journal article·2021-10

Effect of specific retention biomaterials for ball attachment on the biomechanical response of single implant-supported overdenture: A finite element analysis

Mona Gibreel, Ahmed Sameh, Salah Hegazy, Timo O. Närhi, Pekka K. Vallittu, Leila Perea-Lowery

Publisher page

Abstract

Purpose The purpose of this finite element analysis (FEA) was to evaluate the effect of specific retention biomaterials with different elastic modulus on the biomechanical response to the axial and off-axial biting loads of a mandibular midline single implant-supported overdenture (SIO) model. Methods Five 3-dimensional (3D) finite element models of an edentulous mandible with SIO were designed as follows: model M with a titanium retentive element for ball attachment, model P with a PEEK retentive element, model S with a silicone resilient liner retentive element, model T with a thermoplastic acrylic resin retentive element made from a CAD-CAM material, and model A with a polyacetal resin retentive element. Posterior bilateral vertical load (PV) at the 1st molar areas and anterior oblique load (AO) at the incisal edge of the mandibular central incisors at a 30-degree angle of 100 N were applied. Stress values were recorded. Results Stress values were higher for all models under (AO) loading than under (PV) loading. Model M recorded the highest stress values on the implant, its components, cortical, and cancellous bone under both loading conditions. Under (AO) loading condition, the ball abutment von Mises stress value in model S was almost 7 times lower than that of model M (19 and 130 MPa respectively) and the other 3 models (P, T, and A) (119, 121, and 120 MPa respectively). However, model S recorded the highest value of denture base stress at the attachment area. Conclusions The elastic modulus of retention materials can affect stresses generated on the implant overdenture components and supporting structures.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (72)

