Polycarbonate-urethane coating can significantly improve talus implant contact characteristics
Source abstract
Abstract
Talus implants can be utilized in cases of talus avascular necrosis and has been regarded as a promising treatment method. However, existing implants are made of stiff materials that directly oppose natural cartilage. The risk of long-term cartilage wear and bone fracture from the interaction between the cartilage and stiff implant surfaces has been documented in post-hemiarthroplasty of the hip, knee and ankle joints. The aim is to explore the effects of adding a layer of compliant material (polycarbonate-urethane; PCU) over a stiff material (cobalt chromium) in talus implants. To do so, we obtained initial ankle geometry from four cadaveric subjects in neutral standing to create the finite element models. We simulated seven models for each subject: three different types of talus implants, each coated with and without PCU, and a biological model. In total, we constructed 28 finite element models. By comparing the contact characteristics of the implant models with their respective biological model counterparts, our results showed that PCU coated implants have comparable contact area and contact pressure to the biological models, whereas stiff material implants without the PCU coating all have relatively higher contact pressure and smaller contact areas. These results confirmed that adding a layer of compliant material coating reduces the contact pressure and increases the contact area which in turn reduces the risk of cartilage wear and bone fracture. The results also suggest that there can be clinical benefits of adding a layer of compliant material coating on existing stiff material implants, and can provide valuable information towards the design of more biofidelic implants in the future.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Foot and Ankle Surgery · Lower Extremity Biomechanics and Pathologies · Tendon Structure and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Clinical Results of the NUsurface® Meniscus Implant versus Non-Surgical Controls at 24 months: Data from a Pooled cohort of a randomized controlled study and single arm study10.1177/2325967120S00367 ↗
2. Physical validation of a patient-specific contact finite element model of the ankle10.1016/j.jbiomech.2007.01.024 ↗
3. Intra-articular contact stress distributions at the ankle throughout stance phase-patient-specific finite element analysis as a metric of degeneration propensity10.1007/s10237-006-0025-2 ↗
4. Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature10.4047/jap.2014.6.2.138 ↗
5. Total talar replacement for idiopathic necrosis of the talus: a case report10.1053/j.jfas.2015.07.015 ↗
6. Anatomic total talar prosthesis replacement surgery and ankle arthroplasty: an early case series in Thailand
7. Morphometric geometric differences between right and left human tali: a cadaveric study of fluctuating asymmetry via systematic measurement and three-dimensional scanning10.1371/journal.pone.0232012 ↗
8. Development and implantation of a universal talar prosthesis10.3389/fsurg.2019.00063 ↗
9. Assessment of common hyperelastic constitutive equations for describing normal and osteoarthritic articular cartilage10.1243/09544119JEIM546 ↗
10. The mechanical response of a polyetheretherketone femoral knee implant under a deep squatting loading condition10.1177/0954411917738805 ↗
11. Decreased stress shielding with a PEEK femoral total knee prosthesis measured in validated computational models10.1016/j.jbiomech.2021.110270 ↗
12. An eleven-year follow-up of a custom talar prosthesis after open talar extrusion in an adolescent patient: a case report10.2106/JBJS.CC.L.00331 ↗
13. Guyen · 2019 · vol. 105
14. The talar body prosthesis: results at ten to thirty-six years of follow-up10.2106/JBJS.M.00377 ↗
15. Unipolar hemiarthroplasty versus bipolar hemiarthroplasty in the most elderly patients with displaced femoral neck fractures: a randomised, controlled trial10.1007/s00264-011-1213-y ↗
16. Symmetry analysis of talus bone10.1302/2046-3758.35.2000264 ↗
17. Changes in bone mineral density of the distal femur after total knee arthroplasty: a 7-year DEXA follow-up comparing results between obese and nonobese patients10.1016/j.knee.2013.03.004 ↗
18. Unipolar versus bipolar hemiarthroplasty for displaced femoral neck fractures: a systematic review and meta-analysis of randomized controlled trials10.1186/s13018-015-0165-0 ↗
19. Ceramic artificial talus as the initial treatment for comminuted talar fractures [formula: see text]
20. Bone mineral density of the femur in autopsy retrieved total knee arthroplasties10.1016/j.arth.2014.03.010 ↗
21. Three-year results of a polycarbonate urethane acetabular bearing in total hip arthroplasty10.1177/1120700019836426 ↗
22. Investigation of the average shape and principal variations of the human talus bone using statistic shape model10.3389/fbioe.2020.00656 ↗
23. The evaluation of artificial talus implant on ankle joint contact characteristics: a finite element study of four subjects
24. Effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, contact pressure, and wear depth due to total ankle replacement10.1177/0954411918823811 ↗
25. Does a PEEK femoral TKA implant preserve intact femoral surface strains compared with CoCr? A preliminary laboratory study10.1007/s11999-016-4801-8 ↗
26. Total talar prosthesis replacement after talar extrusion10.1053/j.jfas.2017.04.005 ↗
27. The basic science of articular cartilage10.1177/1941738109350438 ↗
28. Alumina ceramic talar body prosthesis for idiopathic aseptic necrosis of the talus10.4028/www.scientific.net/KEM.240-242.805 ↗
29. An alumina ceramic total talar prosthesis for avascular necrosis of the talus10.1016/j.fcl.2018.10.004 ↗
30. Tensile engagement of the peri-ankle ligaments in stance phase10.1177/107110070502601212 ↗
31. Tonogai · 2017
32. Custom 3D-printed total talar prostheses restore normal joint anatomy throughout the hindfoot10.1177/1938640018762567 ↗
33. Geometric analysis of the talus and development of a generic talar prosthetic10.1016/j.fas.2016.12.002 ↗
34. Stress shielding after total knee replacement may cause bone resorption in the distal femur10.1302/0301-620X.79B1.0790117 ↗
35. Stemmed femoral knee prostheses: effects of prosthetic design and fixation on bone loss10.3109/17453670209178027 ↗
36. Custom-made total ankle arthroplasty for the salvage of major talar bone loss10.1302/0301-620X.99B2.BJJ-2016-0504.R2 ↗
37. In vivo cartilage contact deformation of human ankle joints under full body weight10.1002/jor.20593 ↗
38. Xia