Electrochemical corrosion and bioactivity of Ti-Nb-Sn-hydroxyapatite composites fabricated by pulse current activated sintering
Source abstract
Abstract
Ti-Nb-Sn-hydroxyapatite (HA) composites were prepared by mechanical alloying for different times (unmilled, 4, 8 and 12h), followed by pulse current activated sintering. The effects of the milling time on the electrochemical corrosion resistance and bioactivity of the sintered Ti-35Nb-2.5Sn-15HA composites were investigated. Potentiodynamic polarization test results indicated that the sintered Ti-35Nb-2.5Sn-15HA composites exhibited higher corrosion resistance with increasing milling time. The corrosion potential and current of the Ti-35Nb-2.5Sn-15HA composite sintered by 12h milled powders were - 0.261V and 0.18μA/cm2, respectively, and this sintered composite showed a stable and wide passivation region. The hemolysis rate of the sintered Ti-35Nb-2.5Sn-15HA composites reduced with increasing milling time and the lowest hemolytic rate of the composites was 0.87%. In addition, the in vitro cell culture results indicated that the composite sintered by 12h milled powders had good biocompatibility. These results indicate the significant potential of Ti-35Nb-2.5Sn/xHA composites for biomedical implant applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti-6Al-4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
2. Electrochemical corrosion and bioactivity of titanium- hydroxyapatite composites prepared by spark plasma sintering10.1016/j.corsci.2013.01.032 ↗
3. Material processing of hydroxyapatite and titanium alloy (HA/Ti) composite as implant materials using powder metallurgy: a review10.1016/j.matdes.2013.09.045 ↗
4. Alloplastic materials for heartalve prosthesis10.1007/BF02443327 ↗
5. Effect of replacement of V by Nb and Fe on the electrochemical and corrosion behavior of Ti-6Al-4V in simulated physiological environment10.1016/j.jallcom.2004.03.096 ↗
6. An innovative fabrication of nano-HA coatings on Ti-CaP nanocomposite layer using a combination of friction stir processing and electrophoretic deposition10.1016/j.ceramint.2012.07.092 ↗
7. Study on the mechanism of hemocompatibility of Ti oxide films
8. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
9. Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion10.1089/107632700300003297 ↗
10. Mechanical compatibility of titanium implants in hard tissues10.1016/j.ics.2005.06.084 ↗
11. Effect of swaging on young's modulus of β Ti-33.6Nb-4Sn alloy10.1016/j.jmbbm.2013.10.027 ↗
12. Effect of Zr and Sn on Young's modulus and superelasticity of Ti-Nb-based alloys10.1016/j.msea.2006.09.051 ↗
13. Fabrication of nano-grained Ti-Nb-Zr biomaterials using spark plasma sintering10.1016/j.matdes.2015.08.082 ↗
14. Hydroxyapatite- silicon film deposited on Ti-Nb-10Zr by electrochemical and magnetron sputtering method10.1016/j.tsf.2016.07.086 ↗
15. The manufacturing of titanium- hydroxyapatite nanocomposites for bone implant applications10.1556/NANO.1.2006.2.7 ↗
16. Thermal stability of an ultrafine grain β-Ti alloy10.1016/j.msea.2012.07.030 ↗
17. Design and mechanical properties of new β type titanium alloys for implant materials10.1016/S0921-5093(97)00808-3 ↗
18. Microstructures and mechanical properties of metastable β TiNbSn alloys cold rolled and heat treated10.1016/j.jallcom.2006.08.267 ↗
19. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young’s modulus10.1016/j.actbio.2011.02.008 ↗
20. Effects of Sn addition on the microstructure, mechanical properties and corrosion behavior of Ti-Nb-Sn alloys10.1016/j.matchar.2014.08.014 ↗
21. Fabrication and properties of titanium-hydroxyapatite nanocomposites10.1016/j.matchemphys.2010.03.076 ↗
22. Metallic biomaterials10.1007/s10047-008-0422-7 ↗
23. Correlations between the in vitro and in vivo bioactivity of the Ti/HA composites fabricated by a powder metallurgy method10.1016/j.actbio.2008.04.015 ↗
24. The effects on bone cells of metal ions released from orthopaedic implants. A review
25. Implant surface roughness affects osteoblast gene expression10.1177/154405910308200509 ↗
26. Porous TiNbZr alloy scaffolds for biomedical applications10.1016/j.actbio.2009.06.002 ↗
27. Effects of Sn content on the microstructure, mechanical properties and biocompatibility of Ti-Nb-Sn/hydroxyapatite biocomposites synthesized by powder metallurgy10.1016/j.matdes.2013.01.012 ↗
28. Study of low-modulus biomedical β Ti-Nb-Zr alloys based on single-crystal elastic constants modeling10.1016/j.jmbbm.2016.04.040 ↗
29. Ti–Nb–Sn–hydroxyapatite composites synthesized by mechanical alloying and high frequency induction heated sintering10.1016/j.jmbbm.2011.07.006 ↗
30. The influence of plasma spraying parameters on the characteristics of hydroxyapatite coatings: a quantitative study