A reliable and replicable test protocol for the mechanical evaluation of synthetic meshes
Source abstract
Abstract
Despite the worldwide spread of surgical meshes in abdominal and inguinal surgery repair, the lack of specific standards for mechanical characterization of synthetic meshes, used in hernia repair and urogynecologic surgery, makes performance comparison between prostheses undoubtedly difficult. This consequently leads to the absence of acknowledged specifications about the mechanical requirements that synthetic meshes should achieve in order to avoid patient discomfort or hernia recurrences. The aim of this study is to provide a rigorous test protocol for the mechanical comparison between surgical meshes having the same intended use. The test protocol is composed of three quasi-static test methods: (1) ball burst test, (2) uniaxial tensile test, and (3) suture retention test. For each test, post-processing procedures are proposed to compute relevant mechanical parameters from the raw data. Some of the computed parameters, indeed, could be more suitable for comparison with physiological conditions (e.g., membrane strain and anisotropy), while others (e.g., uniaxial tension at rupture and suture retention strength) are reported as they provide useful mechanical information and could be convenient for comparisons between devices. The proposed test protocol was applied on 14 polypropylene meshes, 3 composite meshes, and 6 urogynecologic devices to verify its universal applicability towards meshes of different types and produced by various manufacturers, and its repeatability in terms of coefficient of variation. The test protocol resulted easily applicable to all the tested surgical meshes with intra-subject variability characterized by coefficient of variations settled around 0.05. Its use within other laboratories could allow the determination of the inter-subject variability assessing its repeatability among users of alternative universal testing machines.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Hernia repair and management · Pelvic and Acetabular Injuries · Abdominal Surgery and Complications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Biomechanical compatibility of surgical mesh and fascia being reinforced: dependence of experimental hernia defect repair results on anisotropic surgical mesh positioning10.1007/s10029-011-0877-y ↗
2. The search for ideal hernia repair; mesh materials and types10.1016/j.ijsu.2012.05.002 ↗
3. Normal intraabdominal pressure in healthy adults10.1016/j.jss.2005.06.015 ↗
4. The argument for lightweight polypropylene mesh in hernia repair10.1177/155335060501200109 ↗
5. Classification of prosthetics used in hernia repair based on weight and biomaterial10.1007/s10029-011-0868-z ↗
6. Cordero · 2015
7. Biomechanical, topological and chemical features that influence the implant success of an urogynecological mesh: a review10.1155/2016/1267521 ↗
8. Physicomechanical evaluation of absorbable and nonabsorbable barrier composite meshes for laparoscopic ventral hernia repair10.1007/s00464-010-1432-0 ↗
9. Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair10.1016/j.jamcollsurg.2010.09.012 ↗
10. Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair10.1016/j.jmbbm.2017.05.008 ↗
11. Biaxial analysis of synthetic scaffolds for hernia repair demonstrates variability in mechanical anisotropy , non-linearity and hysteresis10.1016/j.jmbbm.2014.06.001 ↗
12. Mechanical properties of urogynecologic implant materials10.1007/s00192-003-1041-8 ↗
13. Effect of repetitive loading on the mechanical properties of synthetic hernia repair materials10.1016/j.jamcollsurg.2011.05.018 ↗
14. Multi-directional mechanical analysis of synthetic scaffolds for hernia repair10.1016/j.jmbbm.2017.02.009 ↗
15. Analytically derived material properties of multilaminated extracellular matrix devices using the ball-burst test10.1016/j.biomaterials.2005.01.070 ↗
16. Acta Biomaterialia Mechanical behaviour of synthetic surgical meshes
17. Biomechanical properties of lightweight versus heavyweight meshes for laparoscopic inguinal hernia repair and their impact on recurrence rates10.1007/s00464-008-9936-6 ↗
18. Tensile properties of commonly used prolapse meshes10.1007/s00192-008-0781-x ↗
19. Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants10.1007/s100290100019 ↗
20. Design strategies and applications of biomaterials and devices for Hernia repair
21. [Pathophysiology of the abdominal wall]
22. Modified classiffication of surgical meshes for hernia repair based on the analyses of 1,000 explanted meshes10.1007/s10029-012-0913-6 ↗
23. The lightweight and large porous mesh concept for hernia repair10.1586/17434440.2.1.103 ↗
24. Polymers in hernia repair - common polyester vs. polypropylene surgical meshes10.1023/A:1004812410141 ↗
25. Maximum forces acting on the abdominal wall: experimental validation of a theoretical modeling in a human cadaver study10.1016/j.medengphy.2011.01.010 ↗
26. Biomechanical evaluation of potential damage to hernia repair materials due to fixation with helical titanium tacks10.1007/s00464-011-1816-9 ↗
27. Characterizing the ex vivo mechanical properties of synthetic polypropylene surgical mesh10.1016/j.jmbbm.2014.05.005 ↗
28. Are biomechanical properties predictive of the success of prostheses used in stress urinary incontinence and pelvic organ prolapse? A systematic review10.1002/nau.21156 ↗
29. Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications10.1016/j.jss.2013.03.044 ↗
30. Prosthetic meshes for repair of hernia and pelvic organ prolapse: comparison of biomechanical properties10.3390/ma8052794 ↗
31. Mechanical biocompatibility of prosthetic meshes: a comprehensive protocol for mechanical characterization10.1016/j.jmbbm.2014.08.005 ↗
32. Physical characteristics of medical textile prostheses designed for hernia repair: a comprehensive analysis of select commercial devices10.3390/ma8125453 ↗
33. Tensile properties of five commonly used mid-urethral slings relative to the TVTTM10.1007/s00192-007-0499-1 ↗
34. Calculation of membrane tension in selected sections of the pelvic floor10.1007/s00192-013-2253-1 ↗
35. Mechanical properties of mesh materials used for hernia repair and soft tissue augmentation10.1371/journal.pone.0046978 ↗
36. Surgical mesh for ventral incisional hernia repairs: understanding mesh design10.1177/229255031602400110 ↗
37. Biomechanical properties of the pelvic Floor and its relation to pelvic Floor disorders10.1016/j.eursup.2017.12.002 ↗
38. Anisotropic evaluation of synthetic surgical meshes10.1007/s10029-010-0731-7 ↗
39. Clinically relevant mechanical testing of hernia graft constructs10.1016/j.jmbbm.2014.10.011 ↗
40. Uniaxial biomechanical properties of seven different vaginally implanted meshes for pelvic organ prolapse10.1007/s00192-011-1616-8 ↗
41. In vivo characterization of a fluoropassivated gelatin-impregnated polyester mesh for hernia repair10.1002/(SICI)1097-4636(199611)32:3<293::AID-JBM2>3.0.CO;2-N ↗
42. Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery10.1007/s00464-005-0676-6 ↗
43. Investigation of the mechanical behavior of polyester meshes for abdominal surgery: a preliminary study10.1007/s40846-017-0337-y ↗
44. Synthetic surgical meshes used in abdominal wall surgery: Part II—biomechanical aspects10.1002/jbm.b.33584 ↗
45. Evaluation of dynamic creep properties of surgical mesh prostheses - uniaxial fatigue10.1002/jbm.b.31401 ↗
46. Force measurement in the abdominal wall
47. Wolf
48. Inguinal hernia: measurement of the biomechanics of the lower abdominal wall and the inguinal canal10.1007/s10029-004-0224-7 ↗
49. Mesh implants: an overview of crucial mesh parameters10.4240/wjgs.v7.i10.226 ↗