Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human species
Source abstract
Abstract
Due to its proximity to the mitral valve, the coronary sinus (CS) vessel serves as a conduit for the deployment and implantation of the percutaneous transvenous mitral annuloplasty (PTMA) devices that can potentially reduce the mitral regurgitation. Because CS vessel is a venous tissue and seldom diseased, its mechanical properties have not been well studied. In this study, we performed a multi-axial mechanical test and histological analysis to characterize the mechanical and structural properties of the aged human, porcine and ovine CS tissues. The results showed that the aged human CS tissues exhibited much stiffer and highly anisotropic behaviors compared to the porcine and ovine. Both of the porcine and ovine CS vessel walls were thicker and mainly composed of striated muscle fibers (SMF), whereas the thinner aged human CS had higher collagen, less SMF, and more fragmented elastin fibers, which are possibly due to aging effects. We also observed that the anatomical features of porcine CS vessel might be not suitable for PTMA deployment. These differences between animal and human models raise questions for the validity of using animal models to investigate the biomechanics involved in the PTMA intervention. Therefore, caution must be taken in future studies of PTMA stents using animal models.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Experimental study and constitutive modelling of the passive mechanical properties of the ovine infrarenal vena cava tissue10.1016/j.jbiomech.2008.07.008 ↗
2. Anatomic and histologic review of the coronary sinus10.4067/S0717-95022004000400016 ↗
3. Cryopreservation procedure does not modify human carotid homografts mechanical properties: an isobaric and dynamic analysis10.1007/s10561-005-0655-0 ↗
4. Percutaneous mitral annular reduction provides continued benefit in an ovine model of dilated cardiomyopathy10.1161/01.CIR.0000146904.13677.E4 ↗
5. Passive mechanical properties of porcine left circumflex artery and its mathematical description10.1016/j.medengphy.2006.01.004 ↗
6. The anatomic basis of connections between the coronary sinus musculature and the left atrium in humans10.1161/01.CIR.101.6.647 ↗
7. The effect of pathophysiology on the surgical treatment of ischemic mitral regurgitation: operative and late risks of repair versus replacement10.1016/S1010-7940(05)80008-9 ↗
8. Percutaneous mitral valve repair for chronic ischemic mitral regurgitation: a real-time three-dimensional echocardiographic study in an ovine model10.1161/01.CIR.0000163547.03188.AC ↗
9. A model for passive elastic properties of rat vena cava10.1016/j.jbiomech.2007.03.028 ↗
10. Percutaneous mitral valve annuloplasty for ischemic mitral regurgitation: first in man experience with a temporary implant10.1002/ccd.21186 ↗
11. Feasibility and short-term efficacy of percutaneous mitral annular reduction for the therapy of functional mitral regurgitation in patients with heart failure
12. Results of open operation for acquired mitral valve disease10.1056/NEJM196504292721701 ↗
13. Fung · 1993
14. Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: implications in animal cardiovascular device trials10.1016/j.medengphy.2011.01.016 ↗
15. Is repair preferable to replacement for ischemic mitral regurgitation?10.1067/mtc.2001.116557 ↗
16. Ischemic mitral valve reconstruction and replacement: comparison of long-term survival and complications10.1067/mtc.2001.116945 ↗
17. Transcatheter implantation of the MONARC coronary sinus device for mitral regurgitation
18. Mitral valve reconstruction and replacement for ischemic mitral insufficiency: seven years’ follow up
19. Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling10.1152/ajpheart.00934.2004 ↗
20. Percutaneous mitral annuloplasty device leaves free access to cardiac veins for resynchronization therapy10.1002/ccd.22097 ↗
21. Caridac valve replacement in the elderly: clinical performance of biological prostheses10.1016/0003-4975(89)90064-7 ↗
22. Feasibility and short term efficacy of percutaneous mitral annular reduction for the therapy of hear failure-induced mitral regurgitation10.1161/01.CIR.0000096051.23734.28 ↗
23. Kohn · 1977
24. Structural and genetic bases of arterial stiffness10.1161/01.HYP.0000164580.39991.3d ↗
25. Percutaneous mitral valve repair: a feasibility study in an ovine model of acute ischemic mitral regurgitation10.1002/ccd.10662 ↗
26. Cardiac veins: a review of the literature10.1002/ca.20745 ↗
27. Acute and chronic reduction of functional mitral regurgitation in experimental heart failure by percutaneous mitral annuloplasty10.1016/j.jacc.2004.03.085 ↗
28. The elastic fibres: a regulator of normal and pathological ageing of elastic blood vessels
29. Characterization of the mechanical properties of the coronary sinus for percutaneous transvenous mitral annuloplasty10.1016/j.actbio.2010.05.028 ↗
30. Multiaxial mechanical behavior of biological materials10.1146/annurev.bioeng.5.011303.120714 ↗
31. Passive biaxial mechanical response of aged human iliac arteries10.1115/1.1574331 ↗
32. Percutaneous valve repair for mitral regurgitation using the carillon(TM)-mitral contour system(TM). Description of the method and case report
33. Effectiveness and safety of percutaneous coronary sinus-based mitral valve repair in patients with dilated cardiomyopathy (from the AMADEUS trial)10.1016/j.amjcard.2009.04.021 ↗
34. Finite element implementation of a generalized Fung-elastic constitutive model for planar tissues10.1007/s10237-005-0075-x ↗
35. Biaxial mechanical response of bioprosthetic heart valve biomaterials to high in-plane shear
36. Effects of ca-free and edta-containing tyrode solution on transmembrane electrical activity and contraction in guinea pig papillary muscle10.1007/BF00586077 ↗
37. Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus10.1161/CIRCULATIONAHA.105.591602 ↗