Effect of corneal collagen crosslinking on viscoelastic shear properties of the cornea
Source abstract
Abstract
The cornea is responsible for most of the refractive power in the eye and acts as a protective layer for internal contents of the eye. The cornea requires mechanical strength for maintaining its precise shape and for withstanding external and internal forces. Corneal collagen crosslinking (CXL) is a treatment option to improve corneal mechanical properties. The primary objective of this study was to characterize CXL effects on viscoelastic shear properties of the porcine cornea as a function of compressive strain. For this purpose, corneal buttons were prepared and divided into three groups: control group (n = 5), pseudo-crosslinked group (n = 5), and crosslinked group (n = 5). A rheometer was used to perform dynamics torsional shear experiments on corneal disks at different levels of compressive strain (0%-40%). Specifically, strain sweep experiments and frequency sweep tests were done in order to determine the range of linear viscoelasticity and frequency dependent shear properties, respectively. It was found that the shear properties of all samples were dependent on the shear strain magnitude, loading frequency, and compressive strain. With increasing the applied shear strain, all samples showed a nonlinear viscoelastic response. Furthermore, the shear modulus of samples increased with increasing the frequency of the applied shear strain and/or increasing the compressive strain. Finally, the CXL treatment significantly increased the shear storage and loss moduli when the compressive strain was varied from 0% to 30% (p < 0.05); larger shear moduli were observed at compressive 40% strain but the difference was not significant (P = 0.12).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corneal surgery and disorders · Corneal Surgery and Treatments · Ocular Surface and Contact Lens
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Brain tissue mechanical properties
2. Boschetti · 2012
3. Stress-controlled viscoelastic tensile response of bovine cornea10.1016/j.jbiomech.2006.12.001 ↗
4. Bryant · 1996
5. The relationship between mechanical properties, ultrastructural changes, and intrafibrillar bond formation in corneal UVA/riboflavin cross-linking treatment for keratoconus10.3928/1081597X-20180220-01 ↗
6. Comparative study of corneal strip extensometry and inflation tests10.1098/rsif.2005.0034 ↗
7. Linear shear response of the upper skin layers
8. Optical coherence elastography assessment of corneal viscoelasticity with a modified Rayleigh-Lamb wave model10.1016/j.jmbbm.2016.11.004 ↗
9. The molecular basis of corneal transparency10.1016/j.exer.2010.06.021 ↗
10. Viscoelastic shear properties of the corneal stroma10.1016/j.jbiomech.2013.11.019 ↗
11. Influence of microstructure on stiffening effects of corneal cross-linking treatment10.3928/1081597X-20180718-01 ↗
12. Hydration dependent biomechanical properties of the corneal stroma10.1016/j.exer.2013.07.016 ↗
13. A new method to determine rate-dependent material parameters of corneal extracellular matrix10.1007/s10439-013-0842-2 ↗
14. UVA/riboflavin collagen crosslinking stiffening effects on anterior and posterior corneal flaps10.1016/j.exer.2018.05.014 ↗
15. Relationship between initial corneal hydration and stiffening effects of corneal crosslinking treatment10.1016/j.jcrs.2018.01.036 ↗
16. A biphasic transversely isotropic poroviscoelastic model for the unconfined compression of hydrated soft tissue10.1115/1.4032059 ↗
17. The relation between hydration and mechanical behavior of bovine cornea in tension10.1016/j.jmbbm.2014.03.011 ↗
18. Evaluation of hydration effects on tensile properties of bovine corneas10.1016/j.jcrs.2014.07.029 ↗
19. Collagen cross-linking treatment effects on corneal dynamic biomechanical properties10.1016/j.exer.2015.04.005 ↗
20. Swelling pressure and hydration behavior of porcine corneal stroma10.3109/02713683.2013.809769 ↗
21. Flow-independent viscoelastic properties of articular cartilage matrix10.1016/0021-9290(78)90075-1 ↗
22. The effect of riboflavin/UVA collagen cross-linking therapy on the structure and hydrodynamic behaviour of the ungulate and rabbit corneal stroma10.1371/journal.pone.0052860 ↗
23. Depth- and direction-dependent changes in solute transport following cross-linking with riboflavin and UVA light in ex vivo porcine cornea10.1016/j.exer.2021.108498 ↗
24. Hoeltzel · 1992
25. A 48-year clinical and epidemiologic study of keratoconus10.1016/0002-9394(86)90817-2 ↗
26. In vivo human corneal shear-wave optical coherence elastography10.1097/OPX.0000000000001633 ↗
27. Biomechanical property analysis after corneal collagen cross-linking in relation to ultraviolet A irradiation time10.1007/s00417-011-1674-0 ↗
28. Structural interactions between collagen and proteoglycans are elucidated by three-dimensional electron tomography of bovine cornea10.1016/j.str.2009.11.013 ↗
29. Effect of eye-rubbing and breath-holding on corneal biomechanical properties and intraocular pressure
30. The structure and transparency of the cornea10.1113/jphysiol.1957.sp005758 ↗
31. Mechanisms of corneal tissue cross-linking in response to treatment with topical riboflavin and long-wavelength ultraviolet radiation (UVA)10.1167/iovs.09-3738 ↗
32. Mechanisms of rubbing-related corneal trauma in keratoconus10.1097/ICO.0b013e318198384f ↗
33. The cornea and sclera
34. Viscoelastic and equilibrium shear properties of human meniscus: relationships with tissue structure and composition10.1016/j.jbiomech.2021.110343 ↗
35. Depth-dependent transverse shear properties of the human corneal stroma10.1167/iovs.11-8611 ↗
36. Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE10.1038/s41598-020-69909-9 ↗
37. In vivo measurement of shear modulus of the human cornea using optical coherence elastography10.1038/s41598-020-74383-4 ↗
38. Optimization model for UV-riboflavin corneal cross-linking10.1167/iovs.11-8059 ↗
39. A comparative biochemical and ultrastructural study of proteoglycan-collagen interactions in corneal stroma. Functional and metabolic implications10.1042/bj2700491 ↗
40. Pathogenesis of Keratoconus: the intriguing therapeutic potential of Prolactin-inducible protein10.1016/j.preteyeres.2018.05.002 ↗
41. The location- and depth-dependent mechanical response of the human cornea under shear loading10.1167/iovs.14-14997 ↗
42. Corneal resistance to shear force after UVA-riboflavin cross-linking10.1167/iovs.12-10710 ↗
43. Induction of cross-links in corneal tissue10.1006/exer.1997.0410 ↗
44. Long-term biomechanical properties of rabbit cornea after photodynamic collagen crosslinking10.1111/j.1755-3768.2008.01190.x ↗
45. Stress-strain measurements of human and porcine corneas after riboflavin–ultraviolet-A-induced cross-linking10.1016/S0886-3350(03)00407-3 ↗
46. Riboflavin/ultraviolet-a–induced collagen crosslinking for the treatment of keratoconus10.1016/S0002-9394(02)02220-1 ↗
47. A comparison of biomechanical properties between human and porcine cornea10.1016/S0021-9290(00)00219-0 ↗
48. Effects of ultraviolet-A and riboflavin on the interaction of collagen and proteoglycans during corneal cross-linking10.1074/jbc.M110.169813 ↗
49. Viscoelastic shear properties of articular cartilage and the effects of glycosidase treatments10.1002/jor.1100110602 ↗