journal article·2017-01

Mechanical response of 3D Insert® PCL to compression

M. Brunelli, C.M. Perrault, D. Lacroix

Publisher page

Abstract

3D polymeric scaffolds are increasingly used for in vitro experiments aiming to mimic the environment found in vivo, to support for cellular growth and to induce differentiation through the application of external mechanical cues. In research, experimental results must be shown to be reproducible to be claimed as valid and the first clause to ensure consistency is to provide identical initial experimental conditions between trials. As a matter of fact, 3D structures fabricated in batch are supposed to present a highly reproducible geometry and consequently, to give the same bulk response to mechanical forces. This study aims to measure the overall mechanical response to compression of commercially available 3D Insert PCL scaffolds (3D PCL) fabricated in series by fuse deposition and evaluate how small changes in the architecture of scaffolds affect the mechanical response. The apparent elastic modulus (Ea) was evaluated by performing quasi-static mechanical tests at various temperatures showing a decrease in material stiffness from 5MPa at 25°C to 2.2MPa at 37°C. Then, a variability analysis revealed variations in Ea related to the repositioning of the sample into the testing machine, but also consistent differences comparing different scaffolds. To clarify the source of the differences measured in the mechanical response, the same scaffolds previously undergoing compression, were scanned by micro computed tomography (μCT) to identify any architectural difference. Eventually, to clarify the contribution given by differences in the architecture to the standard deviation of Ea, their mechanical response was qualitatively compared to a compact reference material such as polydimethylsiloxane (PDMS). This study links the geometry, architecture and mechanical response to compression of 3D PCL scaffolds and shows the importance of controlling such parameters in the manufacturing process to obtain scaffolds that can be used in vitro or in vivo under reproducible conditions.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies · 3D Printing in Biomedical Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Properties of thermoplastic blends: starch-polycaprolactone10.1016/S0032-3861(99)00636-9 ↗
2. The inter-sample structural variability of regular tissue-engineered scaffolds significantly affects the micromechanical local cell environment10.1098/rsfs.2014.0097 ↗
3. Chasin · 1990
4. Scaffold design for tissue engineering10.1002/1616-5195(20020201)2:2<67::AID-MABI67>3.0.CO;2-F ↗
5. Additive manufacturing in biomedical sciences and the need for definitions and norms10.1586/17434440.2015.1059274 ↗
6. Material properties in unconfined compression of human nucleus pulposus, injectable hyaluronic acid-based hydrogels and tissue engineering scaffolds10.1007/s00586-007-0443-6 ↗
7. Matrix elasticity directs stem cell lineage specification10.1016/j.cell.2006.06.044 ↗
8. Hopkinson bar experimental technique: a critical review10.1115/1.1704626 ↗
9. Dynamic mechanical behavior of starch-based scaffolds in dry and physiologically simulated conditions: effect of porosity and pore size10.1016/j.actbio.2008.02.001 ↗
10. Gibson, L.J., Ashby, M.F., Cellular Solids: Structure and Properties. 1999.
11. Porous scaffold design for tissue engineering10.1038/nmat1421 ↗
12. Fabrication using a rapid prototyping system and in vitro characterization of PEG-PCL-PLA scaffolds for tissue engineering10.1163/156856205774576709 ↗
13. Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling10.1002/1097-4636(200105)55:2<203::AID-JBM1007>3.0.CO;2-7 ↗
14. Biomechanical model to simulate tissue differentiation and bone regeneration: application to fracture healing10.1007/BF02347690 ↗
15. Dynamics of in vitro polymer degradation of polycaprolactone-based scaffolds: accelerated versus simulated physiological conditions10.1088/1748-6041/3/3/034108 ↗
16. Evaluation of polycaprolactone scaffold degradation for 6 months in vitro and in vivo10.1002/jbm.a.32052 ↗
17. Landel · 1993
18. Regulatory considerations in the design and manufacturing of implantable 3D-printed medical devices10.1111/cts.12315 ↗
19. Aliphatic polyesters II. The degradation of poly (DL-lactide), poly (ε-caprolactone), and their copolymers in vivo10.1016/0142-9612(81)90060-0 ↗
20. In vivo efficacy of bone-marrow-coated polycaprolactone scaffolds for the reconstruction of orbital defects in the pig10.1002/jbm.b.10037 ↗
21. Cranioplasty after trephination using a novel biodegradable burr hole cover: technical case report
22. Three-dimensional plotted scaffolds with controlled pore size gradients: Effect of scaffold geometry on mechanical performance and cell seeding efficiency10.1016/j.actbio.2010.11.003 ↗
23. In vitro generation of mechanically functional cartilage grafts based on adult human stem cells and 3D-woven poly(ɛ-caprolactone) scaffolds10.1016/j.biomaterials.2009.11.092 ↗
24. Ward · 2012
25. Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering10.1016/j.biomaterials.2004.11.057 ↗
26. Mechano-active scaffold design based on microporous poly (L-lactide-co-ε-caprolactone) for articular cartilage tissue engineering: dependence of porosity on compression force-applied mechanical behaviors10.1089/ten.2006.12.449 ↗
27. The degradation profile of novel, bioresorbable PCL – TCP scaffolds: an in vitro and in vivo study10.1002/jbm.a.31454 ↗
28. 3D plotted PCL scaffolds for stem cell based bone tissue engineering10.1002/masy.200850911 ↗
29. Crosslinking of poly(epsilon-caprolactone) by radiation technique and its biodegradability10.1016/S0969-806X(99)00449-1 ↗