journal article·2022-01

Computational analysis of the effects of geometric irregularities on the interaction of an additively manufactured 316L stainless steel stent and a coronary artery

Lisa Wiesent, Ashley Spear, Aida Nonn

Publisher page

Abstract

Customized additively manufactured (laser powder bed fused (L-PBF)) stents could improve the treatment of complex lesions by enhancing stent-artery conformity. However, geometric irregularities inherent for L-PBF stents are expected to influence not only their mechanical behavior but also their interaction with the artery. In this study, the influence of geometrical irregularities on stent-artery interaction is evaluated within a numerical framework. Thus, computed arterial stresses induced by a reconstructed L-PBF stent model are compared to those induced by the intended stent model (also representing a stent geometry obtained from conventional manufacturing processes) and a modified CAD stent model that accounts for the increased strut thickness inherent for L-PBF stents. It was found that, similar to conventionally manufactured stents, arterial stresses are initially related to the basic stent design/topology, with the highest stresses occurring at the indentations of the stent struts. Compared to the stent CAD model, the L-PBF stent induces distinctly higher and more maximum volume stresses within the plaque and the arterial wall. In return, the modified CAD model overestimates the arterial stresses induced by the L-PBF stent due to its homogeneously increased strut thickness and thus its homogeneously increased geometric stiffness compared with the L-PBF stent. Therefore, the L-PBF-induced geometric irregularities must be explicitly considered when evaluating the L-PBF stent-induced stresses because the intended stent CAD model underestimates the arterial stresses, whereas the modified CAD model overestimates them. The arterial stresses induced by the L-PBF stent were still within the range of values reported for conventional stents in literature, suggesting that the use of L-PBF stents is conceivable in principle. However, because geometric irregularities, such as protruding features from the stent surface, could potentially damage the artery or lead to premature stent failure, further improvement of L-PBF stents is essential.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Tribology and Lubrication Engineering · Elasticity and Material Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Stent fracture in the coronary and peripheral arteries10.1111/j.1540-8183.2010.00567.x ↗
2. Carotid artery stenting simulation: From patient-specific images to finite element analysis10.1016/j.medengphy.2010.10.011 ↗
3. Effects of different stent designs on local hemodynamics in stented arteries10.1016/j.jbiomech.2007.12.005 ↗
4. Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing10.1016/j.matdes.2013.01.071 ↗
5. Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometry10.1016/j.medengphy.2008.11.002 ↗
6. Effects of stent sizing on endothelial and vessel wall stress: Potential mechanisms for in-stent restenosis10.1152/japplphysiol.91519.2008 ↗
7. Modelling of atherosclerotic plaque for use in a computational test-bed for stent angioplasty10.1007/s10439-014-1107-4 ↗
8. A computational test-bed to assess coronary stent implantation mechanics using a population-specific approach10.1007/s13239-012-0104-8 ↗
9. Dassault Systemes · 2013 · 1138
10. Realistic finite element-based stent design: The impact of balloon folding10.1016/j.jbiomech.2007.08.014 ↗
11. Additive manufacturing of cardiovascular CoCr stents by selective laser melting10.1016/j.matdes.2017.01.091 ↗
12. Numerical simulation of stent deployment within patient-specific artery and its validation against clinical data10.1016/j.cmpb.2019.04.005 ↗
13. Study of size effect on microstructure and mechanical properties of AlSi10Mg samples made by selective laser melting10.3390/ma11122463 ↗
14. Design rules for producing cardiovascular stents by selective laser melting: Geometrical constraints and opportunities10.1016/j.prostr.2019.07.004 ↗
15. Design and functional testing of a novel balloon-expandable cardiovascular stent in CoCr alloy produced by selective laser melting10.1016/j.jmapro.2020.03.060 ↗
16. Finite element modeling of manufacturing irregularities of porous materials
