journal article·2024-02

Retention loss and wear assessment of three attachment systems for implant retained-mandibular overdentures: An in vitro study

Raphaël Wakam, Srilakshmi Ramalingam, Kwamivi Bernardin Mawussi, Caroline Gorin, Aurélie Benoit

Publisher page

Abstract

Background The stud-shaped attachment systems (AS) with different shape designs (ball, cylindrical, conical) and materials (metallic, plastic, or a combination of both) are commonly used to provide better retention and stability in implant-retained mandibular overdentures (IRMO). Purpose The purpose of the present study was to evaluate and compare the retention loss and the wear (patterns, location, material loss) of three resilient unsplinted AS: a well-established ball attachment system (BAS) and two more recent cylindrical attachment systems (CAS), Locator R-Tx® and Novaloc®. Materials and methods The implants, their corresponding abutments, the color-coded or position-coded retention devices (RD), the matrix metal housing were incorporated within CAD/CAM resin blocks and cyclically loaded with 19.6 N along the implant axis in a chewing machine to simulate 10,000 insertion-removal cycles (IRC). At cycle 10, 100, 1,000, 5,000, and 10,000, the retention force was measured using a universal testing machine. The wear was qualitatively examined using a binocular magnifier for both systems, and quantitatively assessed from micro-computed tomography acquisitions for CAS. Material loss exceeding 50 μm was considered significant. Results The three AS showed different retentive behavior along time. All the Locator R-Tx® RD lost more than 50 % of their retention after 10,000 IRC. The retention of the Ball System slightly varied over time, the final retention loss in Bmed and Bmax groups being lower than 25 % of the initial retention. Wear was located at the tip of their gold RD and at the equator area of their ball abutment. For Locator R-Tx®, the more retentive the plastic RD, the greater its wear and retention loss. Only Novaloc® maintained a stable retention with even a slight tendency to increase and showed a negligible wear. Implant abutments of the CAS showed no significant wear. Conclusion After 10,000 IRC, corresponding to approximately 5-years clinical use, almost all RD provided retention force over 5 N, which could be sufficient to maintain satisfaction in most of the patients. The retention loss observed most prominently for the Locator R-Tx®, then for the Ball System, seemed to correlate with the wear observed on their RD. The practitioner may expect less RD maintenance with the Novaloc® stable retention overtime.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Temporomandibular Joint Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Retention of different attachment systems for digitally designed mandibular implant overdenture10.1111/jopr.13516 ↗
2. Effect of simulated masticatory loading on the retention of stud attachments for implant overdentures10.1111/j.1365-2842.2010.02145.x ↗
3. The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system10.1016/S0022-3913(09)60134-7 ↗
4. Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs
5. Mandibular single-implant overdentures: preliminary esults of a randomised-control trial on early loading with different implant diameters and attachment systems10.1111/j.1600-0501.2010.02004.x ↗
6. Retentive characteristics of a new attachment system for hybrid dentures10.3390/ma13153434 ↗
7. Resistance to wear of four matrices with ball attachments for implant overdentures: a fatigue study10.1111/j.1532-849X.2010.00613.x ↗
8. Prospective clinical evaluation of mandibular implant overdentures: Part I–Retention, stability, and tissue response10.1016/S0022-3913(05)80331-2 ↗
9. Retentive properties of two stud attachments with polyetherketoneketone or nylon insert in mandibular implant overdentures10.11607/jomi.6023 ↗
10. Five-year clinical trial using three attachment systems for implant overdentures10.1111/clr.12086 ↗
11. Single-implant overdentures retained by the Novaloc attachment system: study protocol for a mixed-methods randomized cross-over trial10.1186/s13063-018-2606-7 ↗
12. The McGill consensus statement on overdenture. Mandibular two-implant overdentures as first choice standard of care for edentulous patients
13. In vitro measurement of the retention force of two stud attachment systems during cyclic load
14. Clinical wear of overdenture ball attachments after 1, 3 and 8 years10.1111/j.1600-0501.2010.02102.x ↗
15. Effect of implant angulation on attachment retention in mandibular two-implant overdentures: a clinical study10.1111/cid.12030 ↗
16. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report10.1111/j.1708-8208.2009.00154.x ↗
17. Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems10.1111/clr.12156 ↗
18. Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial
19. Mandibular two-implant overdentures: prosthodontic maintenance using different loading protocols and attachment systems
20. In vitro retention force changes during cyclic dislodging of three novel attachment systems for implant overdentures with different implant angulations10.1111/clr.13567 ↗
21. Long-term retention behaviour of resin matrix attachment systems for overdentures10.1016/j.jmbbm.2015.11.038 ↗
22. Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws
23. Wear simulation effects on overdenture stud attachments10.4012/dmj.2011-057 ↗
24. Effects of interimplant distance and cyclic dislodgement on retention of LOCATOR and ball attachments: an in vitro study10.1016/j.prosdent.2018.12.023 ↗
25. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution10.11607/jomi.3067 ↗
26. Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study10.1016/S0022-3913(98)70133-7 ↗
27. The influence of interimplant divergence on the retention characteristics of locator attachments, a laboratory study10.1111/jopr.12144 ↗
28. Retention of implant-supported overdentures at different implant angulations: comparing Locator and ball attachments10.1111/clr.13003 ↗
29. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients - the York Consensus Statement10.1038/sj.bdj.2009.728 ↗
30. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures10.11607/jomi.3621 ↗
31. Evaluation of retention, wear, and maintenance of attachment systems for single- or two-implant-retained mandibular overdentures: a systematic review10.3390/ma15051933 ↗
32. Initial retention force of three attachment systems for implant retained-mandibular overdentures: an in vitro study
33. A randomized clinical trial comparing two mandibular implant overdenture designs: 3-year prosthetic outcomes using a six-field protocol
34. Retention and wear of resin matrix attachments for implant overdentures10.1016/j.jmbbm.2020.103901 ↗
35. Analysis of retention and wear of ball attachments
36. The effect of denture cleansing solutions on the retention of pink locator attachments after multiple pulls: an in vitro study10.1111/j.1532-849X.2011.00722.x ↗