journal article·2018-11

Flexural and torsional properties of a glass fiber-reinforced composite diaphyseal bone model with multidirectional fiber orientation

Kalle A. Dahl, Niko Moritz, Pekka K. Vallittu

Publisher page

Abstract

Although widely used, metallic implants have certain drawbacks in reconstructive bone surgery. Their high stiffness in respect to cortical bone can lead to complications which include periprosthetic fractures and aseptic loosening. In contrast to metallic alloys, fiber-reinforced composites (FRC) composed of a thermoset polymer matrix reinforced with continuous E-glass fibers have elastic properties matching those of bone. We investigated the mechanical properties of straight FRC tubes and FRC bone models representing the diaphysis of rabbit femur prepared from glass fiber/bisphenol A glycidyl methacrylate (BisGMA) - triethylene glycol dimethacrylate (TEGDMA) composite in three-point bending and torsion. Three groups of straight FRC tubes with different fiber orientations were mechanically tested to determine the best design for the FRC bone model. Tube 1 consisted most axially oriented unidirectional fiber roving and fewest bidirectional fiber sleevings. Fiber composition of tube 3 was the opposite. Tube 2 had moderate composition of both fiber types. Tube 2 resisted highest stresses in the mechanical tests and its fiber composition was selected for the FRC bone model. FRC bone model specimens were then prepared and the mechanical properties were compared with those of cadaver rabbit femora. In three-point bending, FRC bone models resisted 39-54% higher maximum load than rabbit femora with similar flexural stiffness. In torsion, FRC bone models resisted 31% higher maximum torque (p < 0.001) and were 38% more rigid (p = 0.001) than rabbit femora. Glass fiber-reinforced composites have good biocompatibility and from a biomechanical perspective, they could be used even in reconstruction of segmental diaphyseal defects. Development of an implant applicable for clinical use requires further studies.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone fractures and treatments · Bone health and osteoporosis research · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. The effect of high fiber fraction on some mechanical properties of unidirectional glass fiber-reinforced composite10.1016/j.dental.2010.11.007 ↗
2. The outcome and functional results of diaphyseal endoprostheses after tumour excision10.1302/0301-620X.78B4.0780652 ↗
3. Craniofacial bone reconstruction with bioactive fiber-reinforced composite implant10.1002/hed.23370 ↗
4. "Endoprosthetic replacement of diaphyseal bone defects. Long-term results10.1007/s00264-004-0614-6 ↗
5. Mechanical symmetry of rabbit bones studied by bending and indentation testing10.2460/ajvr.1996.57.12.1786 ↗
6. Case reports: management of large segmental tibial defects using a cylindrical mesh cage10.1097/01.blo.0000223982.29208.a4 ↗
7. Osseointegration of fiber-reinforced composite implants: histological and ultrastructural observations10.1016/j.dental.2014.08.361 ↗
8. Outcomes of a modular intercalary endoprosthesis as treatment for segmental defects of the femur, tibia, and humerus10.1007/s11999-015-4588-z ↗
9. Basic composition and structure of bone
10. Dual-energy computed tomography-how accurate is gemstone spectrum imaging metal artefact reduction? Its application to orthopedic metal implants10.1097/RCT.0000000000000300 ↗
11. Internal femoral forces and moments during running: implications for stress fracture development10.1016/j.clinbiomech.2008.06.011 ↗
12. Composite technology in load-bearing orthopaedic implants10.1016/S0142-9612(97)00217-2 ↗
13. Use of carbon-fiber-reinforced composite implants in orthopedic surgery10.3928/01477447-20141124-05 ↗
14. Femoral diaphyseal endoprosthetic reconstruction after segmental resection of primary bone tumours10.1302/0301-620X.92B6.23449 ↗
15. Evaluation of the biocompatibility of new fiber-reinforced composite materials for craniofacial bone reconstruction10.1097/SCS.0000000000002925 ↗
16. Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens10.1007/s00402-002-0465-9 ↗
17. The efficacy of cylindrical titanium mesh cage for the reconstruction of a critical-size canine segmental femoral diaphyseal defect10.1002/jor.20154 ↗
18. What is the price to pay for a free fibula flap? A systematic review of donor-site morbidity following free fibula flap surgery10.1097/PRS.0b013e3182402d9a ↗
19. Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty10.3109/17453674.2013.859419 ↗
20. Mechanical properties and in vivo performance of load-bearing fiber-reinforced composite intramedullary nails with improved torsional strength10.1016/j.jmbbm.2014.08.020 ↗
21. Multi-layer porous fiber-reinforced composites for implants: in vitro calcium phosphate formation in the presence of bioactive glass10.1016/j.dental.2012.08.005 ↗
22. Intercalary reconstructions after bone tumor resections: a review of treatments10.1007/s00590-017-1985-x ↗
23. Outcomes of cranioplasty with synthetic materials and autologous bone grafts10.1016/j.wneu.2015.01.014 ↗
24. A glass fiber-reinforced composite – bioactive glass cranioplasty implant: a case study of an early development stage implant removed due to a late infection10.1016/j.jmbbm.2015.10.030 ↗
25. Biomedical applications of polymer-composite materials: a review10.1016/S0266-3538(00)00241-4 ↗
26. Outcome of the intramedullary diaphyseal segmental defect fixation system for bone tumors10.1002/jso.21893 ↗
27. The effects of ovariectomy on bone mineral density, geometrical, and biomechanical characteristics in the rabbit femur10.3415/VCOT-08-09-0085 ↗
28. The effects of nail rigidity on fracture healing in rats with osteoporosis10.1080/17453670902807490 ↗
29. Effects of implantable biomaterials on radiation dosimetry10.1002/(SICI)1097-0347(199708)19:5<384::AID-HED4>3.0.CO;2-W ↗
30. Donor-site morbidity with use of vascularized autogenous fibular grafts10.2106/00004623-199602000-00006 ↗
31. Bioactive glass-containing cranial implants: an overview10.1007/s10853-017-0888-x ↗
32. Fiber glass–bioactive glass composite for bone replacing and bone anchoring implants10.1016/j.dental.2015.01.003 ↗
33. Less rigid internal fixation plates: historical perspectives and new concepts10.1002/jor.1100010412 ↗
34. Antibacterial effects and dissolution behavior of six bioactive glasses10.1002/jbm.a.32564 ↗
35. Development of a multi-component fiber-reinforced composite implant for load-sharing conditions10.1016/j.medengphy.2008.11.006 ↗