Design consideration of a novel polymeric transcatheter heart valve through computational modeling
Source abstract
Abstract
Transcatheter heart valve replacement is becoming a more routine procedure, and this is further supported by positive outcomes from studies involving low-risk patients. Nevertheless, the lack of long-term transcatheter heart valve (TAV) durability is still one of the primary concerns. As a result, more research has been focused on improving durability through various methods such as valve design, computational modeling, and material selection. Recent advancements in polymeric valve fabrication showed that linear low-density polyethylene (LLDPE) could be used as leaflet material for transcatheter heart valves. In this paper, a parametric study of computational simulations showed stress distribution on the leaflets of LLDPE-TAV under diastolic load, and the results were used to improve the stent design. The in silico experiment also tested the effect of shock absorbers in terms of valve durability. The results demonstrated that altering specific stent angles can significantly lower peak stress on the leaflets (13.8 vs. 6.07 MPa). Implementing two layers of shock absorbers further reduces the stress value to 4.28 MPa. The pinwheeling index was assessed, which seems to correlate with peak stress. Overall, the parametric study and the computational method can be used to analyze and improve valve durability.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac Valve Diseases and Treatments · Cardiovascular Function and Risk Factors · Infective Endocarditis Diagnosis and Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. A geometry optimization framework for transcatheter heart valve leaflet design10.1016/j.jmbbm.2019.103491 ↗
2. Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices10.1016/j.biomaterials.2014.09.013 ↗
3. Failure of Hancock pericardial xenografts: is prophylactic bioprosthetic replacement justified?10.1016/0003-4975(91)90859-O ↗
4. A late evaluation of flexible teflon prostheses utilized for total aortic valve replacement10.1016/S0022-5223(19)33284-2 ↗
5. Durability optimization of novel hyaluronic acid enhanced polymeric transcatheter aortic valves, American college of cardiology10.1016/S0735-1097(21)04590-3 ↗
6. Transcatheter heart valves: a biomaterials perspective10.1002/adhm.202100115 ↗
7. Development and fabrication of vapor cross-linked hyaluronan–polyethylene interpenetrating polymer network as a biomaterial10.1021/acsami.9b03437 ↗
8. Modes of failure in explanted Mitroflow pericardial valves10.1016/j.athoracsur.2011.06.092 ↗
9. In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve10.1115/1.4023235 ↗
10. A parametric computational study of the impact of non-circular configurations on bioprosthetic heart valve leaflet deformations and stresses: possible implications for transcatheter heart valves10.1007/s13239-016-0259-9 ↗
11. The effect of fundamental curves on geometric orifice and coaptation areas of polymeric heart valves10.1016/j.jmbbm.2020.104039 ↗
12. Influence of stent height upon stresses on the cusps of closed bioprosthetic valves10.1016/0021-9290(86)90199-5 ↗
13. Heart valves from polymeric fibers: potential and limits10.23736/S0021-9509.20.11604-5 ↗
14. In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve10.1016/j.jmbbm.2019.06.016 ↗
15. Ionescu-Shiley bovine pericardial bioprostheses. Histologic and ultrastructural studies
16. Assessment of a siloxane poly(urethane-urea) elastomer designed for implantable
17. Analysis of the changing economics of US hospital transcatheter aortic valve replacement programs10.1016/j.mayocp.2020.04.012 ↗
18. Simulated transcatheter aortic valve deformation: a parametric study on the impact of leaflet geometry on valve peak stress10.1002/cnm.2814 ↗
19. Mechanical considerations for polymeric heart valve development: biomechanics, materials, design and manufacturing10.1016/j.biomaterials.2019.119493 ↗
20. Bio-prosthetic heart valve stress analysis: impacts of leaflet properties and stent tip deflection
21. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties10.1007/s10237-013-0532-x ↗
22. Transcatheter valve underexpansion limits leaflet durability: implications for valve-in-valve procedures10.1007/s10439-016-1738-8 ↗
23. The flexural rigidity of the aortic valve leaflet in the commissural region10.1016/j.jbiomech.2005.10.026 ↗
24. Materials and manufacturing perspectives in engineering heart valves: a review10.1016/j.mtbio.2019.100038 ↗
25. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients10.1056/NEJMoa1816885 ↗
26. Hemocompatibility and hemodynamics of novel hyaluronan–polyethylene materials for flexible heart valve leaflets10.1007/s13239-013-0171-5 ↗
27. Tricuspid leaflet aortic valve prosthesis10.1161/01.CIR.33.4S1.I-124 ↗
28. Experimental results with a prosthetic aortic valve10.1016/S0096-5588(20)30134-3 ↗
29. In vitro durability and stability testing of a novel polymeric transcatheter aortic valve10.1097/MAT.0000000000000980 ↗
30. Sarraf · 2019 · 85
31. Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration10.1161/01.CIR.76.3.618 ↗
32. Fatigue criteria under combined stresses or strains10.1115/1.3224995 ↗
33. Influence of patient-specific characteristics on transcatheter heart valve neo-sinus flow: an in silico study10.1007/s10439-020-02532-x ↗
34. Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve10.1016/j.jmbbm.2010.09.009 ↗
35. Effects of hemodynamic conditions and valve sizing on leaflet bending stress in self-expanding transcatheter aortic valve: an in vitro study10.1111/aor.13654 ↗
36. Thubrikar · 1990
37. Computational optimization study of transcatheter aortic valve leaflet design using porcine and bovine leaflets
38. Primary tissue failure in pericardial heart valves10.1016/S0022-5223(19)36249-X ↗
39. Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves10.1093/icvts/ivaa037 ↗
40. Yeats · 2019
41. Acute structural failure of the Trifecta aortic valve bioprosthesis10.1016/j.hlc.2017.03.157 ↗