journal article·2020-02Open access

Tribocorrosion behaviour of pure titanium in bovine serum albumin solution: A multiscale study

Evangelos Liamas, Owen R.T. Thomas, Anna Igual Muñoz, Zhenyu J. Zhang

Abstract

Tribocorrosion behaviour of pure titanium in phosphate buffer saline (PBS) solution has been investigated systematically as a function of surface chemistry and bovine serum albumin (BSA) content in the solution. A ball-on-disk tribometer coupled with an electrochemical cell was used to study the effect of electrochemical conditions (i.e. anodic and cathodic applied potentials, as well as at open circuit potential) on the tribocorrosion response of titanium. It was found that the main material loss is due to mechanical wear caused by plastic deformation. The mechanical wear was higher under anodic conditions than under cathodic, partially due to an increased presence of debris particles at the sliding interface that act as third bodies. The effect of BSA on the interaction between alumina and titanium, as well as the behaviour of third bodies during the mechanical wear, were investigated in the nanoscale level using atomic force microscopy based force spectroscopy. It was found that the presence of BSA affects tribocorrosion in various ways. Firstly, it increases the repassivation rate of the oxide film by inhibiting the cathodic reactions and accelerating the anodic reactions. Secondly, it increases the mechanical wear by increasing the adhesion of debris onto the sliding interface, while at anodic conditions it increases the rolling efficiency of the debris particles that further enhances the mechanical wear.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Contact modeling forces10.1016/S0301-679X(00)00063-3 ↗
2. Askeland · 2015
3. Tribocorrosion of pulsed plasma nitrided CoCrMo implant alloy10.1007/s11249-012-0047-0 ↗
4. Direct electrochemical reduction of titanium dioxide to titanium in molten calcium chloride10.1038/35030069 ↗
5. The cathodic behavior of titanium: serum effect10.1002/jbm.b.31984 ↗
6. Biomedical applications of titanium and its alloys10.1007/s11837-008-0031-1 ↗
7. Composition of interstitial fluid10.1093/clinchem/41.10.1522 ↗
8. Metal ion release from metal implants10.1016/j.msec.2004.08.018 ↗
9. Effects of biological factors on the repassivation current of titanium10.2320/matertrans.45.1635 ↗
10. The influence of proteins on the fretting-corrosion behaviour of a Ti6Al4V alloy10.1016/j.wear.2006.03.032 ↗
11. Calibration of atomic force microscope tips10.1063/1.1143970 ↗
12. Conjoint corrosion and wear in titanium alloys10.1016/S0142-9612(98)00229-4 ↗
13. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions10.1016/S0142-9612(98)00217-8 ↗
14. The corrosion resistance of pure titanium in organic acids10.1016/S0142-9612(01)00040-0 ↗
15. Landolt · 2011
16. Third body effects and material fluxes in tribocorrosion systems involving a sliding contact10.1016/S0043-1648(03)00561-1 ↗
17. The entrapment of corrosion products from CoCr implant alloys in the deposits of calcium phosphate: a comparison of serum, synovial fluid, albumin, EDTA, and water10.1002/jor.20198 ↗
18. Electrochemical behaviour of titanium in protein-containing saline solution10.1039/C9RA05988A ↗
19. Tribocorrosion mechanisms of Ti6Al4V biomedical alloys in artificial saliva with different pHs10.1088/0022-3727/46/40/404003 ↗
20. Mechanical and chemical mechanisms in the tribocorrosion of a Stellite type alloy10.1016/j.wear.2013.04.007 ↗
21. Study of corrosion in biocompatible metals for implants: a review10.1016/j.jallcom.2017.01.196 ↗
22. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
23. XPS and EIS study of the passive film formed on orthopaedic Ti-6Al-7Nb alloy in Hank's physiological solution10.1016/j.electacta.2007.12.041 ↗
24. Electrochemical properties, chemical composition and thickness of passive film formed on novel Ti-20Nb-10Zr-5Ta alloy10.1016/j.electacta.2013.03.086 ↗
25. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
26. The role of passive oxide films on the degradation of steel in tribocorrosion systems10.1016/S0043-1648(99)00056-3 ↗
27. Dry sliding wear mechanisms of the Ti6Al4V alloy10.1016/S0043-1648(96)07454-6 ↗
28. Interactive effects of albumin and phosphate ions on the corrosion of CoCrMo implant alloy10.1149/1.2764238 ↗
29. Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys10.1007/s10856-010-4224-0 ↗
30. Electrochemical quartz crystal microbalance and x-ray photoelectron spectroscopy study of cathodic reactions in bovine serum albumin containing solutions on a physical vapour deposition CoCrMo biomedical alloy10.1016/j.electacta.2015.08.017 ↗
31. Evaluated material properties for a sintered alpha-alumina10.1111/j.1151-2916.1997.tb03074.x ↗
32. Mechanical properties of biomedical titanium alloys10.1016/S0921-5093(97)00806-X ↗
33. Biologically and mechanically biocompatible titanium alloys10.2320/matertrans.L-MRA2008828 ↗
34. Green tribology: principles, research areas and challenges
35. EQCM study of anodic film growth on valve metals10.1149/1.1819896 ↗
36. Tribocorrosion behavior of beta titanium biomedical alloys in phosphate buffer saline solution10.1016/j.jmbbm.2015.02.016 ↗
37. Pourbaix · 1974
38. Biomaterial properties of titaniumin dentistry10.1016/j.job.2015.08.001 ↗
39. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
40. Corrosion and tribocorrosion of hafnium in simulated body fluids10.1002/jbm.b.33097 ↗
41. Base metal alloys used for dental restorations and implants10.1016/j.cden.2007.04.001 ↗
42. Effects of proteins and pH on tribocorrosion performance of cast CoCrMo – a combined electrochemical and tribological study10.1179/175158309X408315 ↗
43. A brief review: biomaterials and their application
44. Rotating ring-disk electrochemical quartz crystal microbalance: a new tool for in situ studies of oxide film formation10.1016/j.jelechem.2003.11.047 ↗
45. Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids10.1016/j.corsci.2008.04.002 ↗