonoscopy10.1111/j.1443-1661.2011.01181.x ↗
7. Colorectal perforation by self-induced hydrostatic pressure: a report of two cases10.1016/j.jemermed.2012.02.076 ↗
8. Prevalence and lifetime risk of endoscopy-related complications among patients with inflammatory bowel disease10.1016/j.cgh.2013.04.047 ↗
9. Role of virtual reality simulation in endoscopy training10.4253/wjge.v7.i18.1287 ↗
10. Material properties of the post-mortem small intestine in high-rate equibiaxial elongation
11. Mechanical analysis of insertion problems and pain during colonoscopy: why highly skill-dependent colonoscopy routines are necessary in the first place… and how they may be avoided10.1155/2013/353760 ↗
12. Colonoscopic perforation: incidence, risk factors, management and outcome10.3748/wjg.v16.i4.425 ↗
13. Dynamic biomechanical characterization of colon tissue according to anatomical factors10.1016/j.jbiomech.2016.10.023 ↗
14. Prevalence and risk factors for colonic perforation during colonoscopy in hospitalized inflammatory bowel disease patients10.1016/j.crohns.2010.12.005 ↗
15. Colonoscopy perforation rate, mechanisms and outcome: from diagnostic to therapeutic colonoscopy10.1055/s-0029-1215179 ↗
16. Bleeding and perforation after outpatient colonoscopy and their risk factors in usual clinical practice10.1053/j.gastro.2008.08.058 ↗
17. How many endoscopies are performed for colorectal cancer screening? Results from CDC's survey of endoscopic capacity10.1053/j.gastro.2004.09.051 ↗
18. Strength of the colon wall in diverticular disease10.1002/bjs.1800770308 ↗
19. Mechanical properties of the colon: comparison of the features of the African and European colon in vitro10.1136/gut.26.4.384 ↗
20. Yamada · 1970