An analytical model to measure dental implant stability with the Advanced System for Implant Stability Testing (ASIST)
Source abstract
Abstract
A non-invasive method of quantitatively assessing dental implant stability is important to monitor its long-term health. The Advanced System for Implant Stability Testing (ASIST) is a noninvasive technique that couples the impact technique with a linear vibration model of the implant system, such that the measured signal can be used to determine a matching analytical response. The purpose of this study was to evaluate the ASIST technique by comparing stability estimates obtained from artificial implant installations with various abutments. Two Straumann dental implants were installed in four densities of uniform polyurethane foam, and the stability of each installation was measured using different healing abutments and artificial dental crowns. With the ASIST, values for the estimated interfacial stiffness increased with foam density and did not significantly change with abutment type for a specific sample. This provides evidence that the analytical model is representative of the physical system. Current methods, such as resonance frequency analysis, interpret the interface stiffness based on a single frequency measurement. With the ASIST, the measured signal provides information about the first and second modes of vibration of the implant system, both of which are influenced by the properties of the corresponding abutment. The consideration of both modes allows the technique to reliably measure the interfacial stiffness independently of the system components. As a result, the ASIST technique may provide an improved non-invasive method of measuring the stability of dental implants.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. 2021
2. Methods used to assess implant stability: current status
3. Brånemark · 1985
4. Application of a vibration measuring technique to evlauate the dynamic stiffness of porcine periodontal ligament10.3233/THC-2006-144-526 ↗
5. A mathematical approach to estimate micro-displacement of a dental implant using electromagnetic frequency response analysis10.1016/j.jmbbm.2023.105735 ↗
6. Impact of timing of dental implant placement and loading: summary and consensus statements of Group 1 - the 6th EAO Consensus Conference 202110.1111/clr.13809 ↗
7. Influence of the implant abutment on the periotest value: an in vivo study
8. Gupta · 2022
9. Retrospective clinical study of tooth-supported single crowns: a multifactor analysis10.1111/eos.12871 ↗
10. Simulation of impact test for determining “health” of percutaneous bone anchored implants10.1115/1.2241685 ↗
11. New multi-layered zirconias: composition, microstructure and translucency10.1016/j.dental.2019.02.017 ↗
12. The reliability of Anycheck device related to healing abutment diameter10.4047/jap.2020.12.2.83 ↗
13. Periotest - a dynamic procedure for the diagnosis of the human periodontium10.1088/0143-0815/11/1/006 ↗
14. Characteristics of early versus late implant failure: a retrospective study10.1016/j.joms.2009.07.050 ↗
15. Resonance frequency measurements of implant stability in vivo10.1034/j.1600-0501.1997.080309.x ↗
16. Validation of an implant stability measurmenet device using the percussion response: a clinical research study10.1186/s12903-022-02320-0 ↗
17. Infectious risks for oral implants: a review of the literature10.1034/j.1600-0501.2002.130101.x ↗
18. Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface10.1186/s12938-019-0733-3 ↗
19. Potential damage to bone-implant interface when measuring initial implant stability10.1902/jop.2009.090169 ↗
20. Survival of single immediate implants and reasons for loss: a systematic review10.3390/prosthesis5020028 ↗
21. Potential risk factors for early and late dental implant failure: a retrospective clinical study on 9080 implants10.1186/s40729-020-00276-w ↗
22. Straumann · 2017
23. A dynamic analytical model for impact evaluation of percutaneous implants10.1115/1.2970061 ↗
24. An improved impact technique for monitoring percutaneous implant integrity
25. An in vitro evaluation on polyurethane foam sheets of the insertion torque, removal torque values, and resonance frequency analysis (RFA) of a self-tapping threads and round apex implant10.1177/0262489320971796 ↗
26. Use of patient-specific finite element models in dental rehabilitation to investigate stresses of a fibula free flap for mandibular reconstruction10.11607/jomi.6608 ↗
27. Identifiable range of osseointegration of dental implants through resonance frequency analysis10.1016/j.medengphy.2010.07.015 ↗
28. Advanced system for implant stability testing (ASIST)10.1016/j.jbiomech.2016.09.043 ↗
29. Longitudinal evaluation of bone-anchored hearing aid implant stability using the Advanced System for Implant Stability Testing (ASIST)10.1097/MAO.0000000000001815 ↗
30. Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis
31. The survival rates and risk factors of implants in the early stage: a retrospective study10.1186/s12903-021-01651-8 ↗
32. Modal analysis for implant stability assessment: sensitivity of this methodology for different implant designs10.1016/j.dental.2018.05.016 ↗
33. A noncontact detection technique for interfacial bone defects and osseointegration assessment surrounding dental implants10.1016/j.measurement.2014.05.039 ↗