Show source-provided references
1. The use of processed silicone to retain the implant-supported tissue-borne overdenture10.1016/0022-3913(92)90457-L ↗
2. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism10.1046/j.1365-2842.2002.00872.x ↗
3. Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems10.1111/j.1600-0501.2010.02004.x ↗
4. Stress distribution of single-implant-retained overdenture reinforced with a framework: a finite element analysis study10.1016/j.prosdent.2017.07.016 ↗
5. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis10.1016/S0022-3913(08)60259-0 ↗
6. Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible--a computed tomography-based three-dimensional finite element analysis10.1016/j.jbiomech.2013.02.008 ↗
7. A 3D finite element analysis of glass fiber reinforcement designs on the stress of an implant-supported overdenture10.1016/j.prosdent.2019.02.010 ↗
8. Wear of ceramic and titanium ball attachments in subjects with an implant-retained overdenture: a controlled clinical trial10.1016/S0022-3913(12)60035-3 ↗
9. The effect of BisGMA on cyclooxygenase-2 expression, PGE2 production and cytotoxicity via reactive oxygen species- and MEK/ERK-dependent and -independent pathways10.1016/j.biomaterials.2009.04.034 ↗
10. Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments10.1111/j.1365-2842.2004.01407.x ↗
11. Mandibular overdentures anchored to single implants: a five-year prospective study10.1016/S0022-3913(97)70120-3 ↗
12. A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations10.1016/j.medengphy.2007.02.005 ↗
13. Clinical viability of single implant-retained mandibular overdentures: a systematic review and meta-analysis10.1016/j.ijom.2018.01.021 ↗
14. The influence of clip material and cross sections of the bar framework associated with vertical misfit on stress distribution in implant-retained overdentures10.11607/ijp.3627 ↗
15. Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading10.1007/s11517-015-1426-0 ↗
16. The effect of using different crown and implant materials on bone stress distribution: a finite element study10.1097/01.OMX.0000444266.10130.4c ↗
17. A finite element study on stress distribution of two different attachment designs under implant supported overdenture10.1016/j.sdentj.2015.03.001 ↗
18. Biomechanics of 3-implant-supported and 4-implant-supported mandibular screw-retained prostheses: a 3D finite element analysis study10.1016/j.prosdent.2020.01.015 ↗
19. Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar- and implant-retained mandibular overdentures: a 3-year randomized clinical study
20. Mandibular denture base deformation with locator and ball attachments of implant-retained overdentures10.1111/jopr.12356 ↗
21. Impact of implant support for mandibular dentures on satisfaction, oral and general health-related quality of life: a meta-analysis of randomized-controlled trials10.1111/j.1600-0501.2008.01693.x ↗
22. Effects of overdenture retention designs and implant orientations on load transfer characteristics10.1016/S0022-3913(96)90441-2 ↗
23. The physical properties of a polyacetal denture resin10.1016/0267-6605(94)90135-X ↗
24. Bone's mechanostat: a 2003 update10.1002/ar.a.10119 ↗
25. A 2003 update of bone physiology and Wolff's Law for clinicians
26. Use of polyethylene terephthalate as a prosthetic component in the prosthesis on an overdenture implant10.1016/j.msec.2019.01.136 ↗
27. Load-bearing capacity of simulated Locator-retained overdenture system10.1016/j.prosdent.2018.04.009 ↗
28. Fracture incidence in mandibular overdentures retained by one or two implants10.1016/S0022-3913(10)60026-1 ↗
29. Biofilm formation on the surface of modern implant abutment materials10.1111/clr.12454 ↗
30. Bite force and oral function in patients with osseointegrated oral implants10.1111/j.1600-0722.1977.tb00554.x ↗
31. Three-year clinical outcome of single implant-retained mandibular overdentures--results of preliminary prospective study10.1016/j.jdent.2011.07.007 ↗
32. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone10.1016/S0300-5712(01)00057-4 ↗
33. Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study10.1016/j.prosdent.2017.03.008 ↗
34. In vitro study of reduction of stress transferred onto tissues around implants using a resilient material in maxillary implant overdentures
35. Stress distribution of overdenture using odd number implants - a Finite Element Study10.1016/j.jmbbm.2019.06.030 ↗
36. Survival and complications of single dental implants in the edentulous mandible following immediate or delayed loading: a randomized controlled clinical trial10.1177/0022034517736063 ↗
37. A comparative evaluation of stress distribution with two attachment systems of varying heights in a mandibular implant-supported overdenture: a three-dimensional finite element analysis
38. Development of new attachment system with soft lining material for implant-retained complete denture
39. The symphyseal single-tooth implant for anchorage of a mandibular complete denture in geriatric patients: a clinical report
40. Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis10.4103/0970-9290.199587 ↗
41. A prospective study of immediately loaded single implant-retained mandibular overdentures: preliminary one-year results10.1016/S0022-3913(07)60016-X ↗
42. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis10.1016/j.jdent.2012.11.008 ↗
43. Biomechanical rationale for a single implant-retained mandibular overdenture: an in vitro study10.1111/j.1600-0501.2007.01425.x ↗
44. Martin · 2015
45. Five years follow-up of mandibular 2-implant overdentures on locator or ball abutments: implant results, patient-related outcome, and prosthetic aftercare10.1111/cid.12840 ↗
46. Photoelastic stress distribution produced by different retention systems for a single-implant mandibular overdenture10.1111/jopr.12269 ↗
47. A 2-year prospective study of single-implant mandibular overdentures: patient-reported outcomes and prosthodontic events10.1111/clr.13151 ↗
48. Effect of implant height differences on different attachment types and peri-implant bone in mandibular two-implant overdentures: 3D finite element study10.1563/AAID-JOI-D-13-00239 ↗
49. Six-year clinical outcome of single implant-retained mandibular overdentures--a pilot study10.1111/clr.12427 ↗
50. Characterization of the mechanical properties of CAD/CAM polymers for interim fixed restorations10.4012/dmj.2019-042 ↗
51. Probabilistic analysis of peri-implant strain predictions as influenced by uncertainties in bone properties and occlusal forces10.1111/j.1600-0501.2007.01384.x ↗
52. Biomechanical behavior of 2-implant- and single-implant-retained mandibular overdentures with conventional or mini implants10.1016/j.prosdent.2017.12.012 ↗
53. Effect of two different soft liners and thicknesses mediating stress transfer for immediately loaded 2-implant supported mandibular overdentures: a finite element analysis study10.1016/j.prosdent.2016.01.031 ↗
54. Comparison of retention of clasps made of different materials using three-dimensional finite element analysis
55. A comparative in vitro study on the retention and stability of implant-supported overdentures
56. Oral mucosa pressure caused by mandibular implant overdenture with different types of attachments10.1016/j.jpor.2019.06.003 ↗
57. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture10.2298/VSP110526021S ↗
58. Effects of attachment type on the mobility of implant-stabilized overdentures--an in vitro study
59. Biological-data-based finite-element stress analysis of mandibular bone with implant-supported overdenture10.1016/j.compbiomed.2014.08.018 ↗
60. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants10.1080/10255842.2017.1302432 ↗
61. Retention force of differently fabricated telescopic PEEK crowns with different tapers10.4012/dmj.2015-249 ↗
62. Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures
63. Effects of clip materials on stress distribution to maxillary implant overdentures with bar attachments10.1016/j.prosdent.2015.07.017 ↗
64. In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability
65. Attachment systems for implant retained overdentures: a literature review10.1097/01.id.0000202419.21665.36 ↗
66. Long-term results of mandibular implants supporting an overdenture: implant survival, failures, and crestal bone level changes
67. Evaluation of stress distribution on mandibular implant-supported overdentures with different bone heights and attachment types: a 3D finite element analysis10.1563/aaid-joi-D-19-00076 ↗
68. Retention force and deformation of an innovative attachment model for mini-implant-retained overdentures10.1016/j.prosdent.2018.04.010 ↗
69. Flexural properties of acrylic resin polymers reinforced with unidirectional and woven glass fibers10.1016/S0022-3913(99)70276-3 ↗
70. An overview of development and status of fiber-reinforced composites as dental and medical biomaterials10.1080/23337931.2018.1457445 ↗
71. Dynamic mechanical thermal analysis of denture soft lining materials10.1016/0142-9612(95)00330-4 ↗
72. 1996