The effect of different interference fits on the primary fixation of a cementless femoral component during experimental testing
Source abstract
Abstract
Cementless femoral total knee arthroplasty (TKA) components use a press-fit (referred to as interference fit) to achieve initial fixation. A higher interference fit could lead to a superior fixation, but it could also introduce more damage to the bone during implantation. The purpose of the current study was to investigate the effect of interference fit on the micromotions and gap opening/closing at the bone-implant interface. Experimental tests were performed in six pairs of cadaveric femurs implanted with femoral components using a low interference fit of 350 μm and a high interference fit of 700 μm. The specimens were subjected to the peak loads of gait and squat, based on the Orthoload dataset. Digital Image Correlation (DIC) was used to measure the micromotions and opening/closing in different regions of interest (ROIs). Two linear mixed-effect statistical models were created with micromotions and gap opening/closing as dependent variables. ROIs, loading conditions, and implant designs as independent variables, and cadaver specimens as random intercepts. The results revealed no significant difference between the two interference fit implants for micromotions (p = 0.837 for gait and p = 0.065 for squat), nor for the gap opening/closing (p = 0.748 for gait and p = 0.561 for squat). In contrast, significant differences were found between loading and most of the ROIs in both dependent variables (p < 0.0001). Additionally, no difference in bone deformation was found between low and high interference fit. Changing interference between either 350 μm or 700 μm did not affect the primary stability of a femoral TKA component. There could be an interference fit threshold beyond which fixation does not further improve.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Finite element modelling of primary hip stem stability: the effect of interference fit10.1016/j.jbiomech.2007.10.009 ↗
2. Evaluation of interference fit and bone damage of an uncemented femoral knee implant10.1016/j.clinbiomech.2017.10.022 ↗
3. Experimental pre-clinical assessment of the primary stability of two cementless femoral knee components10.1016/j.jmbbm.2017.07.043 ↗
4. FE analysis of the effects of simplifications in experimental testing on micromotions of uncemented femoral knee implants10.1002/jor.23074 ↗
5. Bergmann · 2008
6. Optimal interference of the tibial component of the cementless oxford unicompartmental knee replacement10.1302/2046-3758.73.BJR-2017-0193.R1 ↗
7. Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: more than 5- Year Follow-Up of the e.motion ((®)) UC-TKA10.2174/1874325001307010152 ↗
8. Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions10.1016/j.jbiomech.2009.12.006 ↗
9. Quantification of interfacial motions following primary and revision total knee Arthroplasty : a verification study versus experimental data10.1002/jor.23653 ↗
10. Long-term implant-bone fixation of the femoral component in total knee replacement10.1243/09544119JEIM328 ↗
11. Friction coefficient and effective interference at the implant-bone interface10.1016/j.jbiomech.2015.07.012 ↗
12. The future of biologic coatings for orthopaedic implants10.1016/j.biomaterials.2013.01.074 ↗
13. Simultaneous and multisite measure of micromotion, subsidence and gap to evaluate femoral stem stability10.1016/j.jbiomech.2012.01.040 ↗
14. Influence of limb alignment on mediolateral loading in total knee replacement10.2106/JBJS.K.00927 ↗
15. Implant fixation by bone ingrowth10.1016/S0883-5403(99)90063-3 ↗
16. Mediolateral force distribution at the knee joint shifts across activities and is driven by tibiofemoral alignment10.1302/0301-620X.99B6.BJJ-2016-0713.R1 ↗
17. Comparison of cementless and hybrid cemented total knee arthroplasty10.3928/01477447-20130327-16 ↗
18. Cementless total knee arthroplasty in patients older than 75 years10.1055/s-0037-1599253 ↗
19. Subject specific finite element analysis of implant stability for a cementless femoral stem10.1016/j.clinbiomech.2009.03.009 ↗
20. Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation10.1016/j.jmbbm.2019.04.054 ↗
21. The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis10.1080/10255842.2012.662677 ↗
22. Micromotion analysis of the fixation of total knee tibial component10.1016/0045-7949(95)00029-G ↗
23. Cementless total knee arthroplasty: patient selection and surgical techniques to optimize outcomes10.1053/j.sart.2018.04.003 ↗