The coefficient of friction of UHMWPE along an entire walking cycle using a ball-on-disc tribometer under arthrokinematics and loading conditions prescribed by ISO 14243-3:2014
Source abstract
Abstract
The observation of tribological phenomena occurring in total knee replacement (TKR) simulators may be obscured by the intrinsic complexity of their operation: the dynamics and kinematics prescribed by the ISO 14243-3:2014 standard, and the geometry of the surfaces involved. On the other hand, evaluating the individual performance of the tribosystem elements may be carried out in simpler apparatuses. An experimental method is presented here, by means of which the arthrokinematics and loading conditions prescribed by the said standard are adapted to a ball-on-disc configuration in order to observe the behavior of the coefficient of friction along an entire walking cycle, using the contact point of an AISI 316L stainless steel ball rolling/sliding on an ultra-high molecular weight polyethylene (UHMWPE) disc, lubricated by a solution of fetal bovine serum, at 37°C. The method was tried on two different testing fluids prepared with protein concentrations of 20g/L, according to the said standard, and 36g/L, as received. The statistical model obtained for the behavior of the COF during the entire walking cycle may be used in numerical simulations of UHMWPE wear, under the conditions established by ISO 14243-3:2014.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique10.1016/j.arth.2004.08.005 ↗
2. Fan, J., Myant, C.W., Underwood, R., Cann, P.M., Hart, A., 2011. Inlet protein aggregation: a new mechanism for lubricating film formation with model synovial fluids. Proc. IMech E 225 H: J. Eng. Med. pp. 696–70910.1177/0954411911401306 ↗
3. Biotribology of alternative bearing materials for unicompartmental knee arthroplasty10.1016/j.actbio.2010.04.003 ↗
4. Biotribology of a new bearing material combination in a rotating hinge knee articulation10.1016/j.actbio.2013.02.030 ↗
5. Polycentric knee arthroplasty Prosthetic simulation of normal knee movement10.1302/0301-620X.53B2.272 ↗
6. Explicit finite element modeling of total knee replacement mechanics10.1016/j.jbiomech.2004.02.046 ↗
7. Explicit equations for the stresses beneath a sliding spherical contact10.1243/PIME_PROC_1983_197_076_02 ↗
8. A finite element model of the human knee joint for the study of tibio-femoral contact10.1115/1.1470171 ↗
9. Protein-mediated boundary lubrication in arthroplasty10.1016/j.biomaterials.2004.05.020 ↗
10. ISO 14243-3 · 2014
11. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 203010.1007/s11999-009-0834-6 ↗
12. The clinical performance of UHMWPE in knee replacements
13. An overview of recent advances in designing orthopedic and craniofacial implants10.1002/jbm.a.34605 ↗
14. A novel total knee replacement by rolling articulating surfaces. In vivo functional measurements and tests
15. Wear of UHMWPE from sliding, rolling, and rotation in a multidirectional tribosystem10.1016/j.wear.2013.04.017 ↗
16. A three-axis knee wear simulator with ball-on-flat contact10.1016/S0043-1648(01)00567-1 ↗
17. van Beek · 2006