journal article·2020-04

Posterior bone graft in lumbar spine surgery reduces the stress in the screw-rod system- A finite element study

Raghu N. Natarajan, Kei Watanabe, Kazuhiro Hasegawa

Publisher page

Abstract

Purpose Analyze the biomechanical effect of postero-lateral instrumentation with and without posterior bone graft as well as effect of consolidation of the graft. Study objectives are (1) whether bone graft alone will provide enough additional strength to the weakened spine, (2) how the addition of posterior bone graft help in extending the life of the fusion construct, and (3) compare the effect of gradual consolidation of the bone-graft on the spine biomechanics. Methods A lumbar spine finite element model was used to analyze the effects of bone-graft alone and varying grades of bone-graft consolidation with postero-lateral instrumentation on spine biomechanics. The spine stiffness and stresses in the posterior rods and screws were determined for moments applied in the three physiological directions in addition to pre-load. Results Stiffness of a normal lumbar spine with a solid consolidated posterior bone graft was found to be 10 times that of an intact lumbar spine. Posterior instrumentation further increased the spine stiffness by 20 fold. A 50% solid consolidation of the graft reduced the screw-rod maximum von-Mises stress by 45% and a 65% reduction in screw-rod stress was calculated with completely fused graft. Conclusion A fused graft with posterior instrumentation provided a 200 fold increase in stiffness of an intact spine while producing stress shielding to the Ti rod-screw system. Considerable reduction of the maximum von-Mises stresses in the postero-lateral rod and screw fusion system (65%) will contribute to prevention of implant failure under repetitive loading highlighting the importance of consolidation of posterior bone-graft.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study10.1016/j.spinee.2014.06.015 ↗
2. Mechanical testing of spinal instrumentation10.1097/00003086-198802000-00015 ↗
3. Instability and instrumentation failures after a PSO: a finite element analysis10.1007/s00586-014-3295-x ↗
4. Monolithic superelastic rods with variable flexural stiffness for spinal fusion: simplified finite element analysis of an instrumented spine segment
5. Biomechanical assessment of the stabilization capacity of monolithic spinal rods with different flexural stiffness and anchoring arrangement10.1016/j.clinbiomech.2015.09.011 ↗
6. Finite element analysis of 3 posterior fixation techniques in the lumbar spine10.3928/01477447-20140430-54 ↗
7. Rod stiffness as a risk factor of proximal junctional kyphosis after adult spinal deformity surgery: comparative study between cobalt chrome multiple-rod constructs and titanium alloy two-rod construct10.1016/j.spinee.2017.02.005 ↗
8. Segmental in vivo vertebral motion during functional human lumbar spine activities10.1007/s00586-009-0936-6 ↗
9. Biomechanical analysis of the proximal adjacent segment after multilevel instrumentation of the thoracic spine: do hooks ease the transition?10.1055/s-0035-1563611 ↗
10. Mechanical strength of bone allografts subjected to chemical sterilization and other terminal processing methods
11. Biomechanical analysis of a long-segment fusion in a lumbar spine-A finite element model study10.1115/1.4039989 ↗
12. Fatigue characteristics of metallic biomaterials10.1016/j.ijfatigue.2006.09.021 ↗
13. Biomechanical evaluation of spinal fixation devices: I. A conceptual framework10.1097/00007632-198810000-00013 ↗
14. Segmental lumbar rotation in patients with discogenic low back pain during functional weight-bearing activities10.2106/JBJS.I.01348 ↗
15. Novel model to analyze the effect of a large compressive follower pre-load on range of motions in a lumbar spine10.1016/j.jbiomech.2006.05.019 ↗
16. Loads on an internal spinal fixation device during walking10.1016/S0021-9290(96)00103-0 ↗
17. Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis10.1007/s00586-006-0292-8 ↗
18. Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments -- A finite element study10.1016/j.jbiomech.2008.11.024 ↗
19. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement10.1097/00007632-198809000-00008 ↗