journal article·2016-03

Immediate postoperative changes in synthetic meshes – measurements

Nikhil Sindhwani, Zahra Liaquat, Iva Urbankova, Greetje Vande Velde, Andrew Feola, Jan Deprest

Publisher page

Abstract

Background and objective Immediate post-operative structural changes in implanted synthetic meshes are believed to contribute to graft related complications. Our aim was to observe in vivo dimensional changes at the pore level. Method Two different polyvinylidine fluoride (PVDF) meshes, CICAT and ENDOLAP (Dynamesh, FEG Textiltechnik) were implanted in 18 female Sprague Dawley (n=9/group). The meshes (30×25mm(2)) were overlaid on a full thickness incision (2×1cm(2)) and sutured on the abdominal wall. All animals underwent microCT imaging (res. 35µm/px) at day 1 and 15 postsurgery. A customized procedure was developed to semi-automatically detect the pore centers from the microCT dataset. Horizontal (transverse) and vertical (cranio-caudal) inter-pore distances were then recorded. The overall mesh dimensions were also noted from 3D models generated from in vivo microCT datasets. Inter-pore distances and the overall dimensions from microCT images of the meshes set in agarose gel phantom were used as controls. Mann-Whitney U test was done to check for significant differences. Results Number of measurable vertical and horizontal inter-pore distances was 56.5(10.5) and 54.5(14.5) [median (IQR)] per animal. At day 1, we observed a 4.3% (CICAT) and 4.6% (ENDOLAP) increase in vertical inter-pore distance when compared to controls (p<0.001, p=0.003, respectively). Measurements fell back to phantom values by day 15 (3.7% and 4.9% decrease compared to day 1, p<0.001 for both). The horizontal inter-pore distances for ENDOLAP increased by 1.4% (p=0.003) during the two weeks period. The overall mesh dimensions did not change significantly day 1 and day 15. The in vivo measurement of the overall mesh dimensions demonstrated a 15.9% reduction in mesh area as compared to that in phantom controls. Conclusion We report for the first time, in vivo changes in pore dimensions of a textile implant. This study clearly demonstrates the dynamic nature of a textile implant during the tissue integration process. For studied PVDF meshes, the process of tissue integration leads to limited but significant reduction over time as observed at the pore level. Remarkably the extent of this reduction does not account for the change in overall mesh dimensions.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hernia repair and management · Reconstructive Surgery and Microvascular Techniques · Aortic aneurysm repair treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Lifetime risk of undergoing surgery for pelvic organ prolapse10.1097/AOG.0b013e3181f73729 ↗
2. Risk factors for the recurrence of pelvic organ prolapse after vaginal surgery: a review at 5 years after surgery10.1007/s00192-007-0321-0 ↗
3. Review of synthetic mesh-related complications in pelvic floor reconstructive surgery10.1007/s00192-008-0717-5 ↗
4. Haylen · Neurourol. Urodyn. · 2011 · 12 · 210.1002/nau.21036 ↗
5. Vaginal mesh contraction: definition, clinical presentation and management10.1097/AOG.0b013e3181cbca4d ↗
6. Time-dependent changes of magnetic resonance imaging-visible mesh implants in patients
7. Mesh contraction: in-vivo documentation of changes in apparent surface area utilizing magnetic resonance image visible meshes in the rabbit abdominal wall model
8. Magnetic resonance–visible meshes for laparoscopic ventral hernia repair10.4293/JSLS.2014.00175 ↗
9. Ultrasound appearances after mesh implantation – evidence of mesh contraction or folding?10.1007/s00192-010-1308-9 ↗
10. Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit10.1016/j.jss.2006.09.015 ↗
11. Evaluation of new prosthetic meshes for ventral hernia repair10.1007/s00464-005-0706-4 ↗
12. Abdominal wall hernia repair: a long-term comparison of Sepramesh and Dualmesh in a rabbit hernia model10.1177/000313480407000801 ↗
13. Shrinkage of intraperitoneal onlay mesh in sheep: coated polyester mesh versus covered polypropylene mesh10.1007/s10029-010-0682-z ↗
14. Shrinkage and biomechanical evaluation of lightweight synthetics in a rabbit model for primary fascial repair10.1007/s00192-011-1440-1 ↗
15. In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides10.1007/s00464-011-2057-7 ↗
16. Mechanical biocompatibility of prosthetic meshes: a comprehensive protocol for mechanical characterization10.1016/j.jmbbm.2014.08.005 ↗
17. Structural alterations of prosthetic meshes in humans10.1007/s10029-002-0089-6 ↗
18. PVDF as a new polymer for the construction of surgical meshes10.1016/S0142-9612(02)00070-4 ↗
19. Radiation effects on bone architecture in mice and rats resulting from in vivo micro-computed tomography scanning10.1016/j.medengphy.2007.11.004 ↗
20. Fundamental image quality limits for microcomputed tomography in small animals10.1118/1.1617353 ↗
21. In vivo small animal imaging using micro-CT and digital subtraction angiography10.1088/0031-9155/53/19/R01 ↗
22. Gonzalez · 2010
23. Natan · Fast 2D peak finder · 2012
24. Follow-up after polypropylene mesh repair of anterior and posterior compartments in patients with recurrent prolapse10.1007/s00192-006-0291-7 ↗
25. Classification of biomaterials and their related complications in abdominal wall hernia surgery10.1007/BF02426382 ↗
26. Differences in polypropylene shrinkage depending on mesh position in an experimental study10.1016/j.amjsurg.2006.06.045 ↗
27. Relationship between tissue ingrowth and mesh contraction10.1007/s00268-005-7786-0 ↗
28. Mechanical biocompatibility of highly deformable biomedical materials10.1016/j.jmbbm.2015.03.023 ↗