On the wear behavior and damage mechanism of bonded interface: Ceramic vs resin composite inlays
Source abstract
Abstract
Advances in adhesive technologies have increased indications for the use of inlays. Decrease in the bonded interface integrity due to wear has been cited as the main cause of its failure. However, this process of interface degradation and the influence of inlay material on damage mechanism appear to be poorly understood. Thus, we aimed to compare the wear behavior and interface damage between ceramic and resin composite inlays bonded to enamel under sliding contact and use the experimental findings to support recommendation of the appropriate inlay material. Bonded interface specimens involving tooth enamel and either ceramic or resin composite inlays were prepared and subjected to reciprocating wear tests up to 5×104 cycles. The wear track profiles and morphologies were characterized after increments of cyclic sliding contact using white light interferometry and scanning electron microscopy, respectively. Optical microscopy was used to evaluate sub-surface cracks and their propagation within the samples. A finite element analysis was used to analyze the stress distributions of the bonded interfaces. Composite inlays showed higher wear depth than the ceramic in the early stage (N ≤ 5×102 cycles), while no significant difference was found at the later stage. For ceramic inlay a greater portion of the contact load was concentrated in the ceramic structure, which facilitated cracks and chipping of the ceramic inlay, with rather minimal damage in the adjacent interface and enamel. In contrast, for the resin composite inlay there was larger stress concentrated in the adjacent enamel, which caused the development of cracks and their propagation to the inner enamel. The restoration material could contribute to the stress distribution and extent of damage within enamel-inlay bonded interfaces. A tough ceramic appears to be more effective at protecting the residual dental tissue.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. CAD-FE modeling and analysis of class II restorations incorporating resin-composite, glass ionomer and glass ceramic materials10.1016/j.dental.2017.10.010 ↗
2. Stress distributions in adhesively cemented ceramic and resin-composite Class II inlay restorations: a 3D-FEA study10.1016/j.dental.2004.05.001 ↗
3. The effect of base materials with different elastic moduli on the fracture loads of machinable ceramic inlays10.2341/05-3 ↗
4. Effect of hybrid layer on stress distribution in a premolar tooth restored with composite or ceramic inlay: an FEM study10.1002/jbm.b.30181 ↗
5. In vitro wear gap formation of self-adhesive resin cements: a CLSM evaluation10.1016/j.jdent.2009.08.006 ↗
6. The influence of elastic modulus of inlay materials on stress distribution and fracture of premolars10.2341/13-092-L ↗
7. Fracture resistance of resin-based composite and ceramic inlays luted to sound human teeth
8. Elastic properties of lithium disilicate versus feldspathic inlays: effect on the bonding by 3D finite element analysis10.1111/jopr.12550 ↗
9. Leucite-reinforced glass ceramic inlays and onlays after 12 years
10. Clinical efficacy of composite versus ceramic inlays and onlays: a systematic review10.1016/j.dental.2013.09.009 ↗
11. Mechanical properties and sliding-impact wear resistance of self-adhesive resin cements10.2341/15-033-L ↗
12. Composite inlays: a systematic review
13. Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue10.1016/j.jdent.2013.10.002 ↗
14. Ceramics as biomaterials for dental restoration10.1586/17434440.5.6.729 ↗
15. Fracture risk of lithium-disilicate ceramic inlays: a finite element analysis10.1016/j.dental.2013.09.012 ↗
16. Marginal and internal fit of pressed lithium disilicate inlays fabricated with milling, 3D printing, and conventional technologies10.1016/j.prosdent.2017.07.025 ↗
17. Surface roughness and wear of resin cements after toothbrush abrasion10.1590/1807-3107BOR-2015.vol29.0011 ↗
18. Lifetime-limiting strength degradation from contact fatigue in dental ceramics10.1177/00220345000790020501 ↗
19. Effect of gap dimension on composite resin cement wear
20. Cyclic mechanical loading promotes bacterial penetration along composite restoration marginal gaps10.1016/j.dental.2015.03.011 ↗
21. Clinical performance of bonded leucite-reinforced glass ceramic inlays and onlays after eight years10.1016/j.dental.2004.03.009 ↗
22. Ceramic inlays bonded with two adhesives after 4 years10.1016/j.dental.2005.02.013 ↗
