Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study
Source abstract
Abstract
To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I–I-X (TL); T4: I–I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I–I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I–I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Impact of prosthetic material on mid- and long-term outcome of dental implants supporting single crowns and fixed partial dentures: a systematic review and meta-analysis
2. Clinical and radiographic changes at implants supporting single-unit crowns (SCs) and fixed dental prostheses (FDPs) with one cantilever extension. A retrospective study10.1111/j.1600-0501.2011.02391.x ↗
3. Implant survival and complications. The Third EAO consensus conference 201210.1111/j.1600-0501.2012.02557.x ↗
4. Fracture behavior of all-ceramic, implant-supported, and tooth–implant-supported fixed dental prostheses10.1007/s00784-017-2233-9 ↗
5. Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis10.1016/j.ijom.2016.01.004 ↗
6. Influence of shading technique on mechanical fatigue performance and optical properties of a 4Y-TZP ceramic for monolithic restorations10.1016/j.jmbbm.2019.103457 ↗
7. The influence of prosthetic material on implant and prosthetic survival of implant-supported fixed complete dentures: a systematic review and meta-analysis10.1016/j.jpor.2019.02.001 ↗
8. Clinical outcomes of implant abutments in the anterior region: a systematic review10.1111/jerd.12031 ↗
9. Technical and biological complications/failures with single crowns and fixed partial dentures on implants: a 10-year prospective cohort study10.1111/j.1600-0501.2005.01105.x ↗
10. Effect of internal connection type and screw channel angle on the screw stability of anterior implant-supported zirconia crowns10.1111/clr.14165 ↗
11. Influence of the titanium base abutment design on monolithic zirconia multiple-unit implant fixed dental prostheses: a laboratory study10.11607/jomi.8923 ↗
12. Comparison of external, internal flat-to-flat, and conical implant abutment connections for implant-supported prostheses: a systematic review and network meta-analysis of randomized clinical trials10.1016/j.prosdent.2021.09.029 ↗
13. Fracture force of cantilevered zirconia frameworks: an in vitro study10.1016/j.prosdent.2014.04.016 ↗
14. Single tooth bite forces in healthy young adults10.1046/j.0305-182X.2003.01179.x ↗
15. Effect of high-speed sintering on the flexural strength of hydrothermal and thermo-mechanically aged zirconia materials10.1016/j.dental.2020.05.013 ↗
16. Influence of abutment design on Stiffness, strength, and failure of implant-supported monolithic resin Nano ceramic (RNC) crowns10.1111/cid.12215 ↗
17. Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: a prospective clinical trial with a 2- year follow-up
18. Patient Reported Outcome Measures (PROMs) of posterior single‐implant crowns using digital workflows: a randomized controlled trial with a three‐year follow‐up
19. Mechanical stability of zirconia implant abutments supporting cantilevered fixed dental prostheses after fatigue loading10.11607/ijp.6700 ↗
20. Zirconia cantilever fixed dental prostheses supported by one or two implants: an in vitro study on mechanical stability and technical outcomes10.11607/jomi.8953 ↗
21. An in vitro test procedure for evaluating dental restauration systems. A computer-controlled mastication simulator
22. Ceramic versus metal-ceramic implant-supported prostheses: a systematic review and meta-analysis10.1016/j.prosdent.2018.09.016 ↗
23. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis10.1111/clr.12631 ↗
24. Soft tissues stability of cad-cam and stock abutments in anterior regions: 2-year prospective multicentric cohort study10.1111/clr.12479 ↗
25. Impact of hydrothermal aging on the light transmittance and flexural strength of colored yttria-stabilized zirconia materials of different formulations10.1016/j.prosdent.2020.01.016 ↗
26. Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: a systematic review10.1111/clr.13801 ↗
27. Mechanical behavior of posterior all-ceramic hybrid-abutment-crowns versus hybrid-abutments with separate crowns-A laboratory study10.1111/clr.13395 ↗
28. Clinical outcomes of partial and full-arch all-ceramic implant-supported fixed dental prostheses. A systematic review and meta-analysis10.1111/clr.13345 ↗
29. Mechanical stability of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns10.11607/jomi.7431 ↗
30. Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: an in vitro study10.1111/clr.13693 ↗
31. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years10.1111/j.1600-0501.2004.01117.x ↗
32. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)10.1111/j.1600-0501.2007.01439.x ↗
33. A systematic review and meta-analysis evaluating the survival, the failure, and the complication rates of veneered and monolithic all-ceramic implant-supported single crowns10.1111/clr.13863 ↗
34. Implant-supported fixed dental prostheses with cantilever extensions: State of the art and future perspectives
35. Clinical and radiographic outcomes of implant-supported zirconia fixed dental prostheses with cantilever extension: a proof-of-principle study with a follow-up of at least 1 year10.1111/clr.14138 ↗
36. Stability of cantilever fixed dental prostheses on zirconia implants10.3390/ma15103633 ↗
37. Distal cantilevers and implant dentistry
38. Resistance to fracture in fixed dental prostheses over cemented and screw-retained implant-supported zirconia cantilevers in the anterior region: an in vitro study10.11607/jomi.7899 ↗
39. Clinical and radiographic outcomes of implant-supported fixed dental prostheses with cantilever extension. A retrospective cohort study with a follow-up of at least 10 years10.1111/clr.13672 ↗
40. Clinical and radiographic evaluation of implant-supported single-unit crowns with cantilever extension in posterior areas: a retrospective study with a follow-up of at least 10 years10.1111/cid.12973 ↗
41. Clinical performance of one-piece, screw-retained implant crowns based on hand-veneered CAD/CAM zirconia abutments after a mean follow-up period of 2.3 years10.11607/jomi.5929 ↗
42. In vitro evaluation of a mechanical testing chewing simulator10.1016/j.dental.2008.09.010 ↗
43. Implant supported cantilevered fixed dental rehabilitations in partially edentulous patients: systematic review of the literature. Part I10.1111/clr.13311 ↗
44. Maximum voluntary molar bite force in subjects with normal occlusion10.1093/ejo/cjq097 ↗
45. Review of the mechanical behavior of different implant-abutment connections10.3390/ijerph17228685 ↗
46. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses10.1016/j.prosdent.2017.09.017 ↗
47. Failure analysis of high-performance polymers and new generation cubic zirconia used for implant-supported fixed, cantilevered prostheses10.1111/cid.12844 ↗