Digital Volume Correlation for large deformations of soft tissues: Pipeline and proof of concept for the application to breast ex vivo deformations
Source abstract
Abstract
Being able to reposition tumors from prone imaging to supine surgery stances is key for bypassing current invasive marking used for conservative breast surgery. This study aims to demonstrate the feasibility of using Digital Volume Correlation (DVC) to measure the deformation of a female quarter thorax between two different body positioning when subjected to gravity. A segmented multipart mesh (bones, cartilage and tissue) was constructed and a three-step FE-based DVC procedure with heterogeneous elastic regularization was implemented. With the proposed framework, the large displacement field of a hard/soft breast sample was recovered with low registration residuals and small error between the measured and manually determined deformations of phase interfaces. The present study showed the capacity of FE-based DVC to faithfully capture large deformations of hard/soft tissues.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Optical measurement and interference techniques · Ultrasound Imaging and Elastography · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Methods and applications of digital volume correlation10.1243/03093247JSA436 ↗
2. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
3. 3D analysis from micro-MRI during in situ compression on cancellous bone10.1016/j.jbiomech.2009.06.034 ↗
4. A method for registration of 3-D shapes10.1109/34.121791 ↗
5. Digital volume correlation: Review of progress and challenges10.1007/s11340-018-0390-7 ↗
6. Evaluation of measurement uncertainties of digital volume correlation applied to laminography data10.1177/0309324717748097 ↗
7. A finite element formulation to identify damage fields: The equilibrium gap method10.1002/nme.1057 ↗
8. A practical guide for in situ mechanical testing of musculoskeletal tissues using synchrotron tomography10.1016/j.jmbbm.2022.105297 ↗
9. Breast cancer statistics, 2019
10. Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns10.1016/j.actbio.2019.05.021 ↗
11. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain ex vivo10.1111/jmi.12701 ↗
12. Regional variations in discrete collagen fibre mechanics within intact intervertebral disc resolved using synchrotron computed tomography and digital volume correlation10.1016/j.actbio.2021.10.012 ↗
13. Surgery of nonpalpable breast cancer: First step to a virtual per-operative localization? First step to virtual breast cancer localization10.1111/tbj.13379 ↗
14. Surface driven biomechanical breast image registration
15. 3D slicer as an image computing platform for the quantitative imaging network10.1016/j.mri.2012.05.001 ↗
16. Modeling costal cartilage using local material properties with consideration for gross heterogeneities10.1016/j.jbiomech.2010.11.034 ↗
17. Predicting tumor location by modeling the deformation of the breast10.1109/TBME.2008.925714 ↗
18. Simulation and visualization to support breast surgery planning
19. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
20. Comparison of the compressive mechanical properties of auricular and costal cartilage from patients with microtia10.1016/j.jbiomech.2020.109688 ↗
21. Toward 4D mechanical correlation
22. Damage measurements via DIC10.1007/s10704-015-0004-7 ↗
23. Digital image correlation
24. Ultrasonic determination of the elastic modulus of human cortical bone10.1007/BF02522857 ↗
25. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
26. Characterization of costal cartilage and its suitability as a cell source for articular cartilage tissue engineering10.1002/term.2630 ↗
27. In-vivo quantification of human breast deformation associated with the position change from supine to upright10.1016/j.medengphy.2014.09.016 ↗
28. Digital volume correlation: What are the limits to the spatial resolution?10.1051/meca/2012025 ↗
29. Voxel-scale digital volume correlation10.1007/s11340-010-9407-6 ↗
30. Breast image registration by combining finite elements and free-form deformations
31. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
32. A rigged model of the breast for preoperative surgical planning10.1016/j.jbiomech.2021.110645 ↗
33. Complete mechanical regularization applied to digital image and volume correlation10.1016/j.cma.2019.06.005 ↗
34. Three-dimensional static optical coherence elastography based on inverse compositional Gauss-Newton digital volume correlation10.1002/jbio.201800422 ↗
35. A biomechanical breast model evaluated with respect to MRI data collected in three different positions10.1016/j.clinbiomech.2018.10.020 ↗
36. 3D static elastography at the micrometer scale using full field OCT10.1364/BOE.4.002138 ↗
37. Mechanically regularized FE DIC for heterogeneous materials10.1007/s11340-019-00529-9 ↗
38. Microfe models of porcine vertebrae with induced bone focal lesions: Validation of predicted displacements with digital volume correlation10.1016/j.jmbbm.2021.104872 ↗
39. The use of digital image correlation in the biomechanical area: a review
40. Payan · 2017
41. Nonlinear micro finite element models based on digital volume correlation measurements predict early microdamage in newly formed bone10.1016/j.jmbbm.2022.105303 ↗
42. Novel method to track soft tissue deformation by micro-computed tomography: Application to the mitral valve10.1007/s10439-015-1499-9 ↗
43. Rajagopal · 2007
44. The breast biomechanics reference state for multi-modal image analysis
45. Modeling breast biomechanics for multi-modal image analysis-successes and challenges10.1002/wsbm.58 ↗
46. Developing an analogue residual limb for comparative DVC analysis of transtibial prosthetic socket designs10.3390/ma13183955 ↗
47. Young’s modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
48. Full-field in vitro investigation of hard and soft tissue strain in the spine by means of digital image correlation10.32098/mltj.04.2017.08 ↗
49. Characterization of chemoelastic effects in arteries using digital volume correlation and optical coherence tomography10.1016/j.actbio.2019.11.049 ↗
50. Gaining insight into the deformation of achilles tendon entheses in mice10.1002/adem.202100085 ↗
51. The longitudinal Young?s modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data10.1007/s00223-002-2123-1 ↗
52. Computer vision-based, noncontacting deformation measurements in mechanics: A generational transformation
53. Sutton · 2009
54. Localized strain field measurement on laminography data with mechanical regularization10.1016/j.nimb.2013.09.033 ↗
55. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: Local analysis on bone and cement-bone microstructures10.1016/j.jmbbm.2016.12.006 ↗
56. Damage quantification via digital volume correlation with heterogeneous mechanical regularization: Application to an in situ meso-flexural test on mortar
57. A combined experimental and numerical method to estimate the elastic modulus of single trabeculae10.1016/j.jmbbm.2021.104879 ↗