journal article·2022-05

Effect of central screw taper angles on the loosening performance and fatigue characteristics of dental implants

Fei Sun, Li-Tao Lv, Ding-Ding Xiang, De-Chun Ba, Zeng Lin, Gui-Qiu Song

Publisher page

Abstract

Biomechanical performance plays an important role in the long-term service of dental implants. Loosening and fatigue damage of the central screw are the most common problems. This research investigated the effect of the central screw taper angle on the loosening performance and fatigue characteristics of dental implants. Central screws with four taper angles, 30°, 60°, 90° and 180°, were processed and tested. The loosening performance of the screws under initial and postload conditions was compared. Then, the fatigue characteristics of dental implants was measured. Finally, the wear and fracture modes of the screws were observed. The damage locations were verified by finite element analysis (FEA). The results showed that the central screws with 30° taper had substantially better anti-loosening performance and less fretting wear. The central screws with 180° taper had a higher preload, resulting in a longer fatigue life. Furthermore, the fatigue fracture of the central screw occurred at the level of the first thread position, consistent with the FEA results. In the future clinical applications, central screws with a 30° taper angle may improve anti-loosening performance and prolong fatigue life by increasing the tightening torque.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes · Mechanical Failure Analysis and Simulation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw10.1016/S0300-9785(81)80077-4 ↗
2. Effects of overloading in mastication on the mechanical behaviour of dental implants10.1016/j.matdes.2012.12.019 ↗
3. Effect of double conical abutment screw on implant preload10.1111/clr.12623 ↗
4. Bickford · 1995
5. Fatigue induced changes in conical implant–abutment connections10.1016/j.dental.2015.09.004 ↗
6. Intraosseous anchorage of dental prostheses. I. Experimental studies
7. 1977 · 1
8. Effect of PEEK and PTFE coatings in fatigue performance of dental implant retaining screw joint: an in vitro study10.1016/j.jmbbm.2019.103530 ↗
9. Mechanical comparison of experimental conical-head abutment screws with conventional flat-head abutment screws for external-hex and internal tri-channel implant connections: an in vitro evaluation of loosening torque10.11607/jomi.3029 ↗
10. Fatigue lifetime prediction of a reduced-diameter dental implant system: numerical and experimental study10.1016/j.dental.2018.06.002 ↗
11. Influence of the coating material on the loosing of dental implant abutment screw joints-ScienceDirect10.1016/j.msec.2005.08.011 ↗
12. Investigation the effect of tightening torque on the fatigue strength of double lap simple bolted and hybrid (bolted–bonded) joints using volumetric method10.1016/j.matdes.2014.06.021 ↗
13. Effects of two fretting damage modes on the dental implant–abutment interface and the generation of metal wear debris: an in vitro study
14. A systematic review of the 5-year survival and complication rates of implant-supported single crowns10.1111/j.1600-0501.2007.01453.x ↗
15. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years10.1111/j.1600-0501.2007.01414.x ↗
16. Study on self-loosening of bolted joints excited by dynamic axial load10.1016/j.triboint.2017.05.037 ↗
17. Effects of abutment screw coating on implant preload10.1111/j.1532-849X.2010.00595.x ↗
18. An in vitro analysis of implant screw torque loss with external hex and internal connection implant systems10.1097/01.id.0000245440.09464.48 ↗
19. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years10.1111/j.1600-0501.2012.02546.x ↗
20. Evaluation of the sealing capability of the implant healing screw by using real time volatile organic compounds analysis: internal hexagon versus cone morse10.1902/jop.2016.160076 ↗
21. Identification of failure mechanisms in retrieved fractured dental implants. Eng. Fail
22. Random spectrum loading of dental implants: an alternative approach to functional performance assessment10.1016/j.jmbbm.2016.04.030 ↗
23. Shigley · 1977
24. The role of prosthetic abutment material on the stress distribution in a maxillary single implant-supported fixed prosthesis10.1016/j.msec.2016.04.004 ↗
25. Effect of surface modification on the long-term stability of dental implant abutment screws by plasma nitriding treatment10.1016/j.surfcoat.2020.126089 ↗
26. The relationship between time of retightening and preload loss of abutment screws for two different implant designs: an in vitro study10.1563/aaid-joi-D-18-00138 ↗
27. Comparison of the fracture resistance of dental implants with different abutment taper angles10.1016/j.msec.2016.02.015 ↗
28. Effect of lubricant on the reliability of dental implant abutment screw joint: an in vitro laboratory and three-dimension finite element analysis10.1016/j.msec.2016.11.041 ↗
29. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque value
30. Improving the long-term stability of Ti6Al4V abutment screw by coating micro/nano-crystalline diamond films10.1016/j.jmbbm.2016.06.018 ↗
31. The effect of abutment screw length on screw loosening in dental implants with external abutment connections after thermocycling10.11607/jomi.3125 ↗
32. Anti-loosening performance of coatings on fasteners subjected to dynamic shear load10.1007/s40544-017-0160-z ↗