journal article·2022-05

Multiscale mechanical model based on patient-specific geometry: Application to early keratoconus development

C. Giraudet, J. Diaz, P. Le Tallec, J.-M. Allain

Publisher page

Abstract

Keratoconus is a pathology of the cornea associated with a tissue thinning and a weakening of its mechanical properties. However, it remains elusive which aspect is the leading cause of the disease. To investigate this question, we combined a multiscale model with a patient-geometry in order to simulate the mechanical response of healthy and pathological corneas under intraocular pressure. The constitutive behavior of the cornea is described through an energy function which takes into account the isotropic matrix of the cornea, the geometric structure of collagen lamellae and the quasi-incompressibility of the tissue. A micro-sphere description is implemented to take into account the typical features of the collagen lamellae as obtained experimentally, namely their orientation, their stiffness and their dispersion, as well as the their unfolding stretch, at which they start to provide a significant force. A set of reference parameters is obtained to fit experimental inflation data of the literature. We show that the most sensitive parameter is the unfolding stretch, as a small variation of this parameter induces a major change in the corneal apex displacement. The keratoconus case is then studied by separating the impact of the geometry and the one of the mechanics. We computed the evolution of the SimK (a clinical indicator of cornea curvature) and elevation maps: we were able to reproduce the reported changes of SimK with pressure only by a mechanical weakening, and not by a change in geometry. More specifically, the weakening has to target the lamellae and not the matrix. The mechanical weakening leads to elevations close to early stage keratoconus, but our model lacks the remodeling component to couple the change in mechanics with changes in geometry. Still, these findings indicate that new methods for early diagnosis of keratoconus should focus on the detection of a mechanical weakening, and that stiffening treatments should be appropriate.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corneal surgery and disorders · Corneal Surgery and Treatments · Glaucoma and retinal disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (75)

