journal article·2016-03

Degradation of Ti–6Al–4V alloy under cyclic loading in a simulated body environment with cell culturing

Kotaro Doi, Sayaka Miyabe, Hiroaki Tsuchiya, Shinji Fujimoto

Publisher page

Abstract

The present study reports the corrosion fatigue of the Ti-6Al-4V alloy using cyclic deformation test in a simulated body fluid under cell culturing for the first time. Cyclic deformation tests were carried out using three types of specimens to reveal the effects of proteins and cells on the corrosion fatigue of the alloy. For the 1-day-immersed and 1-week-immersed specimens, tensile specimens were soaked in a simulated body fluid for 1 day and 1 week, respectively, before cyclic deformation test, whereas for the cell-cultured specimen, MC3T3-E1 osteoblast-like cells were seeded and then cultured on tensile specimens for 1 week. The incubation period for crack initiation was longer for the cell-cultured and 1-week-immersed specimens compared to that for the 1-day-immersed specimen. On the other hand, crack propagation period for the cell-cultured and 1-week-immersed specimens was shorter than that for the 1-day-immersed specimen. These results indicate that proteins and cells adhered on the alloy surface inhibit metal dissolution at newly created surface emerged by cyclic deformation to suppress crack initiation, whereas they accelerate crack propagation because dissolution at crack tip is accelerated in the occluded space formed under proteins and cells.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Reliability-based design guidelines for fatigue of ship structures10.1111/j.1559-3584.2002.tb00127.x ↗
2. Corrosion rate measurements in vivo10.1002/jbm.820010405 ↗
3. Corrosion behaviour of CoCrMo implant alloy during fretting in bovine serum10.1016/j.corsci.2004.09.003 ↗
4. A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serum10.1016/j.electacta.2004.07.024 ↗
5. Breakdown of passive films and repassivation of Ti–6Al–4V alloy with rapid elongation in simulated body fluid including osteoblast-like cells10.1149/2.085311jes ↗
6. Fatigue property of Ti–5Al–13Ta alloy dental castings in 0.9% NaCl solution10.2320/matertrans.47.2444 ↗
7. Electrochemical behavior on Type 316L stainless steel during cyclic deformation in simulated body fluid including proteins and cells10.2320/matertrans.M2014301 ↗
8. Metal dissolution and repassivation of Ti–6Al–4V Alloy during rapid elongation in simulated body fluid including osteoblast-like cells10.1149/05016.0001ecst ↗
9. In vivo measurement of electrical parameters with alumina-covered stainless steel electrodes10.1016/0142-9612(86)90102-X ↗
10. Osseous implant for studies of biomaterials using an in vivo electrochemical transducer10.1002/jbm.820270609 ↗
11. Passivity breakdown and repassivation on TiNi during rapid straining accompanying martensitic phase transformation10.1149/1.3229971 ↗
12. Development of electrolytic cell with cell-culture for metallic biomaterials10.1016/S0010-938X(01)00110-X ↗
13. The influence of proteins on the fretting-corrosion behaviour of a Ti6Al4V alloy10.1016/j.wear.2006.03.032 ↗
14. Electrochemical properties of 316L stainless steel with culturing L929 fibroblasts10.1098/rsif.2005.0108 ↗
15. In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids10.1016/j.actbio.2015.03.008 ↗
16. The corrosion/wear mechanisms of Ti–6Al–4V alloy for different scratching rates10.1016/j.wear.2006.11.025 ↗
17. Biocompatibility studies on surgical-grade titanium-, cobalt-, and iron-base alloys10.1002/jbm.820100411 ↗
18. Cyclic deformation behaviour and fatigue induced surface damage of titanium alloys in simulated physiological media10.1016/j.msec.2005.01.020 ↗
19. In vivo measurement of anodic polarization of orthopaedic implant alloys: comparative study of in vivo and in vitro experiments10.1016/0142-9612(89)90134-8 ↗
20. Effects of scratching rate on the corrosion wear mechanism of Ti–6Al–4V alloys10.2472/jsms.54.940 ↗
21. Comparison of the in vivo and in vitro corrosion of 18–8 stainless steel and titanium10.1002/jbm.820030308 ↗
22. In vitro corrosion study by EIS of a nickel-free stainless steel for orthopaedic applications10.1016/j.biomaterials.2004.03.012 ↗
23. In vitro corrosion testing of titanium surgical implant alloys: an approach to understanding titanium release from implants10.1002/jbm.820130206 ↗
24. Micro-abrasion-corrosion of a CoCrMo alloy in simulated artificial hip joint environments10.1016/j.wear.2005.02.045 ↗
25. Fretting corrosion behaviour of Ti–6Al–4V alloy in artificial saliva containing varying concentrations of fluoride ions10.1016/j.wear.2010.09.008 ↗
26. Breakdown of passive film on Ni–Cr alloys in high-temperature high-pressure water containing sulfate ions10.5006/1.3585036 ↗
27. Conservation In vitro of threatened plants—progress in the past decade10.1079/IVP2006769 ↗
28. Effect of CaCl2 concentration on the probability distribution of stress corrosion cracking failure time of Type 304 stainless steel
29. Application of the scannning vibrating electrode technique to corrosion fatigue
30. Electrochemical study of Type 304 and 316L stainless steels in simulated body fluids and cell cultures10.1016/j.actbio.2006.06.003 ↗
31. The influence of surface defects on high-cycle fatigue of engineering materials10.1007/BF02209092 ↗