Revision total knee arthroplasty using a novel 3D printed titanium augment: A biomechanical cadaveric study
Source abstract
Abstract
Background During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA. Methods Primary total knee arthroplasty (pTKA) surgery was performed on 11 pairs of thawed fresh-frozen cadaveric tibias (22 tibias). Fixation stability testing was conducted using a three-stage eccentric loading protocol. Bone-implant micromotion was measured using a high-resolution optical system. The pTKA were removed. Revision TKA was performed using a 3D printed titanium augment or a standard fully cemented stem. The three-stage eccentric loading protocol was repeated and micromotion was measured for the revision implants. Results After rTKA, the mean vertical micromotion was 28.1 μm ± (SD) 20.3 μm in the control group and 17.5 μm ± 18.7 μm in the experimental group. There was significantly less micromotion in the experimental group (p = 0.029). Conclusions This study suggests that early fixation stability of revision TKA with the novel 3D printed titanium augment is better then the conventional fully cemented rTKA. The early press-fit fixation of the augment is likely sufficient for promoting bony ingrowth of the augment in vivo. Further studies are needed to investigate the long-term in-vivo fixation of the novel 3D printed augment.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Cemented vs cementless total knee arthroplasty in morbidly obese patients10.1016/j.arth.2016.01.025 ↗
2. The effect of stem design on end-of-stem pain in revision total knee arthroplasty10.1016/j.arth.2004.06.009 ↗
3. The pathology of total joint arthroplasty10.1007/s002560050552 ↗
4. Correlation of tibial bone defect shape with patient demographics following total knee revision10.1016/j.jor.2018.03.025 ↗
5. Image-guided installation of 3D-printed patient-specific implant and its application in pelvic tumor resection and reconstruction surgery
6. Outcomes and aseptic survivorship of revision total knee arthroplasty
7. Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions10.1016/j.jbiomech.2009.12.006 ↗
8. CIHI
9. Management of bone defects in revision total knee arthroplasty10.2106/JBJS.L00143 ↗
10. Revision total knee arthroplasty10.5435/00124635-200808000-00003 ↗
11. Revision of tibial TKA components: bone loss is independent of cementing type and technique: an in vitro cadaver study10.1186/1471-2474-12-6 ↗
12. Biomechanics and pathomechanisms of osteoarthritis
13. Implantation of customized 3-D printed titanium prosthesis in limb salvage surgery : a case series and review of the literature
14. In vitro assessments of reverse glenoid stability using displacement gages are misleading - recommendations for accurate measurements of interface micromotion10.1016/j.clinbiomech.2011.05.002 ↗
15. Revision of failed cementless total knee implants with cement10.1097/00003086-199811000-00007 ↗
16. Biological fixation of endosseous implants10.1016/j.micron.2005.05.010 ↗
17. Survival and clinical function of cemented and uncemented prostheses in total knee replacement: a META-analysis10.1302/0301-620X.91B7.21702 ↗
18. In vivo loss of cement-bone interlock reduces fixation strength in total knee arthroplasties10.1002/jor.22634 ↗
19. Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up10.1007/s00402-011-1330-5 ↗
20. Metaphyseal fixation in revision total knee arthroplasty: indications and techniques10.5435/00124635-201106000-00001 ↗
21. Complex primary and revision total knee arthroplasty using the condylar constrained prosthesis: an average 5-year follow-up10.1016/S0883-5403(98)90002-X ↗
22. Hosein
23. Patient-specific 3-dimensional printed titanium truss cage with tibiotalocalcaneal arthrodesis for salvage of persistent distal tibia nonunion10.1177/1938640015593079 ↗
24. In vivo skeletal responses to porous-surfaced implants subjected to small induced motions10.2106/00004623-199705000-00010 ↗
25. Damage accumulation, fatigue and creep behaviour of vacuum mixed bone cement10.1016/j.biomaterials.2005.02.009 ↗
26. Revision total knee arthroplasty with the use of trabecular metal cones. A randomized radiostereometric analysis with 2 Years of follow-up10.1016/j.arth.2012.04.036 ↗
27. Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis: a follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register10.3109/17453674.2010.501747 ↗
28. The epidemiology of failure in total knee arthroplasty
29. Sacral reconstruction with a 3D-printed implant after hemisacrectomy in a patient with sacral osteosarcoma: 1-year follow-up result10.3349/ymj.2017.58.2.453 ↗
30. Analysis of stem tip pain in revision total knee arthroplasty10.1016/j.arth.2012.10.007 ↗
31. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
32. Peri-implant bone strains and micro-motion following in vivo service: a postmortem retrieval study of 22 tibial components from total knee replacements10.1002/jor.22534 ↗
33. Long-term results of total knee arthroplasty in young and active patients with posterior stabilized design10.1016/j.knee.2015.10.008 ↗
34. Zonal fixation in revision total knee arthroplasty10.1302/0301-620X.97B2.34144 ↗
35. Bone loss management in total knee revision surgery10.1007/s00264-013-2262-1 ↗
36. Cranioplasty enhanced by three-dimensional printing10.1097/SCS.0000000000002656 ↗
37. Peters · 2001 · 84132
38. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses10.1302/0301-620X.77B3.7744919 ↗
39. Bone loss in revision total knee arthroplasty10.5435/JAAOS-D-15-00660 ↗
40. Stress and strain analysis of the bone-implant interface: a comparison of fiber-reinforced composite and titanium implants utilizing 3-dimensional finite element study10.1563/AAID-JOI-D-09-00046 ↗
41. Micromotion at the tibial plateau in primary and revision total knee arthroplasty: fixed versus rotating platform designs10.1302/2046-3758.54.2000481 ↗
42. The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip10.1302/0301-620X.89B4.18055 ↗
43. Cementing the tibial component in total knee arthroplasty. Which technique is the best?10.1016/j.arth.2010.01.107 ↗
44. Cemented long-stem revision total knee arthroplasty10.1016/S0883-5403(03)00200-6 ↗
45. The management of bone loss in revision total knee replacement10.1302/0301-620X.90B8.19948 ↗
46. Digital image correlation technique10.1016/j.optlaseng.2014.07.010 ↗
47. Reconstruction of the upper cervical spine using a personalized 3D-printed vertebral body in an adolescent with ewing sarcoma10.1097/BRS.0000000000001179 ↗