journal article·2014-03

Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator

Yoshimitsu Okazaki

Publisher page

Abstract

The effects of articular head size on the wear losses of the metal insert and articular head for a metal-on-metal bearing were examined using a hip simulator manufactured to satisfy ISO 14242-1. The wear properties of metal-on-metal and metal-on-polyethylene bearings were also compared under the same conditions. The total wear losses of the metal insert and articular head decreased with increasing diameter of the metal insert in the range from 28 to 44mm. The total wear loss was greater for a diameter of 48mm than for a diameter of 44mm. When the articular metal insert diameter was smaller than 44mm, the wear loss was reduced because the contact surface pressure increased with increasing metal insert diameter. However, the increase in wear loss observed for the 48-mm-diameter insert might have been due to the considerable increase in the rotation moment with increasing insert diameter. The tendency of decreasing contact pressure calculated using the Hertzian contact stress equation nearly conformed to the change in wear loss. On the other hand, the wear loss of an artificial hip joint consisting of a cross-linked ultrahigh-molecular-weight polyethylene insert (UHMWPE) and a Co-Cr-Mo articular head was small.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Tribology and total hip joint replacement: current concepts in mechanical simulation10.1016/j.medengphy.2008.07.006 ↗
2. Failed metal-on-metal hip arthroplasties: a spectrum of clinical presentations and operative findings10.1007/s11999-010-1419-0 ↗
3. Histological features of pseudotumor-like tissues from metal-on-metal hips10.1007/s11999-010-1372-y ↗
4. Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time10.1243/09544119JEIM112 ↗
5. New insights into wear and biological effects of metal-on-metal bearings10.2106/JBJS.J.01877 ↗
6. A groin mass caused by metal particle debris after hip resurfacing
7. The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium10.1302/0301-620X.88B4.17355 ↗
8. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements10.2106/JBJS.C.00949 ↗
9. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M ↗
10. A literature review of the association between wear rate and osteolysis in total hip arthroplasty10.1054/arth.2002.33664 ↗
11. Hip simulator wear comparison of metal-on-metal, ceramic-on-ceramic and crosslinked UHMWPE bearings10.1016/j.wear.2005.02.104 ↗
12. Comparison of hip simulator wear of 2 different highly cross-linked ultra high molecular weight polyethylene acetabular components using both 32- and 38-mm femoral heads10.1016/j.arth.2006.07.009 ↗
13. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
14. The pathology of joint replacement and tissue engineering10.1016/j.mpdhp.2012.01.004 ↗
15. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements10.1243/0954411001535228 ↗
16. The relationship between head–neck ratio and pseudotumour formation in metal-on-metal resurfacing arthroplasty of the hip10.1302/0301-620X.92B11.24640 ↗
17. Greenwald, A.S., et al., 2005. Highly crosslinked polyethylenes: hopes vs. realities. In: 72nd Annual Meeting, American Academy of Orthopaedic Surgeons. February 23–27, Washington, DC.
18. A review of current cross-linked polyethylenes used in total joint arthroplasty10.1097/01.blo.0000152603.58384.e9 ↗
19. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case–control study using three-dimensional computed tomography and magnetic resonance imaging10.2106/JBJS.J.01508 ↗
20. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement10.1302/0301-620X.93B10.26249 ↗
21. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses10.2106/JBJS.D.01820 ↗
22. Metal-on-metal bearing surfaces: materials, manufacture, design, optimization, and alternatives10.1243/095441105X68953 ↗
23. ISO 14242-1, 2002. Implants for Surgery – Wear of Total Hip-Joint Prostheses – Part 1: Loading and Displacement Parameters for Wear-Testing Machines and Corresponding Environmental Conditions for Test.
24. ISO 14242-2, 2000. Implants for Surgery – Wear of Total Hip-Joint Prostheses – Part 2: Methods of Measurement.
25. JIS T 0303, 2000. Testing Method for Wear Resistance of Materials for Artificial Joint by Pin-on-Disk Method.
26. Hip simulator wear testing according to the newly introduced standard ISO 1424210.1243/0954411011536019 ↗
27. Polyethylene wear of the porous-coated anatomic total hip arthroplasty with an average 11-year follow-up10.1054/arth.2001.28360 ↗
28. Aseptic lymphocyte dominated vasculitis-associated lesion resulting from trunnion corrosion in a cobalt-chrome unipolar hemiarthroplasty10.1016/j.arth.2012.04.010 ↗
29. Current in vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level10.1002/jor.20206 ↗
30. Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up10.2106/00004623-200606000-00003 ↗
31. Early results of large head metal-on-metal hip arthroplasties10.1177/145749691210100112 ↗
32. "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study10.1016/j.arth.2010.05.030 ↗
33. Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years10.1007/s11999-009-1038-9 ↗
34. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear10.1302/0301-620X.93B2.25099 ↗
35. Effect of femoral head size on wear of the polyethylene acetabular component10.2106/00004623-199072040-00008 ↗
36. Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test
37. The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip10.1302/0301-620X.94B8.27626 ↗
38. Manley, M.T., Dumbleton, J., 2002. Bearing surfaces. In: Barrack, R.L., et al. (Ed.), Orthopaedic Knowledge Update: Hip and Knee Reconstruction 3, American Academy of Orthopaedic Surgeons, pp. 333–344.
39. A novel method of cross-linking ultra-high-molecular weight-polyethylene to improve wear, reduce oxidation, and retain mechanical properties10.1054/arth.2001.20540 ↗
40. National Joint Replacement Registry, 2012. Hip and Knee Arthroplasty Annual Report. Australian Orthopaedic Association.
41. National Joint Registry for England and Wales. 2012. Ninth Annual Report.
42. Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis10.1007/s00264-010-1061-1 ↗
43. Metal ion effects on different types of cell line, metal ion incorporation into L929 and MC3T3-E1cells, and activation of macrophage-like J774.1 cells10.1016/j.msec.2013.01.015 ↗
44. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature10.1080/000164701753606644 ↗
45. Early osteolysis following second-generation metal-on-metal hip replacement
46. The multifactorial nature of polyethylene wear in vivo10.2106/00004623-199808000-00018 ↗
47. The wear of metal-on-metal total hip prostheses measured in a hip simulator10.1243/0954411011536118 ↗
48. The effect of femoral head diameter upon lubrication and wear of metal-on-metal bearing total hip replacements10.1243/0954411011533724 ↗
49. Toshimitsu T., et al., Strength Design Data Book, 1962. The Natural Science Publishers’ Association of Japan, p. 1077.
50. The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis10.2106/JBJS.J.00287 ↗
51. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement10.2106/00004623-200004000-00002 ↗
52. Aseptic lymphocyte-dominated vasculitis-associated lesion: a clinicopathologic review of an underrecognized cause of prosthetic failure10.1309/AJCPLTNEUAH8XI4W ↗
53. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study10.2106/00004623-200501000-00006 ↗
54. Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty10.2106/JBJS.J.01884 ↗
55. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty10.1080/17453670610012863 ↗