17. Acute and chronic tissue response to coronary stent implantation: Pathologic findings in human specimen10.1016/S0735-1097(99)00486-6 ↗
18. Comparing coronary stent material performance on a common geometric platform through simulated bench testing10.1016/j.jmbbm.2012.02.013 ↗
19. Compressive behaviour of stainless steel micro-lattice structures10.1016/j.ijmecsci.2013.01.006 ↗
20. Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events10.1016/S0735-1097(00)00570-2 ↗
21. Hasgall · 2018
22. Finite element evaluation of artery damage in deployment of polymeric stent with pre- and post-dilation10.1007/s10237-019-01194-6 ↗
23. Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling10.1152/ajpheart.00934.2004 ↗
24. Drug-eluting stent: A review and update10.2147/vhrm.2005.1.4.263 ↗
25. Effect of selective laser melting on microstructure, mechanical, and corrosion properties of biodegradable FeMnCS for implant applications
26. Direct coronary stent implantation does not reduce the incidence of in-stent restenosis or major adverse cardiac events: Six month results of a randomized trial10.1016/S0195-668X(02)00701-7 ↗
27. A computationally efficient modeling approach for predicting mechanical behavior of cellular lattice structures10.1007/s11665-014-1281-4 ↗
28. Restenosis after coronary placement of various stent types10.1016/S0002-9149(00)01268-6 ↗
30. Impact of stent-to-vessel diameter ratio on restenosis in the superficial femoral artery after endovascular therapy10.1253/circj.CJ-17-0726 ↗
31. Lapp · 2019
32. Bifurcation disease: What do we know, what should we do?10.1016/j.jcin.2007.12.008 ↗
33. Evaluation of compressive properties of SLM-fabricated multi-layer lattice structures by experimental test and μ-CT-based finite element analysis10.1016/j.matdes.2019.107685 ↗
34. Effective and efficient strategies for coronary revascularization in the drug-eluting stent era
35. Elastic and failure response of imperfect three-dimensional metallic lattices: The role of geometric defects induced by selective laser melting10.1016/j.jmps.2017.07.003 ↗
36. Static circumferential tangential modulus tissue10.1016/0021-9290(94)90209-7 ↗
37. Lattice structures and functionally graded materials applications in additive manufacturing of orthopedic implants: A review
38. Patient-specific simulations of stenting procedures in coronary bifurcations: Two clinical cases10.1016/j.medengphy.2013.01.007 ↗
39. Nandishwarsteel · 2010
40. Large deformation isotropic elasticity: On the correlation of theory and experiment for compressible rubberlike solids
41. A design for the additive manufacture of functionally graded porous structures with tailored mechanical properties for biomedical applications10.1016/j.jmapro.2011.01.004 ↗
42. Analysis of prolapse in cardiovascular stents: A constitutive equation for vascular tissue and finite-element modelling10.1115/1.1613674 ↗
43. Measurement of density and calcium in human atherosclerotic plaque and implications for arterial brachytherapy10.1016/S1522-1865(00)00030-5 ↗
44. Effects of material , coating , design and plaque composition on stent deployment inside a stenotic artery — Finite element simulation10.1016/j.msec.2014.05.057 ↗
45. Coronary-artery stents10.1056/NEJMra051091 ↗
46. Effect of endothelial shear stress on the progression of coronary artery disease, vascular remodeling, and in-stent restenosis in humans: In vivo 6-month follow-up study10.1161/01.CIR.0000080882.35274.AD ↗
47. Mechanical modeling of stents deployed in tapered arteries10.1007/s10439-008-9582-0 ↗
48. Increased artery wall stress post-stenting leads to greater intimal thickening10.1038/labinvest.2011.57 ↗
49. Structural and hemodynamic analyses of different stent structures in curved and stenotic coronary artery
50. Computational analysis of the effects of geometric irregularities and post-processing steps on the mechanical behavior of additively manufactured 316L stainless steel stents10.1371/journal.pone.0244463 ↗
51. Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning10.1371/journal.pone.0224026 ↗
52. Delivery and release of nitinol stent in carotid artery and their interactions: A finite element analysis10.1016/j.jbiomech.2007.02.024 ↗
53. Determination of the influence of stent strut thickness using the finite element method: Implications for vascular injury and in-stent restenosis10.1007/s11517-009-0432-5 ↗