Mobile or fixed unicompartmental knee prostheses? In-vitro wear assessments to solve this dilemma
Source abstract
Abstract
The unicompartmental knee prosthesis is an attractive alternative to total knee arthroplasty. Current UKP devices can be subdivided into two groups based on different design principles: fixed bearing knees, where the ultra-high molecular weight polyethylene meniscal component snap or press fits into the tibial tray, and mobile bearing designs which facilitate movement of the insert relative to the tray. The present study was aimed at comparing the in-vitro wear behaviour of fixed and mobile unicompartmental knee menisci under two configurations: the femoral components were cemented into a custom-made metallic block or, as a novelty of the present study, into a synthetic femur (i.e. under conditions which should better reproduce the in-vivo behaviour). Analyses were performed using a displacement-control knee wear simulator with "three-plus-one" stations. All the kinematics tests were set in accordance with the ISO 14243-1,2,3. Fixed and mobile polyethylene menisci showed a different wear behaviour: the fixation-frame influenced directional load transfer through each component in a qualitative and quantitative way. In fact, gravimetric results showed that under the metal block holder fixation, mobile components worn more than fixed components (weight losses of 8.7±2.0 mg and 2.6±1.09 mg, respectively); on the other hand, under the synthetic femur configuration, differences in wear behaviour were less pronounced and mobile menisci underwent a slightly lower weight loss than fixed components (4.5±2.2 mg vs. 6.7±1.4 mg). This different trend was explained in relation to the kinematic schemes of the two fixation methods. Raman spectroscopy, used to evaluate the UHMWPE crystallinity changes induced by mechanical stress, showed that mobile menisci specimens were more affected than the fixed components in both their superior and inferior surfaces, independent of the fixation-frame. In conclusion, if tested under conditions which should better reproduce the in-vivo behaviour, mobile UKPs did not show a worse wear behaviour than fixed components in terms of weight losses, although UHMWPE changes at the molecular scale could be detrimental.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Fermi resonances and vibrational-spectra of amorphous polymethylene chains10.1021/j100213a017 ↗
2. The performancee of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols10.1016/S0142-9612(03)00264-3 ↗
3. A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement10.1111/j.1525-1594.2008.00656.x ↗
4. Unicompartmental knee prostheses: in vitro wear assessment of the menisci tibial insert after two different fixation methods10.1088/0031-9155/53/19/006 ↗
5. Can the method of fixation influence the wear behaviour of Zrn coated unicompartmental mobile knee prostheses?10.1016/j.clinbiomech.2010.09.010 ↗
6. Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups10.1243/0954411011533463 ↗
7. Polyethylene wear in meniscal knee replacement: a one to nine year retrieval analysis of the Oxford knee10.1302/0301-620X.74B2.1544958 ↗
8. Kolmogorov–Smirnov Test
9. Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis10.1016/j.knee.2004.03.004 ↗
10. Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements10.1007/s00167-004-0565-x ↗
11. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement10.2106/00004623-198668070-00010 ↗
12. Micro-Raman spectroscopy for the crystallinity characterization of UHMWPE hip cups run on joint simulators10.1016/S0022-2860(99)00427-5 ↗
13. Unicompartmental replacement and high tibial osteotomy for osteoarthritis of the knee: a comparative study after 5–10 years’ followup10.1302/0301-620X.68B3.3733813 ↗
14. Mobile-bearing knee replacement — concept and results
15. Shelf age of the polyethylene tibial component and outcome of unicondylar knee arthroplasty10.2106/00004623-200404000-00014 ↗
16. Factors associated with the lossof thickness of polyethylene tibial bearings after knee arthroplasty10.2106/00004623-200706000-00020 ↗
17. Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss
18. Bi-compartmental vs. total knee arthroplasty: a matched paired study with early clinical results
19. Comparison of a mobile with a fixed tibial bearing unicompartimental knee prosthesis: a prospective randomized trial using a dedicated outcome score10.1016/j.knee.2004.01.003 ↗
20. Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components10.1016/j.knee.2008.08.006 ↗
21. Mechanical validation of whole bone composite femur models10.1016/0021-9290(95)00084-4 ↗
22. Polyethylene contact stresses, articular congruity, and knee alignment10.1097/00003086-200111000-00029 ↗
23. Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement10.1016/S0883-5403(99)90086-4 ↗
24. Comparison of a mobile with a fixed bearing unicompartmental knee implant10.1097/00003086-200211000-00011 ↗
25. Fixed or mobile bearing unicompartmental knee replacement? A comparative cohort study10.1016/j.knee.2004.06.006 ↗
26. Fixed and mobile bearing total knee arthroplasty—Influence on wear generation, corresponding wear areas, knee kinematics and particle composition10.1016/j.clinbiomech.2008.11.006 ↗
27. Fixed or mobile-bearing total knee arthroplasty10.1186/1749-799X-2-1 ↗
28. Long-term results of low contact stress mobile-bearing total knee replacements10.1097/01.blo.0000093890.12372.46 ↗
29. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE10.1016/j.jbiomech.2007.09.005 ↗
30. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study10.1016/j.actbio.2010.09.031 ↗
31. In-depth oxidation and strain profiles in UHMWPE acetabular cups non-destructively studied by confocal Raman microprobe spectroscopy10.1163/156856208X386417 ↗
32. Chain mobility in polymer systems: on the borderline between solid and melt. 3. Phase transformations in nascent ultra high molecular weight polyethylene reactor powder at elevated pressure as revealed by in-situ Raman spectroscopy10.1021/ma9911187 ↗
33. Strain in UHMWPE for orthopaedic use studied by Raman microprobe spectroscopy10.1163/156856207779116685 ↗
34. Unicompartmental tibiofemoral resurfacing arthroplasty10.2106/00004623-197860020-00007 ↗
35. Unicompartmental knee replacement. Some unanswered questions10.1097/00003086-200111000-00034 ↗
36. Unicompartmental versus total knee arthroplasty in the same patient. A comparative study10.1097/00003086-199112000-00023 ↗
37. Caractérisation des phases dans le polyéthylène par effet Raman10.1002/jrs.1250090309 ↗
38. The influence of design, materials and kinematics on in vitro tkr wear10.1016/j.jbiomech.2004.02.015 ↗
39. Minimally invasive unicompartmental knee replacement: rationale and correct indications10.1016/S0030-5898(03)00115-9 ↗
40. Raman spectroscopy employed for the determination of the intermediate phase in polyethylene
41. Painter, P.C., Coleman, M.M., Koenig, J.L., 1982. The theory of Vibrational Spectroscopy and its application to polymeric materials, in: Sons, J. W. (Eds.), New York.
42. Characterization of molecular-orientaiton in polyethyleen by Raman-spectroscopy10.1021/ma00020a032 ↗
43. Phase transformation in explanted highly crystalline UHMWPE acetabular cups and debris after in vivo wear10.1016/j.molstruc.2005.09.029 ↗
44. Optimization of the bearing surface geometry of total knees10.1016/0021-9290(94)90002-7 ↗
45. The effect of bearing congruency, thickness and alignment on the stresses in unicompartmental knee replacements10.1016/j.clinbiomech.2008.06.001 ↗
46. Survivorship of the St Georg Sled medial unicompartmental knee replacement beyond ten years10.1302/0301-620X.88B9.18044 ↗
47. Raman spectroscopic method for determining the crystallinity of polyethylene10.1002/pol.1978.180160704 ↗
48. The effects of irradiation and EtO-treatment on ultrahigh molecular weight polyethylene acetabular cups following accelerated ageing: degradation of mechanical properties and morphology changes during hip simulator tests10.1016/j.molstruc.2007.04.042 ↗
49. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses10.1243/PIME_PROC_1996_210_407_02 ↗
50. The causes of insert backside wear in total knee arthroplasty10.1097/00003086-200211000-00037 ↗