Ceramic surface conditioning, resin cement viscosity, and aging relationships affect the load-bearing capacity under fatigue of bonded glass-ceramics
Source abstract
Abstract
This study aimed to evaluate the influence of ceramic surface treatments, resin cement viscosities, and storage regimens on the fatigue performance of bonded glass-ceramics (lithium disilicate, LD; feldspathic, FEL). Ceramic discs (Ø = 10 mm; thickness = 1.5 mm) were allocated into eight groups per ceramic (n = 15), considering three factors: "ceramic surface treatment" in two levels - 5% hydrofluoric acid etching and silane-based coupling agent application (HF), or self-etching ceramic primer (E&P); "resin cement viscosity" in two levels - in high or low viscosity; and "storage regimen" in two levels - baseline, 24 h to 5 days; or aging, 180 days + 25,000 thermal cycles. Adhesive luting was performed onto glass fiber-reinforced epoxy resin discs (Ø = 10 mm; thickness = 2 mm) and the bonded assemblies were subjected to cyclic fatigue tests: initial load = 200 N; step-size = 25 N (FEL) and 50 N (LD); 10,000 cycles/step; 20 Hz. Scanning electron microscopy (SEM) inspections were performed. Regarding the LD ceramic, the fatigue behavior was reduced after aging for HF_HIGH and E&P_LOW conditions, while stable performance was observed for HF_LOW and E&P_HIGH. Regarding the FEL results, aging negatively affected HF_HIGH, E&P_HIGH, and E&P_LOW, being that only the HF_LOW condition presented a stable behavior. The failure initiated from defects on the etched surface of the ceramics, where the cross-sectional analysis commonly revealed unfilled areas. Long-term aging might induce a decrease in mechanical behavior. The 'ceramic microstructure/surface conditioning/resin cement viscosity relationships' modulate the fatigue performance of lithium disilicate and feldspathic glass-ceramics.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Academy of Dental Materials guidance on in vitro testing of dental composite bonding effectiveness to dentin/enamel using micro-tensile bond strength (μTBS) approach10.1016/j.dental.2016.11.015 ↗
2. Fatigue failure and success rate of lithium disilicate table-tops as a function of cement thickness10.2186/jpr.JPR_D_20_00220 ↗
3. Influence of inorganic filler content of resin luting agents and use of adhesive on the performance of bonded ceramic10.1016/j.prosdent.2019.09.013 ↗
4. Effect of finishing and polishing on the surface roughness and gloss of feldspathic ceramic for chairside CAD/CAM systems10.2341/15-174-L ↗
5. The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses10.1016/j.dental.2014.05.018 ↗
6. Does adhesive luting promote improved fatigue performance of lithium disilicate simplified crowns?10.1016/j.jmbbm.2022.105373 ↗
7. Weak adhesion between ceramic and resin cement impairs the load-bearing capacity under fatigue of lithium disilicate glass-ceramic crowns
8. One-step ceramic primer as surface conditioner: effect on the load-bearing capacity under fatigue of bonded lithium disilicate ceramic simplified restorations10.1016/j.jmbbm.2020.103686 ↗
9. Do resin cement viscosity and ceramic surface etching influence the fatigue performance of bonded lithium disilicate glass-ceramic crowns?10.1016/j.dental.2021.12.015 ↗
10. Silane reactivity and resin bond strength to lithium disilicate ceramic surfaces10.1016/j.dental.2019.05.002 ↗
11. Self-etching ceramic primer versus hydrofluoric acid etching: etching efficacy and bonding performance10.1016/j.jpor.2017.06.002 ↗
12. Impact of machining on the flexural fatigue strength of glass and polycrystalline CAD/CAM ceramics10.1016/j.dental.2017.07.019 ↗
13. Influence of the resin cement thickness on the fatigue failure loads of CAD/CAM feldspathic crowns10.1016/j.dental.2015.04.019 ↗
14. Recent advances in materials for all-ceramic restorations10.1016/j.cden.2007.04.006 ↗
15. Effect of microstructure on the mechanical properties of lithium disilicate glass-ceramics10.1016/j.jmbbm.2018.02.032 ↗
16. Ceramic materials in dentistry: historical evolution and current practice10.1111/j.1834-7819.2010.01299.x ↗
17. ADM guidance-ceramics: fatigue principles and testing10.1016/j.dental.2017.09.006 ↗
18. Development of a clinically validated bulk failure test for ceramic crowns10.1016/S0022-3913(10)60129-1 ↗
19. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
20. Effects of thermal and mechanical cycling on the mechanical strength and surface properties of dental CAD-CAM restorative materials
21. Reduction of load-bearing capacity of all-ceramic crowns due to cement aging10.1016/j.jmbbm.2012.08.003 ↗
22. Cements and adhesives for all-ceramic restorations10.1016/j.cden.2011.01.011 ↗
23. Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing10.1016/j.dental.2012.04.033 ↗
