Impact of tibial baseplate malposition on kinematics, contact forces and ligament tensions in TKA: A numerical analysis
Source abstract
Abstract
PURPOSE: Malposition of implant components in total knee arthroplasty (TKA) has consequences on tibiofemoral kinematics, contact forces and ligament tensions. To evaluate the impact of tibial baseplate malpositioning in the same knee, we conducted a computer simulation. METHODS: An established weight-bearing finite element model of a fixed bearing TKA was used for the computer simulation. To evaluate the influence of tibial baseplate malposition, calculations were consecutively performed in neutral position, at 3° and 6° of internal and external rotation and at 3 mm and 6 mm of medial and lateral translation. RESULTS: The highest effect of malposition was observed for ligament tensions, with a tendency of a greater influence for the 6 mm translation compared to 6° of rotation. Changes in contact forces and tibiofemoral kinematics were according to the alterations of ligament tensions. The highest ligament tension, contact force and femoral roll-back were registered for 6 mm medialization of the tibial baseplate. DISCUSSION: Tibial baseplate malposition effects ligament tensions, tibiofemoral contact forces and kinematics and has a risk of unfavorable clinical results due to postoperative pain, reduced range of motion, instability and a higher rate of early loosening. Therefore, surgeons should aim for a neutral position of the tibial baseplate.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Functional outcome and patient satisfaction in total knee patients over the age of 7510.1016/S0883-5403(96)80183-5 ↗
2. Internal rotation of the tibial component is frequent in stiff total knee arthroplasty10.1007/s11999-011-1889-8 ↗
3. Oversizing the tibial component in TKAs: incidence, consequences and risk factors10.1007/s00167-015-3512-0 ↗
4. Mediolateral oversizing influences pain, function, and flexion after TKA10.1007/s00167-013-2443-x ↗
5. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?10.1007/s11999-009-1119-9 ↗
6. Bryan · 2018 · vol. 19 · 423
7. Patient satisfaction after total knee arthroplasty10.5792/ksrr.2016.28.1.1 ↗
8. Anteroposterior positioning of the tibial component and its effect on the mechanics of patellofemoral contact10.1302/0301-620X.92B10.24221 ↗
9. The movement of the normal tibio-femoral joint10.1016/j.jbiomech.2004.02.006 ↗
10. Retropatellar contact characteristics before and after total knee arthroplasty10.1016/S0968-0160(02)00045-5 ↗
11. Medial stabilized and posterior stabilized TKA affect patellofemoral kinematics and retropatellar pressure distribution differently10.1007/s00167-017-4772-7 ↗
12. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients10.1007/s00167-012-2220-2 ↗
13. Contact forces in several TKA designs during squatting: a numerical sensitivity analysis10.1016/j.jbiomech.2011.02.081 ↗
14. What differences in morphologic features of the knee exist among patients of various races? A systematic review10.1007/s11999-016-5097-4 ↗
15. The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis10.1007/s00264-013-2097-9 ↗
16. Malrotated tibial component increases medial collateral ligament tension in total knee arthroplasty10.1002/jor.22711 ↗
17. Patients with no functional improvement after total knee arthroplasty show different kinematics10.1007/s00264-012-1584-8 ↗
18. Instability after total knee arthroplasty10.1055/s-0034-1396080 ↗
19. Internal rotational error of the tibial component is a major cause of pain after total knee replacement10.1302/0301-620X.92B9.23516 ↗
20. Overgaard · 2019 · 1
21. Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study10.1016/j.jbiomech.2012.06.014 ↗
22. Knee kinetics and kinematics: what are the effects of TKA malconfigurations?10.1007/s00167-015-3514-y ↗
23. Does the femur roll-back with flexion?10.1302/0301-620X.86B6.14589 ↗
24. Sutured tendon repair; a multi-scale finite element model10.1007/s10237-014-0593-5 ↗
25. Revision surgery after total joint arthroplasty: a complication-based analysis using worldwide arthroplasty registers10.1016/j.arth.2013.01.012 ↗
26. The influence of deceleration forces on ACL strain during single-leg landing: a simulation study10.1016/j.jbiomech.2006.05.004 ↗
27. Effect of tibial component varus on wear in total knee arthroplasty10.1016/j.knee.2011.11.003 ↗
28. Influence of mediolateral tibial baseplate position in TKA on knee kinematics and retropatellar pressure10.1007/s00167-015-3843-x ↗
29. The effect of trochlea tilting on patellofemoral contact patterns after total knee arthroplasty: an in vitro study10.1007/s00402-014-1956-1 ↗
30. Femorotibial kinematics and load patterns after total knee arthroplasty: an in vitro comparison of posterior-stabilized versus medial-stabilized design10.1016/j.clinbiomech.2016.02.002 ↗
31. Influence of tibial rotation in total knee arthroplasty on knee kinematics and retropatellar pressure: an in vitro study10.1007/s00167-015-3503-1 ↗
32. Mediolateral femoral component position in TKA significantly alters patella shift and femoral roll-back10.1007/s00167-017-4633-4 ↗
33. Posterior cruciate ligament balancing in total knee arthroplasty: a numerical study with a dynamic force controlled knee model10.1186/1475-925X-13-91 ↗
34. Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty: a Finite Element Analysis10.1302/2046-3758.611.BJR-2016-0088.R2 ↗
35. How exactly can computer simulation predict the kinematics and contact status after TKA? Examination in individualized models10.1016/j.clinbiomech.2016.09.006 ↗
36. Biomechanical effects of total knee arthroplasty component malrotation: a computational simulation10.1002/jor.21344 ↗
37. Reason for revision TKA predicts clinical outcome: prospective evaluation of 150 consecutive patients with 2-years followup10.1007/s11999-013-2940-8 ↗
38. How precise can bony landmarks be determined on a CT scan of the knee?10.1016/j.knee.2009.01.001 ↗
39. Why knees fail10.1054/arth.2003.50102 ↗
40. TKA design-integrated trochlea groove rotation reduces patellofemoral pressure
41. Development and validation of a weight-bearing finite element model for total knee replacement10.1080/10255842.2015.1089534 ↗
42. Calculation of the elastic properties of prosthetic knee components with an iterative finite element-based modal analysis: quantitative comparison of different measuring techniques10.1515/bmt-2013-0003 ↗
43. Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences10.1016/j.clinbiomech.2005.03.014 ↗