journal article·2019-03Open access

Design and material evaluation for a novel lumbar disc replacement implanted via unilateral transforaminal approach

Alba Gonzalez Alvarez, Karl D. Dearn, Duncan E.T. Shepherd

Abstract

The degeneration of the intervertebral disc is one of the principal causes of low back pain. Total disc replacement is a surgical treatment that aims to replace the degenerated disc with a dynamic implant to restore spine biomechanics. This paper proposes the first design of an elastomeric lumbar disc replacement that is implanted as a pair of devices via unilateral transforaminal surgical approach. Furthermore, several biomaterials (Polyurethanes (PU) and Polycarbonate Urethanes (PCU)) are evaluated for the purpose of the implant to mimic the axial compliance of the spine. Bionate II 80A (a pure PCU), Elast Eon 82A E5-325 (a PU with polydimethylsiloxane and polyhexamethylene oxide), Chronosil (a PCU based silicone elastomer) 80A with 5% and 10% of silicone were obtained and injection moulded according to the shape of the implant core, which was defined after a stress distribution analysis with the finite element method. The dimensions for each specimen were: 14.6 × 5.6 × 6.1 mm (length, width and height). Quasistatic compression tests were performed at a displacement rate of 0.02 mm/s. The obtained stiffness for each material at 1 mm displacement was: Bionate II 80A, 448.48 N/mm; Elast Eon 82A E5-325, 216.55 N/mm; Chronosil 80A 5%, 127.73 N/mm; and Chronosil 80A 10%, 126.48 N/mm. Dimensional changes were quantified after two quasi-static compression tests. Plastic deformation was perceived in all cases with a total percentage of height loss of: 4.1 ± 0.5% for Elast Eon 82A E5-325; 3.2 ± 0.5% for Chronosil 80A 10%; 2.7 ± 0.3% for Chronosil 80A 5% and 1.1 ± 0.2% for Bionate II 80A. The mechanical behaviour of these biomaterials is discussed to assess their suitability for the novel disc replacement device proposed.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Musculoskeletal pain and rehabilitation · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Lumbar disc arthroplasty for degenerative disc disease: a literature review10.1016/j.wneu.2017.09.153 ↗
2. ASTM International F2346-05 · 2011
3. Low back pain: current surgical approaches10.4184/asj.2015.9.4.645 ↗
4. Loading simulation of lumbar spine vertebrae during a compression test using the finite elements method and trabecular bone strength properties, determined by means of nanoindentations
5. British Standards Institution, 2011. BS ISO 18192-1:2011 Implants for Surgery. Wear of total intervertebral spinal disc prostheses. Part 1: Loading and displacement parameters for wear testing and corresponding environmental conditions for test.
6. Clinical outcomes of two types of cages used in transforaminal lumbar interbody fusion for the treatment of degenerative lumbar diseases: n-HA / PA66 cages versus PEEK cages
7. Antimicrobial polyurethanes for intravascular medical devices
8. Structural behavior of human lumbar spinal motion segments10.1016/j.jbiomech.2003.10.003 ↗
9. Gere · 1999
10. Nondegradable synthetic polymers for medical devices and implants
11. Comparative study between cobalt chrome and titanium alloy rods for multilevel spinal fusion: proximal junctional kyphosis more frequently occurred in patients having cobalt chrome rods10.1016/j.wneu.2017.04.031 ↗
12. Biomechanics of intervertebral disk degeneration10.1016/j.ocl.2011.07.001 ↗
13. The use of polyurethane materials in the surgery of the spine: a review10.1016/j.spinee.2014.08.012 ↗
14. The influence of strain rate on the compressive stiffness properties of human lumbar intervertebral discs
15. Intraoperative impaction of total knee replacements: an explicit finite-element-analysis of principal stresses in ceramic vs. cobalt–chromium femoral components10.1016/j.clinbiomech.2010.08.002 ↗
16. Viscoelastic properties of a spinal posterior dynamic stabilisation device10.1016/j.jmbbm.2016.03.011 ↗
17. The LP-ESP® lumbar disc prosthesis with 6 degrees of freedom: development and 7 years of clinical experience10.1007/s00590-012-1166-x ↗
18. A short report comparing outcomes between L4/L5 and L5/S1 single-level discectomy surgery
19. Structure–property relationships in biomedical thermoplastic polyurethane nanocomposites10.1021/ma202189e ↗
20. Total disc replacement in lumbar degenerative disc diseases10.3340/jkns.2015.58.5.401 ↗
21. Artificial total disc replacement versus fusion for lumbar degenerative disc disease: a meta-analysis of randomized controlled trials10.1007/s00402-013-1905-4 ↗
22. Lumbar disc replacement surgery—successes and obstacles to widespread adoption10.1007/s12178-017-9397-4 ↗
23. Biomechanics of nested transforaminal lumbar interbody cages10.1227/NEU.0000000000001005 ↗
24. 7.14 wear: total intervertebral disc prostheses
25. Experimental investigations into the physical properties of the intervertebral disc10.1302/0301-620X.33B4.607 ↗
26. Total disc replacement
27. Polyurethanes and silicone polyurethane copolymers
28. White · 1990 · 108
29. Titanium and cobalt–chromium alloys for hips and knees
30. A comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion: a literature review and meta-analysis10.1186/1471-2474-15-367 ↗