24. Effect of milling, fitting adjustments, and hydrofluoric acid etching on the strength and roughness of CAD-CAM glass-ceramics: a systematic review and meta-analysis
25. Survival and complications of monolithic ceramic for tooth-supported fixed dental prostheses: a systematic review and meta-analysis10.1016/j.prosdent.2021.01.020 ↗
26. Fatigue failure load of zirconia-reinforced lithium silicate glass ceramic cemented to a dentin analogue: Effect of etching time and hydrofluoric acid concentration10.1016/j.jmbbm.2017.09.028 ↗
27. Measurement of masticatory forces and implant loads: a methodologic clinical study
28. Two-Year follow-up of self-etching ceramic primer as surface treatment for feldspathic veneers: a clinical case review10.2341/20-036-T ↗
29. Surface/interface morphology and bond strength to glass ceramic etched for different periods10.2341/09-152-L ↗
30. Influence of accelerated ageing on the physical properties of CAD/CAM restorative materials10.1007/s00784-019-03101-w ↗
31. In-lab simulation of CAD/CAM milling of lithium disilicate glass-ceramic specimens: effect on the fatigue behavior of the bonded ceramic10.1016/j.jmbbm.2021.104604 ↗
32. Ceramic surface treatment with a single-component primer: resin adhesion to glass ceramics
33. How does hydrofluoric acid etching affect the cyclic load-to-failure of lithium disilicate restorations?10.1016/j.jmbbm.2018.07.040 ↗
34. Adhesion to a lithium disilicate glass ceramic etched with hydrofluoric acid at distinct concentrations10.1590/0103-6440201802080 ↗
35. Hydrofluoric acid concentrations: Effect on the cyclic load-to-failure of machined lithium disilicate restorations10.1016/j.dental.2018.06.028 ↗
36. Internal adjustments decrease the fatigue failure load of bonded simplified lithium disilicate restorations10.1016/j.dental.2018.05.015 ↗
37. Fracture resistance of lithium disilicate ceramics bonded to enamel or dentin using different resin cement types and film thicknesses10.1111/jopr.12372 ↗
38. Effects of surface treatments on the bond strength between resin cement and a new zirconia-reinforced lithium silicate ceramic10.2341/14-357-L ↗
39. Fatigue failure load of an adhesively-cemented lithium disilicate glass-ceramic: conventional ceramic etching vs etch & prime one-step primer10.1016/j.dental.2018.04.012 ↗
40. CAD-CAM milled versus pressed lithium-disilicate monolithic crowns adhesively cemented after distinct surface treatments: fatigue performance and ceramic surface characteristics10.1016/j.jmbbm.2019.03.005 ↗
41. Effect of water storage time and composite cement thickness on fatigue of a glass-ceramic trilayer system10.1002/jbm.b.30851 ↗
42. Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study10.1186/s12903-017-0458-2 ↗
43. Two-year follow-up of ceramic veneers and a Full crown treated with self-etching ceramic primer: a case report10.2341/19-090-R ↗
44. Ceramic strengthening by tuning the elastic moduli of resin-based luting agents10.1016/j.dental.2017.01.002 ↗
45. Strengthening of porcelain provided by resin cements and flowable composites10.2341/15-025-L ↗
46. CAD/CAM ceramic restorative materials for natural teeth10.1177/0022034518779759 ↗
47. Aspects of bonding between resin luting cements and glass ceramic materials10.1016/j.dental.2014.01.017 ↗
48. Influence of ceramic material, thickness of restoration and cement layer on stress distribution of occlusal veneers10.1590/1807-3107bor-2018.vol32.0118 ↗
49. Effect of cement layer thickness on the immediate and long-term bond strength and residual stress between lithium disilicate glass-ceramic and human dentin10.3390/ma14185153 ↗
50. Elastic properties of lithium disilicate versus feldspathic inlays: effect on the bonding by 3D finite element analysis10.1111/jopr.12550 ↗
51. A brief review on fatigue test of ceramic and some related matters in Dentistry10.1016/j.jmbbm.2022.105607 ↗
52. Editorial: the VALUE and remaining NEED of bond-strength testing
53. Accelerated loading frequency does not influence the fatigue behavior of polymer infiltrated ceramic network or lithium disilicate glass-ceramic restorations10.1016/j.jmbbm.2020.103905 ↗
54. Cyclic fatigue tests on non-anatomic specimens of dental ceramic materials: a scoping review10.1016/j.jmbbm.2021.104985 ↗
55. Fatigue performance of adhesively cemented glass-, hybrid- and resin-ceramic materials for CAD/CAM monolithic restorations10.1016/j.dental.2019.01.013 ↗
56. The effect of hydrofluoric acid concentration on the fatigue failure load of adhesively cemented feldspathic ceramic discs10.1016/j.dental.2018.01.010 ↗
57. Effect of hydrofluoric acid concentration on resin adhesion to a feldspathic ceramic
58. Effect of resin cement space on the fatigue behavior of bonded CAD/CAM leucite ceramic crowns10.1016/j.jmbbm.2020.103893 ↗
59. Dental ceramics for restoration and metal veneering10.1016/j.cden.2017.06.005 ↗