Primary stability of dental implants is the initial mechanical engagement of the implant with its adjacent bone. Implantation and the subsequent loading may cause mechanical damage in the peripheral bone, which ultimately reduces the stability of the implant. This study aimed at evaluating primary stability of dental implants through applying stepwise compressive displacement-controlled, loading-unloading cycles to obtain overall stiffness and dissipated energy of the bone-implant structure; and quantifying induced plastic strains in surrounding bone using digital volume correlation (DVC) method, through comparing μCT images in different loading steps. To this end, dental implants were inserted into the cylindrical trabecular bones, then the bone-implant structure was undergone step-wise loading-unloading cycles, and μCT images were taken in some particular steps, then comparison was made between undeformed and deformed configurations using DVC to quantify plastic strain within the trabecular bone. Comparing stiffness reduction and dissipated energy values in different loading steps, obtained from the force-displacement curve in each loading step, revealed that the maximum displacement of 0.16 mm can be deemed as a safe threshold above which damages in peri-implant bone started to increase considerably (p < 0.05). In addition, it was found here that peri-implant bone strain linearly increased with decreasing bone-implant stiffness (p < 0.05). Moreover, strain concentration in peri-implant bone region showed that the plastic strain in trabecular bone spread up to a distance of about 2.5 mm away from the implant surface. Research of this kind can be used to optimize the design of dental implants, with the ultimate goal of improving their stability, also to validate in-silico models, e.g., micro-finite element models, which can help gain a deeper understanding of bone-implant construct behavior.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (64)

Show source-provided references
1. Digital volume correlation: three-dimensional strain mapping using X-ray tomography10.1007/BF02323555 ↗
2. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
3. Multiscale analyses of the bone-implant interface10.1177/0022034514566029 ↗
4. Esthetic outcomes following immediate and early implant placement in the anterior maxilla—a systematic review10.11607/jomi.2014suppl.g3.3 ↗
5. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
6. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants10.1016/j.jbiomech.2015.05.014 ↗
7. Immediate post-extraction implants subject to immediate loading: a meta-analytic study10.4317/medoral.16918 ↗
8. Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation10.1016/j.actbio.2021.06.014 ↗
9. Three-dimensional full-field measurements of large deformations in soft materials using confocal microscopy and digital volume correlation10.1007/s11340-007-9037-9 ↗
10. Stability measurements of one-stage Brånemark implants during healing in mandibles: a clinical resonance frequency analysis study10.1016/S0901-5027(99)80156-8 ↗
11. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
12. Elucidating failure mechanisms in human femurs during a fall to the side using bilateral digital image correlation10.1016/j.jbiomech.2020.109826 ↗
13. Effects of biomechanical properties of the bone–implant interface on dental implant stability: from in silico approaches to the patient's mouth10.1146/annurev-bioeng-071813-104854 ↗
14. Digital volume correlation for study of the mechanics of whole bones10.1016/j.piutam.2012.05.013 ↗
15. Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra10.1016/j.jbiomech.2013.04.004 ↗
16. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
17. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation10.1556/imas.5.2013.4.3 ↗
18. Evaluation of strain field in microstructures using micro-CT and digital volume correlation10.1088/1748-0221/6/01/C01039 ↗
19. Trabecular deformations during screw pull-out: a micro-CT study of lapine bone10.1007/s10237-017-0891-9 ↗
20. Mechanical behavior of damaged trabecular bone10.1016/0021-9290(94)90040-X ↗
21. Mechanical behavior of human trabecular bone after overloading10.1002/jor.1100170308 ↗
22. The application of digital volume correlation (DVC) to evaluate strain predictions generated by finite element models of the osteoarthritic humeral head10.1007/s10439-020-02549-2 ↗
23. Bone damage evolution around integrated metal screws using x-ray tomography—in situ pullout and digital volume correlation10.3389/fbioe.2020.00934 ↗
24. Bone damage evolution around integrated metal screws using x-ray tomography—in situ pullout and digital volume correlation10.3389/fbioe.2020.00934 ↗
25. Lemaitre · 2006
26. Effect of mechanical stimuli on skeletal regeneration around implants10.1016/j.bone.2006.10.027 ↗
27. An energy dissipation-based model for damage stimulated bone adaptation10.1016/S0021-9290(98)00039-6 ↗
28. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
29. Nonrigid image registration using conditional mutual information10.1109/TMI.2009.2021843 ↗
30. In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography10.1038/s41551-019-0477-1 ↗
31. Assessment of implant stability as a prognostic determinant
32. Continuum damage interactions between tension and compression in osteonal bone10.1016/j.jmbbm.2015.05.007 ↗
33. Micro-compression: a novel technique for the nondestructive assessment of local bone failure10.3233/THC-1998-65-616 ↗
34. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
35. Validation of finite element models of the mouse tibia using digital volume correlation10.1016/j.jmbbm.2018.06.022 ↗
36. A nonlinear homogenized finite element analysis of the primary stability of the bone–implant interface10.1007/s10237-018-1038-3 ↗
37. Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis10.1016/j.jmbbm.2019.06.024 ↗
38. Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
39. Digital volume correlation can be used to estimate local strains in natural and augmented vertebrae: an organ-level study10.1016/j.jbiomech.2016.10.018 ↗
40. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms10.1016/j.jbiomech.2017.04.007 ↗
41. Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems10.1111/jmi.12745 ↗
42. Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images10.1016/S8756-3282(02)00736-6 ↗
43. Fully experiment-based evaluation of few digital volume correlation techniques10.1063/1.5099572 ↗
44. Quesada García · 2009
45. Primary stability: the password of implant integration10.4103/0974-6781.102223 ↗
46. Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation10.1016/j.jmbbm.2019.04.054 ↗
47. Femoral fracture type can be predicted from femoral structure: a finite element study validated by digital volume correlation experiments10.1002/jor.23669 ↗
48. Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review10.1016/j.jbiomech.2014.01.001 ↗
49. Digital volume correlation including rotational degrees of freedom during minimization10.1007/BF02410982 ↗
50. Screw insertion in trabecular bone causes peri-implant bone damage10.1016/j.medengphy.2016.01.006 ↗
51. A novel in silico method to quantify primary stability of screws in trabecular bone10.1002/jor.23551 ↗
52. Considerations preliminary to the application of early and immediate loading protocols in dental implantology10.1034/j.1600-0501.2000.011001012.x ↗
53. In vivo deformation and strain measurements in human bone using digital volume correlation (DVC) and 3T clinical MRI10.3390/ma13235354 ↗
54. A two-step approach for transforming continuous variables to normal: implications and recommendations for IS research
55. Microdamage assessment of bone-cement interfaces under monotonic and cyclic compression10.1016/j.jbiomech.2014.09.012 ↗
56. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: local analysis on bone and cement-bone microstructures10.1016/j.jmbbm.2016.12.006 ↗
57. Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations10.1016/j.jbiomech.2008.02.032 ↗
58. Peroperative estimation of bone quality and primary dental implant stability10.1016/j.jmbbm.2018.12.035 ↗
59. Dependence of trabecular damage on mechanical strain10.1002/jor.1100150522 ↗
60. Damage accumulation in vertebral trabecular bone depends on loading mode and direction10.1016/j.jbiomech.2011.01.018 ↗
61. Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone10.1016/S0736-0266(01)00053-5 ↗
62. 3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors10.1016/j.jmbbm.2020.103858 ↗
63. Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure10.1016/j.jbiomech.2008.07.025 ↗
64. A 3D damage model for trabecular bone based on fabric tensors10.1016/S0021-9290(96)80006-6 ↗