journal article·2021-12Open access

Experimental evaluation of the injection force exerted in intraocular lens delivery with syringe-type injectors

I. Cabeza-Gil, I. Ríos-Ruiz, B. Calvo

Abstract

The process of intraocular lens (IOL) delivery within the capsular bag during cataract surgery is crucial, as the integrity of the IOL, the injector and the ocular structures should be preserved at all times. This study aims to obtain the main parameters that affect the injection force exerted in the ejection of an intraocular lens (IOL) through syringe-type injectors. For that purpose, ejection tests were carried out in vitro, measuring the resistance force throughout the entire delivery process. The effect of IOL material, haptic design, IOL thickest area and ophthalmic viscosurgical device (OVD) was studied by ejecting seven IOLs with four syringe-type injectors of different sizes, 3.0, 2.2 and 1.8 mm. In all injectors, plate hydrophilic IOLs present the lowest resistance forces; hydrated C-loop hydrophobic IOLs present higher forces and the C-loop hydrophobic IOL in dry conditions presents the highest resistance forces. All IOLs could be properly delivered with an injector size of 2.2 mm, making injector sizes of 3.0 mm outdated. The injector size of 1.8 mm damaged several IOLs. IOL material and cartridge nozzle size were the most influential parameters in IOL delivery. IOL thickest area was also relevant but in a lesser extent whereas IOL haptic design was not as relevant.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Intraocular Surgery and Lenses · Ocular Infections and Treatments · Ocular Surface and Contact Lens

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Final incision size after implantation of a hydrophobic acrylic aspheric intraocular lens: New motorized injector versus standard manual injector10.1016/j.jcrs.2011.08.038 ↗
2. Refractive surgery beyond 2020
3. Variations in intraocular lens injector dimensions and corneal incision architecture after cataract surgery10.1016/j.jcrs.2018.10.047 ↗
4. Effect of incision size and site on corneal endothelial changes in cataract surgery10.1016/S0886-3350(01)00983-X ↗
5. Ophthalmic viscosurgical devices10.1097/ICU.0b013e3282f14db0 ↗
6. Biomechanical and optical properties of 2 new hydrophobic platforms for intraocular lenses10.1016/j.jcrs.2013.01.050 ↗
7. Systematic study on the biomechanical stability of c-loop intraocular lenses: Approach to an optimal design of the haptics.10.1007/s10439-019-02432-9 ↗
8. Effect of haptic geometry in C-loop intraocular lenses on optical quality
9. Microincisions in cataract surgery10.1016/j.jcrs.2014.07.006 ↗
10. Corneal incision quality: Microincision cataract surgery versus microcoaxial phacoemulsification10.1016/j.jcrs.2008.11.047 ↗
11. Incision size changes after cataract surgery with intraocular lens implantation10.1097/j.jcrs.0000000000000014 ↗
12. Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study10.1038/eye.2014.162 ↗
13. Linear deposits on the surfaces of intraocular lenses implanted through a hexagonal cartridge which mimic scratches/cracks on the lenses10.1136/bjo.2005.071738 ↗
14. Intraocular lens injector–induced stress on the corneal incisions during lens implantation10.1016/j.ajo.2014.03.001 ↗
15. Influence of intraocular lens material on the development of acute endophthalmitis after cataract surgery?10.1038/sj.eye.6702544 ↗
16. Incision sizes before and after implantation of SN60wf intraocular lenses using the monarch injector system with c and d cartridges10.1016/j.jcrs.2008.06.031 ↗
17. The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge10.1136/bjo.2006.097857 ↗
18. Bacterial endophthalmitis after small-incision cataract surgery10.1016/S0886-3350(02)01483-9 ↗
19. Evaluation of preloaded intraocular lens injection systems: Ex vivo study10.1016/j.jcrs.2017.02.019 ↗
20. In vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions10.1016/j.jcrs.2018.10.050 ↗
21. Effect of intraocular lens insertion speed on surgical wound structure10.1016/j.jcrs.2012.06.031 ↗
22. Robot-assisted intraocular surgery: development of the IRISS and feasibility studies in an animal model10.1038/eye.2013.105 ↗
23. Biomechanical stability of three intraocular lenses with different haptic designs: In silico and in vivo evaluation.10.3928/1081597X-20200713-02 ↗
24. Intra-ocular acrylic lenses : A recent development in the surgery of cataract10.1136/bjo.36.3.113 ↗
25. Modified injector for optimal insertion of standard ctrs in lax zonules10.5301/ejo.5000613 ↗
26. Resistance force for intraocular lens insertion through lens cartridges and syringe-type injectors10.1016/j.jcrs.2015.03.018 ↗
27. In vitro delivery performance assessment of a new preloaded intraocular lens delivery system10.1016/j.jcrs.2016.10.014 ↗
28. Remnant extraction by using an intraocular lens injector with essential flow10.5301/ejo.5000962 ↗