journal article·2021-06

Characterization of the dynamic viscoelastic response of the ascending aorta imposed via pulsatile flow

S. Pejcic, M.R. Najjari, G. Bisleri, D.E. Rival

Publisher page

Abstract

This study characterizes the material properties of a viscoelastic, ex vivo porcine ascending aorta under dynamic-loading conditions via pulsatile flow. The deformation of the opaque vessel wall and the pulsatile flow field inside the vessel were recorded using ultrasound imaging. The internal pressure was extracted from the pulsatile flow results and, when coupled with the vessel-wall expansion, was used to calculate the instantaneous elastic modulus from a novel, time-resolved two-dimensional (i.e. axial and circumferential) stress model. The circumferential instantaneous elasticity obtained from the two-dimensional stress model was found to match the uniaxial tensile test for strains below 50%. The agreement in elasticity between the two stress states reveals that the two-dimensional stress model accurately resolves the circumferential stress of the viscoelastic aorta at physiological strains (8%-30%). At higher strains, results from pulsatile flow generated a more compliant response than the uniaxial measurements. Viscoelastic properties (storage modulus and loss factor) were also calculated using the two-dimensional stress model and compared to those obtained from uniaxial tests. While instantaneous elasticity matched between the cylindrical and uniaxial loading, the viscoelastic behaviour significantly diverged between stress states. The storage modulus obtained from the pulsatile flow data was dependent on mean Reynolds number, while the uniaxial storage modulus results exhibited a strong inverse dependency on the frequency. The loss factor for the pulsatile flow data increased alongside the frequency, while the uniaxial data indicated a constant loss factor over the entire frequency range. The results of the current study show that the two-dimensional stress model can accurately extract the material properties of the ex vivo porcine aorta.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Elasticity and Material Modeling · Cardiac Valve Diseases and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Characterizing the elastic properties of tissues10.1016/S1369-7021(11)70059-1 ↗
2. Layer-specific hyperelastic and viscoelastic characterization of human descending thoracic aortas10.1016/j.jmbbm.2019.07.008 ↗
3. Anisotropic fractional viscoelastic constitutive models for human descending thoracic aortas10.1016/j.jmbbm.2019.07.010 ↗
4. Nonlinear dynamics of human aortas for material characterization
5. Biomechanical evaluation of ascending aortic aneurysms10.1155/2014/820385 ↗
6. The dynamic elastic properties of the arterial wall10.1113/jphysiol.1961.sp006687 ↗
7. The static elastic properties of the arterial wall10.1113/jphysiol.1961.sp006686 ↗
8. Regional differences in viscosity, elasticity, and wall buffering function in systemic arteries: pulse wave analysis of the arterial pressure-diameter relationship10.1157/13071891 ↗
9. Fluid-solid interaction simulation of flow and stress pattern in thoracoabdominal aneurysms: a patient-specific study10.1016/j.jfluidstructs.2007.08.005 ↗
10. Arterial extracellular matrix: a mechanobiological study of the contributions and interactions of elastin and collagen10.1016/j.bpj.2014.05.014 ↗
11. Transmural organization of the arterial media: the lamellar unit revisited10.1161/01.ATV.5.1.19 ↗
12. Identifying hyper-viscoelastic model parameters from an inflation-extension test and ultrasound images10.1007/s11340-015-0042-0 ↗
13. Biaxial rupture properties of ascending thoracic aortic aneurysms10.1016/j.actbio.2016.06.028 ↗
14. Human dilated ascending aorta: mechanical characterization via uniaxial tensile tests10.1016/j.jmbbm.2015.08.021 ↗
15. Fung · 1993
16. Fung · 1996
17. Haddad · 1995
18. Mechanics, mechanobiology, and modeling of human abdominal aorta and aneurysms10.1016/j.jbiomech.2011.11.021 ↗
19. In vivo viscoelastic behavior in the human aorta10.1161/01.RES.66.5.1413 ↗
20. Biaxial mechanical properties of the human thoracic and abdominal aorta, common carotid, subclavian, renal and common iliac arteries10.1007/s10237-014-0576-6 ↗
21. Determination of the elastic modulus of ascending thoracic aortic aneurysm at different ranges of pressure using uniaxial tensile testing10.1016/j.jtcvs.2010.09.068 ↗
22. Elastic properties of the young aorta: ex vivo perfusion experiments in a porcine model10.1093/ejcts/ezu438 ↗
23. Lakes · 2009
24. Aortic aneurysm10.1515/jtim-2016-0008 ↗
25. Oscillatory motions of a prestrained compliant membrane caused by fluid-membrane interaction10.1016/j.jfluidstructs.2009.11.003 ↗
26. Microstructure and mechanics of healthy and aneurysmatic abdominal aortas: experimental analysis and modelling10.1098/rsif.2016.0620 ↗
27. Arterial stiffness and hypertension10.1186/s40885-018-0102-8 ↗
28. An ultrasound based approach for the characterization of fluid – structure interaction of large arterial vessels
29. Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta10.1016/j.jmbbm.2015.05.024 ↗
30. Poisson's contraction and fiber kinematics in tissue: insight from collagen network simulations10.1115/1.4038428 ↗
31. Ultrasound imaging velocimetry: a review10.1007/s00348-016-2283-9 ↗
32. Investigation of the optimal collagen fibre orientation of human iliac arteries10.1016/j.jmbbm.2015.06.011 ↗
33. Ultrasonic measurement of the elastic modulus of the common carotid artery: the atherosclerosis risk in communities (aric) study10.1161/01.STR.23.7.952 ↗
34. Pulse-wave propagation in straight-geometry vessels for stiffness estimation: theory, simulations, phantoms and in vitro findings10.1115/1.4007747 ↗
35. A structural basis for the aortic stress-strain relation in uniaxial tension10.1016/j.jbiomech.2005.05.003 ↗
36. Turbulent blood flow in the ascending aorta of humans with normal and diseased aortic valves10.1161/01.RES.39.1.58 ↗
37. Linear and nonlinear viscoelastic modeling of aorta and carotid pressure-area dynamics under in vivo and ex vivo conditions10.1007/s10439-010-0236-7 ↗
38. PIV-based pressure measurement10.1088/0957-0233/24/3/032001 ↗
39. Hyperelastic behavior of porcine aorta segment under extension-inflation tests fitted with various phenomenological models
40. Elastin in large artery stiffness and hypertension10.1007/s12265-012-9349-8 ↗
41. Radial and longitudinal motion of the arterial wall: their relation to pulsatile pressure and flow in the artery
42. Evolving mechanical properties of a model of abdominal aortic aneurysm10.1007/s10237-007-0115-9 ↗
43. Structural basis for the static mechanical properties of the aortic media10.1161/01.RES.14.5.400 ↗