Show source-provided references
1. X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus10.1016/j.str.2004.01.002 ↗
2. Ultrastructural analysis of collagen fibrils and proteoglycans in keratoconus10.1111/j.1755-3768.2007.01142.x ↗
3. The effect of keratoconus on the structural, mechanical, and optical properties of the cornea10.1016/j.jmbbm.2010.09.014 ↗
4. Characterization of non-linear mechanical behavior of the cornea10.1038/s41598-020-68391-7 ↗
5. Quantitative discrimination of healthy and diseased corneas with second harmonic generation microscopy10.1167/tvst.8.3.51 ↗
6. Contact lenses in the management of keratoconus10.1097/ICO.0b013e318211401f ↗
7. Scheimpflug imaging for keratoconus and ectatic disease10.4103/0301-4738.116059 ↗
8. The hierarchical response of human corneal collagen to load10.1016/j.actbio.2017.11.015 ↗
9. Simultaneous microstructural and mechanical characterization of human corneas at increasing pressure10.1016/j.jmbbm.2015.12.031 ↗
10. Assessment of the number of lamellae in the central region of the normal human corneal stroma at the resolution of the transmission electron microscope10.1097/01.ICL.0000165280.94927.0D ↗
11. Full-field deformation of bovine cornea under constrained inflation conditions10.1016/j.biomaterials.2008.06.011 ↗
12. A new approach to Keratoconus detection based on corneal morphogeometric analysis10.1371/journal.pone.0184569 ↗
13. Study of morpho-geometric variables to improve the diagnosis in keratoconus with mild visual limitation10.3390/sym10080306 ↗
14. Local mechanical and structural properties of healthy and diseased human ascending aorta tissue10.1016/j.carpath.2008.01.001 ↗
15. Anterior and posterior corneal stroma elasticity assessed using nanoindentation10.1016/j.exer.2013.06.004 ↗
16. Contact lens management of keratoconus10.1111/cxo.12300 ↗
17. Assessing progression of keratoconus: novel tomographic determinants10.1186/s40662-016-0038-6 ↗
18. Determination of corneal biomechanical behavior in-vivo for healthy eyes using CorVis ST tonometry: Stress-strain index10.3389/fbioe.2019.00105 ↗
19. Biomechanical properties of human and porcine corneas10.1016/j.exer.2008.02.006 ↗
20. Comparative study of corneal strip extensometry and inflation tests10.1098/rsif.2005.0034 ↗
21. Modelling approaches for evaluating multiscale tendon mechanics10.1098/rsfs.2015.0044 ↗
22. A comparative study of the elastic fibre system within the mouse and human cornea10.1016/j.exer.2018.07.024 ↗
23. 2008
24. Corneal elevation topography: Best fit sphere, elevation distance, asphericity, toricity, and clinical implications10.1097/ICO.0b013e3181fb4fa7 ↗
25. Biomechanical analysis of the keratoconic cornea10.1016/j.jmbbm.2008.07.002 ↗
26. Gilles, Sébastien, Gitlab MoReFEM. https://gitlab.inria.fr/MoReFEM/CoreLibrary/MoReFEM.
27. Monitoring micrometer-scale collagen organization in rat-tail tendon upon mechanical strain using second harmonic microscopy10.1016/j.jbiomech.2011.05.009 ↗
28. Corneal biomechanical properties after SMILE versus FLEX, LASIK, LASEK, or PRK: A systematic review and meta-analysis10.1186/s12886-019-1165-3 ↗
29. Optical coherence elastography assessment of corneal viscoelasticity with a modified Rayleigh-Lamb wave model10.1016/j.jmbbm.2016.11.004 ↗
30. Distribution of intraocular pressure in healthy Iranian individuals: the tehran eye study10.1136/bjo.2004.058057 ↗
31. Femtosecond laser-assisted corneal flap cuts: Morphology, accuracy, and histopathology10.1167/iovs.05-1123 ↗
32. Parametric fitting of corneal height data to a biconic surface10.1016/j.zemedi.2014.02.005 ↗
33. The emergence of optical elastography in biomedicine10.1038/nphoton.2017.6 ↗
34. Biomechanics of LASIK flap and SMILE cap: A prospective, clinical study10.3928/1081597X-20190319-01 ↗
35. Corneal viscoelastic properties from finite-element analysis of in vivo air-puff deformation10.1371/journal.pone.0104904 ↗
36. In vivo structural imaging of the cornea by polarization-resolved second harmonic microscopy10.1364/BOE.3.000001 ↗
37. MR elastography of the ex vivo bovine globe10.1002/jmri.22217 ↗
38. Analysis of the viscoelastic properties of the human cornea using scheimpflug imaging in inflation experiment of eye globes10.1371/journal.pone.0112169 ↗
39. A novel microstructural interpretation for the biomechanics of mouse skin derived from multiscale characterization10.1016/j.actbio.2016.12.051 ↗
40. The structure and transparency of the cornea10.1113/jphysiol.1957.sp005758 ↗
41. Corneal responses to intraocular pressure elevations in keratoconus10.1097/ICO.0b013e3181ca2b75 ↗
42. The use of X-ray scattering techniques to quantify the orientation and distribution of collagen in the corneal stroma10.1016/j.preteyeres.2009.06.005 ↗
43. Corneal structure and transparency10.1016/j.preteyeres.2015.07.001 ↗
44. Changes in collagen orientation and distribution in Keratoconus corneas10.1167/iovs.04-1253 ↗
45. Three-dimensional mapping of the orientation of collagen corneal lamellae in healthy and keratoconic human corneas using SHG microscopy10.1002/jbio.201600122 ↗
46. Long-term corneal morphology after PRK by in vivo confocal microscopy10.1167/iovs.02-0247 ↗
47. Montanino, Andrea, Gizzi, Alessio, Vasta, Marcello, Angelillo, Maurizio, Pandolfi, Anna, Modeling the biomechanics of the human cornea accounting for local variations of the collagen fibril architecture. ZAMM - J. Appl. Math. Mech. / Z. Angew. Math. Mech..
48. Histopathologic findings of keratoconus corneas underwent penetrating keratoplasty according to topographic measurements and keratoconus severity
49. The correlation between keratoconus and eye rubbing: a review10.18240/ijo.2019.11.17 ↗
50. Circumcorneal annulus of collagen fibrils in the human limbus
51. An inverse finite element method for determining the anisotropic properties of the cornea10.1007/s10237-010-0237-3 ↗
52. A model for the human cornea: constitutive formulation and numerical analysis10.1007/s10237-005-0014-x ↗
53. Fiber distributed hyperelastic modeling of biological tissues10.1016/j.mechmat.2011.06.004 ↗
54. The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens10.1088/1361-6560/aa54ef ↗
55. Corneal biomechanical properties after LASIK, ReLEx Flex, and Relex smile by Scheimpflug-based dynamic tonometry10.1007/s00417-014-2667-6 ↗
56. The role of 3-D collagen organization in stromal elasticity: a model based on X-ray diffraction data and second harmonic-generated images10.1007/s10237-012-0466-8 ↗
57. Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus10.1016/j.jcrs.2009.11.012 ↗
58. Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE10.1038/s41598-020-69909-9 ↗
59. Interlacing of collagen Lamellae in the midstroma of the human cornea10.1097/00003226-200208000-00013 ↗
60. Altered organization of collagen in the apex of Keratoconus corneas10.1159/000055492 ↗
61. Biomechanics of corneal ectasia and biomechanical treatments10.1016/j.jcrs.2014.04.013 ↗
62. Corneal biomechanics and biomaterials10.1146/annurev-bioeng-070909-105243 ↗
63. Biomechanical characterization of keratoconus corneas ex vivo with brillouin microscopy10.1167/iovs.14-14450 ↗
64. Comparative evaluation of tomographic and biometric characteristics in bilateral keratoconus patients with unilateral corneal vogt & rsquo;s striae: a contralateral eye study10.2147/OPTH.S169266 ↗
65. Brillouin spectroscopy of normal and Keratoconus corneas10.1016/j.ajo.2019.02.010 ↗
66. Customized finite element modelling of the human cornea10.1371/journal.pone.0130426 ↗
67. Biomechanical model of human cornea based on stromal microstructure10.1016/j.jbiomech.2009.11.021 ↗
68. Supersonic shear wave elastography for the in vivo evaluation of transepithelial corneal collagen cross-linking10.1167/iovs.13-13445 ↗
69. Corneal stromal changes induced by myopic LASIK
70. Constitutive modeling of corneal tissue: influence of three-dimensional collagen fiber microstructure10.1115/1.4048401 ↗
71. Biomechanical model of the human cornea: Considering shear stiffness and regional variation of collagen anisotropy and density10.1016/j.jmbbm.2014.11.006 ↗
72. Nonlinear optical macroscopic assessment of 3-D corneal collagen organization and axial biomechanics10.1167/iovs.11-8070 ↗
73. Three-dimensional distribution of transverse collagen fibers in the anterior human corneal stroma10.1167/iovs.13-13150 ↗
74. A comparison of biomechanical properties between human and porcine cornea10.1016/S0021-9290(00)00219-0 ↗
75. Microstructure-based numerical simulation of the mechanical behaviour of ocular tissue10.1098/rsif.2018.0685 ↗