Bone regeneration into side openings and hollow inner channel of a dental implant
Source abstract
Abstract
The current study examined whether bone can regenerate into an open space fabricated inside the metal implant and maintain its quantity and quality at the early post-implantation healing periods. 12 conventional one piece screw type titanium dental implants (control group) and 12 hybrid dental implants with spiral side openings (0.58 mm wide) connected to hollow inner channel (experimental group) were bilaterally placed in each quadrant at the P3, P4 and M1 positions in mandible of 4 adult beagles following 2 months of post-extraction healing. Fluorescent bone labels to qualitatively evaluate newly formed bone tissues were administered at 2 and 4 weeks of post-implantation periods, respectively. 3 control and 3 experimental bone-implant constructs for each animal were dissected from 2 animals at each 3 and 6 weeks of post-implantation healing periods. Undecalcified specimens were prepared from each construct for histological analyses to measure bone-to-implant contact (BIC) and interfacial bone area (BA), and also for nanoindentation and scanning electron microscopy to assess elastic modulus (E) and composition of bone tissues surrounding the implants, respectively. A substantial amount of newly formed bone tissues were observed at the implant interfaces of both implant groups. Bone tissues successfully regenerate through the side openings and hollow inner channel of the experimental implant as early as 3 weeks of post-implantation healing. The E values of the newly formed bone tissues were measured comparable to those of normal bone tissues. The current results indicate that the new hybrid implant can conduct bone regeneration into the inner architecture, which likely improves stability of the implant system by enhancing integrity of implant with interfacial bone.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Greater magnitude of turnover suppression occurs earlier after treatment initiation with risedronate than alendronate10.1016/j.bone.2010.07.011 ↗
2. Mechanical properties of human bone surrounding plateau root form implants retrieved after 0.3-24 years of function10.1002/jbm.b.32786 ↗
3. A 5-year longitudinal study of the clinical effectiveness of ITI solid-screw implants in the treatment of mandibular edentulism
4. De novo alveolar bone formation adjacent to endosseous implants10.1034/j.1600-0501.2003.00972.x ↗
5. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions10.1111/prd.12179 ↗
6. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
7. Biomaterials and biomechanics in dental implant design
8. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants10.1034/j.1600-0501.1997.080302.x ↗
9. Long-term dental implant success and survival--a clinical study after an observation period up to 6 years
10. Remodeling dynamics of bone supporting rigidly fixed titanium implants: a histomorphometric comparison in four species including humans10.1097/00008505-199500440-00002 ↗
11. Failed dental implants: diagnosis, removal and survival of reimplantations10.14219/jada.2014.28 ↗
12. Nonsubmerged implants in the treatment of the edentulous lower jaw: a 5-year prospective longitudinal study of ITI hollow screws10.1111/j.1708-8208.2001.tb00125.x ↗
13. Heterogeneity of bone lamellar-level elastic moduli10.1016/S8756-3282(00)00268-4 ↗
14. A review on alveolar ridge preservation following tooth extraction10.1016/S1532-3382(12)70029-5 ↗
15. Basis of bone metabolism around dental implants during osseointegration and peri-implant bone loss10.1002/jbm.a.36060 ↗
16. Effect of guided bone regeneration on bone quality surrounding dental implants10.1016/j.jbiomech.2018.08.011 ↗
17. Effect of implant design on survival and success rates of titanium oral implants: a 10-year prospective cohort study of the ITI dental implant system10.1111/j.1600-0501.2004.00983.x ↗
18. Differences between buccal and lingual bone quality and quantity of peri-implant regions10.1016/j.jmbbm.2015.12.036 ↗
19. Kim · 2017
20. Relationships of viscosity with contact hardness and modulus of bone matrix measured by nanoindentation10.1115/1.4000936 ↗
21. Regional variation of bone tissue properties at the human mandibular condyle10.1016/j.bone.2015.04.024 ↗
22. Mechanical properties of bone tissues surrounding dental implant systems with different treatments and healing periods10.1007/s00784-016-1734-2 ↗
23. Determinants of ovine compact bone viscoelastic properties: effects of architecture, mineralization, and remodeling10.1016/j.bone.2004.04.006 ↗
24. Measurement of hardness and elastic modulus by instrumented indentation: advances in understanding and refinements to methodology10.1557/jmr.2004.19.1.3 ↗
25. Osteocyte density in the peri-implant bone of implants retrieved after different time periods (4 weeks to 27 years)10.1002/jbm.b.33000 ↗
26. A microscopical evaluation of 24 retrieved failed hollow implants10.1016/S0142-9612(98)00194-X ↗
27. Improvements in implant dentistry over the last decade: comparison of survival and complication rates in older and newer publications10.11607/jomi.2014suppl.g5.2 ↗
28. The development of the ITI DENTAL IMPLANT SYSTEM. Part 1: a review of the literature10.1034/j.1600-0501.2000.011S1008.x ↗
29. Age- and menopause-related bone loss compromise cortical and trabecular microstructure10.1093/gerona/glt071 ↗
30. 50 years of scanning electron microscopy of bone-a comprehensive overview of the important discoveries made and insights gained into bone material properties in health, disease, and taphonomy10.1038/s41413-019-0053-z ↗
31. 3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface10.1016/j.actbio.2015.11.013 ↗
32. Standardization · 2007
33. Histologic study of failed hollow implants
34. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment10.1016/j.msec.2015.10.069 ↗
35. Long-term evaluation of hollow screw and hollow cylinder dental implants: clinical and radiographic results after 10 years10.1902/jop.2006.040346 ↗
36. Advances in bone augmentation to enable dental implant placement: consensus report of the sixth European workshop on periodontology10.1111/j.1600-051X.2008.01268.x ↗
37. The role of collagen in bone strength10.1007/s00198-005-2035-9 ↗
38. Ridge preservation after tooth extraction10.1111/j.1600-0501.2012.02560.x ↗
39. Analysis of factors influencing bone ingrowth into three-dimensional printed porous metal scaffolds: a review10.1016/j.jallcom.2017.05.079 ↗