Manufacturing of monolithic superelastic rods with variable properties for spinal correction: Feasibility study

Yann Facchinello, Vladimir Brailovski, Karina Inaekyan, Yvan Petit, Jean-Marc Mac-Thiong

Publisher page

Abstract

A new concept of monolithic spinal rod with variable flexural stiffness is proposed to reduce the risk of adjacent segment degeneration and fracture associated with rigid spinal fixation techniques while providing adequate stability to the spine. The concept is based on the use of Ti-Ni shape memory alloy rods subjected to different processing schedules implying local annealing, cold work, or a combination of both. A feasibility study of the concurrent technological routes is performed by comparing their potential to locally control material microstructure and properties.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Shape Memory Alloy Transformations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Bellouard, Y., Lehnert, T., Bidaux, J.E., Sidler, T., Clavel, R., Gotthardt, R., 1999. Local annealing of complex mechanical devices: a new approach for developing monolithic micro-devices, ICOMAT 98. In: International Conference on Martensitic Transformations, 7–11 Dec. 1998. Elsevier, Switzerland, pp. 795–798.10.1016/S0921-5093(99)00418-9 ↗
2. Posterior pedicle fixation-based dynamic stabilization devices for the treatment of degenerative diseases of the lumbar spine10.1097/BSD.0b013e31817c6489 ↗
3. Foundations of heat and thermomechanical treatments and their effect on the structure and properties of titanium nickelide-based alloys
4. Brailovski V., Petit, Y., Mac-Thiong J-M., Driscoll M., Parent S., Labelle H., Apparatus and Method for Per-operative Modification of Medical Device Stiffness, U.S. Appl. US61/703388, Sept 15, 2012.
5. Capozzoli, J., Variable Tension Spine Articulating Rod. U.S. Appl. 2010/0160967, Jun 24, 2010.
6. Effect of strain rate on properties of superelastic NiTi thin wires10.1016/j.msea.2007.09.006 ↗
7. Functional properties of nanostructured Ti–50.0at% Ni alloys10.1520/JAI100383 ↗
8. Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65: surgical considerations and treatment options in patients with poor bone quality10.1097/01.brs.0000236893.65878.39 ↗
9. Low-cycle fatigue life of superelastic NiTi wires10.1016/j.ijfatigue.2008.03.014 ↗
10. Gayet, L.E., Rideau, Y., Vertebral Instrumentation Rod. U.S. Patent 5593,408, Jan 14, 1997.
11. Groh, J.R., Local Heat Treatment for Improved Fatigue Resistance in Turbine Components. U.S. Patent 7553,384, Jan 30, 2009.
12. Characteristics of shape memory alloys
13. Jeon, D.M., Moore, P.D., Yang, H.J., Lee, S.K., Systems and Methods for Wrought Nickel/Titanium Alloy Flexible Spinal Rods. U.S. Appl. 2009/0194206, Feb 2, 2009.
14. Justis, J.R., Sherman, M.C., Superelastic Spinal Stabilization System and Method, U.S. Patent 6,293,949, Sep 25, 2001.
15. Justis, J.R., Sherman, M.C., Superelastic Spinal Stabilization System and Method. U.S. Patent 2004/0215192, May 19, 2004a.
16. Justis, J.R., Sherman, M.C., Superelastic Spinal Stabilization System and Method and the Methods of their Manufacturing. U.S. Patent 6,761,719, Jul 13, 2004b.
17. Dynamic C spinal fusion: an evidence-based review10.1016/j.ocl.2009.12.004 ↗
18. Bending fatigue study of nickel–titanium gates glidden drills10.1097/01.don.0000148869.36136.a9 ↗
19. Gradient anneal of functionally graded NiTi10.1088/0964-1726/17/01/015031 ↗
20. Thermal and stress cycling effects and fatigue properties of Ni–Ti alloys
21. Complications in spine surgery
22. Otsuka · 1999
23. Park, K.-W., Bio-flexible Spinal Fixation Apparatus with Shape Memory Alloy. U.S. Patent 7727,259, Jun 1, 2010.
24. Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature10.1097/01.brs.0000137069.88904.03 ↗
25. Patterson, C.M., Veldman, M.S., Allard, R., Variable Stiffness Support Members. U.S. Appl. 20100160967, Dec 22, 2009.
26. Petit, D., Droulout, T., Dynamic Linking Element for a Spinal Attachment System, and Spinal Attachment System Including Said Linking Element. U.S. Patent 2007/0129729, Mar 2, 2005.
27. Functionally graded NiTi strips prepared by laser surface anneal10.1016/j.actamat.2011.11.052 ↗
28. Effects of heat treatment on mechanical behavior of Ti–Ni alloys
29. Effects of thermo-mechanical treatment on the shape memory effect and the pseudoelasticity of Ti–50.2Ni and Ti–47.5Ni–2.5Fe alloys10.2355/tetsutohagane1955.72.6_571 ↗
30. Effect of heat treatment after cold working on the phase transformation in TiNi alloy
31. Trieu, H.H., Vertebral Rod System and Methods of Use. U.S. Appl. 2010/0222820, Sep 2, 2010.
32. Structural fatigue of pseudoelastic NiTi shape memory wires10.1016/j.msea.2003.11.058 ↗
33. Zylber, E., Egli, T., Thompson, R., Froehlich, M., Cicerchia, G., Dant, J.A., Viker, T.O., Ley, K.R., 2011. Spinal Stabilization System with Rigid and Flexible Elements. U.S. Appl. 20080234744, Sep 25, 2008.