In silico re-foundation of strain-based healing assessment of fractures treated with an external fixator
Source abstract
Abstract
In the last decades, the literature has demonstrated a renewed interest in finding quantitative and non-invasive techniques for the assessment of bone fractures, by replacing X-ray images. Many different approaches have been proposed from ultrasounds to vibrations. This study aims to numerically assess the foundation of a method firstly proposed in 70' years, based on strain gauges measurements on external fixators for fracture healing monitoring. The theoretical basis consists in the load transfer from the fixator to the bone caused by the callus stiffening during healing. The feasibility is questioned since the level of fixator strain and its variation in invivo conditions should be high enough to be detectable by the sensors. A finite element model of a fractured tibia phantom treated with a monolateral external fixator was developed and validated experimentally. Then, this reference model was used to simulate bone healing and to investigate the sensitivity of virtual strain measurements to callus geometry and loading conditions. The analysis of load distribution among fixator components and their strain maps allowed to identify optimum strain gauges locations which resulted on the pins more distant from the callus, regardless of the simulated conditions. Even in the worst case of a very thin (3 mm) transverse callus in constrained compression conditions, the strain level (≈100 με/100 N) and its variation per week (-50 με/100 N/wk) resulted measurable in the first healing phase, before plateau conditions occurring after about 6 weeks from fixation. A thicker callus causes higher strain levels and can significantly improve measurements, whilst the callus orientation and the loading conditions have a minor effect. However, in case of a free compression loading, also the rods could provide useful indications if sensorized. The results support the method applicability in invivo conditions for the considered test case. Further investigations will be addressed to evaluate the effect of the fixator structure and configuration as well as of patient specific healing timing on the method sensitivity.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone fractures and treatments · Orthopaedic implants and arthroplasty · Bone health and osteoporosis research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. In vivo assessment of regenerate axial stiffness in distraction osteogenesis10.1016/j.orthres.2004.08.024 ↗
2. Biomechanical methods for the assessment of fracture repair10.1016/j.injury.2014.04.006 ↗
3. Monitoring fracture site properties with external fixation10.1115/1.3138395 ↗
4. Standardized loads acting in knee implants10.1371/journal.pone.0086035 ↗
5. Bizzoca · 2020
6. External fixation of the lower extremities: biomechanical perspective and recent innovations10.1016/j.injury.2019.03.041 ↗
7. Measurement of the stiffness of fracture callus in vivo. A theoretical study10.1016/0021-9290(72)90021-8 ↗
8. Telemetering in vivo loads from nail plate implants10.1016/0021-9290(82)90046-X ↗
9. Utilisation des jauges extensometriques pour la mesure de la consolidation des fractures du tibia traitees par enclouage centromidullaire
10. Twenty years experience in fracture healing measurement with strain gauges10.3928/0147-7447-19841201-08 ↗
11. External fixation of diaphyseal fractures of the tibia10.1016/S0268-0890(03)00068-9 ↗
12. Monitoring and healing analysis of 100 tibial shaft fractures10.1007/s00423-002-0306-x ↗
13. Fracture healing assessment based on impact testing: in-vitro simulation and monitoring of the healing process of a tibial fracture with external fixator10.1142/S1758825117500983 ↗
14. investigation on the feasability of bone stiffness assessment from in-vivo tests
15. Incidence, costs and predictors of non-union, delayed union and mal-union following long bone fracture10.3390/ijerph15122845 ↗
16. Telemetric in vivo measurement of compressive forces during consolidation in a rabbit model
17. Elastic properties of woven bone: effect of mineral content and collagen fibrils orientation
18. Relative stiffness, transverse displacement and dynamization in comparable external fixators10.1016/S0268-0033(92)90006-P ↗
19. A concert between biology and biomechanics: the influence of the mechanical environment on bone healing10.3389/fphys.2016.00678 ↗
20. Monitoring in vivo load transmission through an external fixator10.1007/s10439-009-9889-5 ↗
21. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures10.1007/s00590-018-2190-2 ↗
22. The use of strain gauges to measurebone fracture healing—a review10.1016/S0268-0890(05)80065-9 ↗
23. A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading10.1016/S0021-9290(02)00086-6 ↗
24. Preliminary Study: Monitoring of Healing Stages of Bone Fracture Utilizing UWB Pulsed Radar Technique10.1109/ANTEM.2018.8572872 ↗
25. Radiographic investigation of the distal extension of fractures into the articular surface of the tibia (the RIDEFAST study)10.1097/BOT.0000000000000938 ↗
26. The biology of fracture healing10.1016/j.injury.2011.03.031 ↗
27. Vibration testing procedures for bone stiffness assessment in fractures treated with external fixation10.1007/s10439-016-1769-1 ↗
28. In-vivo impact testing on a lengthened femur with external fixation: a future option for non-invasive fracture healing monitoring?10.1098/rsif.2018.0068 ↗
29. Fracture healing monitoring by impact tests: single case study of a fractured tibia with external fixator10.1109/JTEHM.2019.2901455 ↗
30. Mattei · 2019 · 8
31. A numerical approach to the biomechanical analysis of bone fracture healing10.1016/0141-5425(89)90102-7 ↗
32. The relative incidence of fracture non-union in the Scottish population (5.17 million): a 5-year epidemiological study10.1136/bmjopen-2012-002276 ↗
33. Influence of fracture geometry on bone healing under locking plate fixations: a comparison between oblique and transverse tibial fractures10.1016/j.medengphy.2016.07.007 ↗
34. In vivo mechanical characterization of the distraction callus during bone consolidation10.1007/s10439-015-1330-7 ↗
35. The vibrational mode of the tibia and assessment of bone union in experimental fracture healing using the impulse response method10.1016/1350-4533(96)00010-0 ↗
36. Monitoring of fracture healing by lateral and axial vibration analysis10.1016/0021-9290(90)90060-G ↗
37. Integrating sensing elements on external fixators for healing assessment of fractured femur10.1002/stc.1843 ↗
38. Three-dimensional load measurements in an external fixator10.1016/j.jbiomech.2003.12.025 ↗
39. Functional load of plates in fracture fixation in vivo and its correlate in bone healing10.1016/S0020-1383(00)80042-X ↗
40. A review of computational models of bone fracture healing10.1007/s11517-017-1701-3 ↗
41. Investigation of load transfer process between external fixator and bone model by experimental and finite element methods