23. Marginal quality and wear of extended posterior resin composite restorations: eight-year results in vivo10.1016/j.jmbbm.2015.05.018 ↗
24. Adhesive luting of indirect restorations
25. Totally bonded ceramic inlays and onlays after eight years
26. The influence of antagonist standardization on wear10.1177/00220345990780021201 ↗
27. A comparison of fatigue resistance of three materials for cusp-replacing adhesive restorations10.1016/j.jdent.2005.02.010 ↗
28. Clinical evaluation of ceramic inlays compared to composite restorations10.2341/08-95 ↗
29. An analysis of the physiologic parameters of intraoral wear: a review10.1088/0022-3727/46/40/404007 ↗
30. Efficient 3D finite element analysis of dental restorative procedures using micro-CT data10.1016/j.dental.2006.03.013 ↗
31. Porcelain versus composite inlays/onlays: effects of mechanical loads on stress distribution, adhesion, and crown flexure
32. Three-year clinical evaluation of composite and ceramic inlays
33. Dynamic visco-elastic properties of dental composite resins10.1016/j.dental.2005.04.019 ↗
34. Survival rate of resin and ceramic inlays, onlays, and overlays: a systematic review and meta-analysis10.1177/0022034516652848 ↗
35. Nanotechnology for dental composites10.1504/IJNT.2004.003723 ↗
36. Cracks formed by Vickers indentation adjacent to the interface in bonded dental ceramics with various marginal angles10.4012/dmj.2010-115 ↗
37. The effect of temperature on the viscoelastic properties of nano-hybrid composites10.1016/j.dental.2007.05.009 ↗
38. Stress distribution in a post‐restored tooth using the three‐dimensional finite element method10.1111/j.1365-2842.2006.01538.x ↗
39. Eight-year clinical evaluation of a 2-step self-etch adhesive with and without selective enamel etching10.1016/j.dental.2010.08.190 ↗
40. Two-year clinical evaluation of a self-adhesive luting agent for ceramic inlays10.1007/s00784-012-0762-9 ↗
41. A systematic review of ceramic inlays in posterior teeth: an update
42. Marginal fit of indirect composite inlays using a new system for manual fabrication
43. Effect of toothbrushing abrasion on weight and surface roughness of pH-cycled resin cements and indirect restorative materials
44. Clinical evaluation of ceramic inlays and onlays fabricated with two systems: 12-year follow-up10.1007/s00784-015-1669-z ↗
45. Biomechanics of cervical tooth region and noncarious cervical lesions of different morphology; three-dimensional finite element analysis
46. Effect of material and fabrication technique on marginal fit and fracture resistance of adhesively luted inlays made of CAD/CAM ceramics and hybrid materials10.1080/01694243.2016.1204144 ↗
47. Fatigue load of teeth restored with bonded direct composite and indirect ceramic inlays in MOD class II cavity preparations
48. Fracture resistance of teeth restored with indirect-composite and ceramic inlay systems
49. Fracture resistance of prepared teeth restored with bonded inlay restorations10.1016/S0022-3913(03)00173-2 ↗
50. Simulated wear of self-adhesive resin cements10.2341/14-227-L ↗
51. Ultrasonic measurement of the effects of light irradiation and presence of water on the polymerization of self‐adhesive resin cement10.1111/eos.12205 ↗
52. Evaluation of fracture resistance and failure risks of posterior partial coverage restorations10.1111/jerd.12018 ↗
53. A 5-year clinical study of indirect and direct resin composite and ceramic inlays
54. Dynamic and static mechanical analysis of resin luting cements10.1016/j.jmbbm.2011.10.002 ↗
55. Influence of filler content and gap dimension on wear resistance of resin composite luting cements around a CAD/CAM ceramic inlay restoration10.4012/dmj.18.453 ↗
56. Chairside CAD/CAM materials. Part 2: flexural strength testing10.1016/j.dental.2016.10.008 ↗
57. Wear measurement of dental tissues and materials in clinical studies: a systematic review10.1016/j.dental.2018.03.002 ↗
58. Wear and damage at the bonded interface between tooth enamel and resin composite10.1016/j.jdent.2019.02.004 ↗
59. A comparative study on the wear behavior of a polymer infiltrated ceramic network (PICN) material and tooth enamel10.1016/j.dental.2017.08.190 ↗
60. Effects of different ceramic and composite materials on stress distribution in inlay and onlay cavities: 3-D finite element analysis10.4012/dmj.28.661 ↗
61. Wear behavior of new composite restoratives
62. Effect of acidic agents on the wear behavior of a polymer infiltrated ceramic network (PICN) material10.1016/j.jmbbm.2017.06.001 ↗