journal article·2022-09Open access

In vitro method to quantify and visualize mechanical wear in human meniscus subjected to joint loading

Kate J. Benfield, Zachary A. Pinkley, Dylan E. Burruel, Kirk J. Lewis, Daniel S. Ferguson, Trevor J. Lujan

Abstract

The mechanical wear and tear of soft connective tissue from repetitive joint loading is a primary factor in degenerative joint disease, and therefore methods are needed to accurately characterize wear in joint structures. Here, we evaluate the accuracy of using a structured light 3D optical scanning system and modeling software to quantify and visualize volume loss in whole human meniscus subjected to in vitro joint loading. Using 3D printed meniscus replicas with known wear volumes, we determined that this novel imaging method has a mean accuracy of approximately 13 mm3, corresponding to a mean error of less than 7% when measuring meniscal volumetric changes of 0.2 cm3 (size of a pea). The imaging method was then applied to measure the in vitro wear of whole human menisci at four time points when a single cadaveric knee was subjected to one million cycles of controlled joint loading. The medial and lateral menisci reached steady state volumetric reductions of 0.72 cm3 and 0.34 cm3 per million cycles, respectively. Colorimetric maps of linear wear depth revealed high wear and deformation in the posterior regions of both the medial and lateral menisci. For the first time, this study has developed a method to accurately characterize volume loss in whole meniscus subjected to in vitro joint loading. This 3D scanning method offers researchers a new investigative tool to study mechanical wear and joint degeneration in meniscus, and other soft connective tissues.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Contribution of meniscal extrusion and cartilage loss to joint space narrowing in osteoarthritis10.1016/S0009-9260(99)90846-2 ↗
2. Knee wear assessment: 3D scanners used as a consolidated procedure10.3390/ma13102349 ↗
3. Wear distribution detection of knee joint prostheses by means of 3D optical scanners10.3390/ma10040364 ↗
4. In-Vitro Measurement of Static Pressure Distribution in Synovial Joints - Part I: Tibial Surface of the Knee10.1115/1.3138409 ↗
5. Pendulum mass affects the measurement of articular friction coefficient10.1016/j.jbiomech.2012.09.034 ↗
6. Relationship between medial meniscus extrusion and cartilage measurements in the knee by fully automatic three-dimensional MRI analysis
7. Mechanical wear fundamentals and testing, revised and expanded
8. Quantification of meniscal volume by segmentation of 3 T magnetic resonance images10.1016/j.jbiomech.2007.01.016 ↗
9. Development of a preclinical natural porcine knee simulation model for the tribological assessment of osteochondral grafts in vitro10.1016/j.jbiomech.2018.06.014 ↗
10. Simple geometry tribological study of osteochondral graft implantation in the knee10.1177/0954411917751560 ↗
11. The collagen microstructural changes of rat menisci and tibiofemoral cartilages under the influence of mechanical loading: an in vitro wear test of whole joints10.3233/THC-171323 ↗
12. Mechanical, anatomical, and kinematic axis in TKA: concepts and practical applications
13. Rapid, automated imaging of mouse articular cartilage by microCT for early detection of osteoarthritis and finite element modelling of joint mechanics10.1016/j.joca.2014.07.014 ↗
14. Meniscus injury and its surgical treatment does not increase initial whole knee joint friction10.3389/fbioe.2021.779946 ↗
15. Quantification of in vitro wear of a synthetic meniscus implant using gravimetric and micro-CT measurements10.1016/j.jmbbm.2015.05.017 ↗
16. Incidental meniscal findings on knee MRI in middle-aged and elderly persons10.1056/NEJMoa0800777 ↗
17. Clinical significance of meniscal abnormalities on magnetic resonance imaging in an older population10.1016/j.knee.2008.11.006 ↗
18. Gelbart · 2009
19. Tribological role of synovial fluid compositions on artificial joints - a systematic review of the last 10 years10.1002/ls.1266 ↗
20. Dynamic contact mechanics on the tibial plateau of the human knee during activities of daily living10.1016/j.jbiomech.2013.11.003 ↗
21. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee10.1115/1.3138397 ↗
22. Predicted loading on the menisci during gait: the effect of horn laxity10.1016/j.jbiomech.2015.01.047 ↗
23. Quantifying wear depth in hip prostheses using a 3D optical scanner10.1016/j.wear.2017.10.008 ↗
24. 2006 · 13
25. 2009
26. Effect of ACL deficiency on MCL strains and joint kinematics10.1115/1.2720915 ↗
27. Contribution of glycosaminoglycans to viscoelastic tensile behavior of human ligament10.1152/japplphysiol.90748.2008 ↗
28. Luo · 2004
29. The knee meniscus: structure-function, pathophysiology, current repair techniques, and prospects for regeneration10.1016/j.biomaterials.2011.06.037 ↗
30. Dimensional and density data for seeds of cereal grain and other crops10.13031/2013.7859 ↗
31. A multi-directional in vitro investigation into friction, damage and wear of innovative chondroplasty materials against articular cartilage10.1016/j.clinbiomech.2007.03.008 ↗
32. Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics10.1016/j.clinbiomech.2005.01.009 ↗
33. The meniscus-deficient knee: biomechanics, evaluation, and treatment options10.1177/2325967115611386 ↗
34. Effects of a valgus unloader brace in the medial meniscectomized knee joint: a biomechanical study10.1186/s13018-019-1085-1 ↗
35. In vitro response of the natural cadaver knee to the loading profiles specified in a standard for knee implant wear testing10.1016/j.jbiomech.2010.03.042 ↗
36. Importance of preclinical evaluation of wear in hip implant designs using simulator machines10.1016/j.rbo.2016.07.009 ↗
37. New challenges in tribology: wear assessment using 3D optical scanners
38. Techniques for assessment of wear between human cartilage surfaces10.1016/j.wear.2009.03.042 ↗
39. Function of the medial meniscus in force transmission and stability10.1016/j.jbiomech.2015.02.055 ↗
40. Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene10.1002/jor.23745 ↗
41. Articular cartilage and meniscus reveal higher friction in swing phase than in stance phase under dynamic gait conditions10.1038/s41598-019-42254-2 ↗
42. Effect of degenerative and radial tears of the meniscus and resultant meniscectomy on the knee joint: a finite element analysis10.1016/j.jot.2018.12.004 ↗