A mathematical approach to estimate micro-displacement of a dental implant using electromagnetic Frequency Response Analysis
Source abstract
Abstract
The aim of this paper is to formulate a mathematical model of dental prosthetic using single degree of freedom (SDOF) to assess the micro-displacement under electromagnetic excitation. Using Finite Element Analysis (FEA) and values from literature, stiffness and damping values of the mathematical model were estimated. For ensuring the successful implantation of dental implant system, monitoring of primary stability in terms of micro-displacement is crucial. One of the most popular techniques for the measurement of stability is the Frequency Response Analysis (FRA). This technique assesses the resonant frequency of vibration corresponding to the maximum micro-displacement (micro-mobility) of the implant. Among the different FRA techniques, the most common method is the Electromagnetic FRA. The subsequent displacement of the implant in the bone is estimated by equations of vibration. A comparison has been made to observe the variation in resonance frequency and micro-displacement due to varying input frequency ranges of 1-40 Hz. The micro-displacement and corresponding resonance frequency were plotted using MATLAB and the variation in resonance frequency is found to be negligible. The present mathematical model is a preliminary approach to understand the variation of micro-displacement with reference to electromagnetic excitation force and to obtain the resonance frequency. The present study validated the use of input frequency ranges (1-30 Hz) with negligible variation in micro-displacement and corresponding resonance frequency. However, input frequency ranges beyond 31-40 Hz is not recommended due to large variation in micromotion and corresponding resonance frequency.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Effects of pulsed electromagnetic field vibration on tooth movement induced by magnetic and mechanical forces: a preliminary study10.1111/j.1834-7819.2007.tb00503.x ↗
2. A simple mathematical model for the resonance frequency analysis of dental implant stability: implant clamping quotient10.1016/j.mechrescom.2018.12.004 ↗
3. Assessment of dental implant stability by means of the electromechanical impedance method10.1088/0964-1726/20/4/045008 ↗
4. Initial stability measurements of implants using a new magnetic resonance frequency analyzer with titanium transducers: an ex vivo study10.1563/aaid-joi-D-19-00126 ↗
5. The design of a vibration transducer to monitor the integrity of dental implants10.1243/0954411981534042 ↗
6. Cawley Peter · 2013
7. Mathematical equations for dental implant stability patterns during the osseointegration period, based on previous resonance frequency analysis studies10.1111/cid.12828 ↗
8. In vivo evaluation of a novel custom-made press-fit dental implant through electron beam Melting® (EBM®)
9. ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency10.1186/s40729-017-0105-3 ↗
10. A new numerical approach for evaluation of dental implant stability using electromagnetic impulse
11. Mathematical modeling of resonant linear vibratory conveyor with electromagnetic excitation: simulations and experimental results10.1016/j.apm.2016.09.010 ↗
12. Finite element analysis and experimental investigations on stress distribution of dental implants around implant-bone interface10.1016/j.matpr.2017.12.157 ↗
13. Significance of orthotropic material models to predict stress around bone-implant interface using numerical simulation10.1007/s12668-019-00649-5 ↗
14. Numerical investigation on stress intensity around Bone-Implant interface by 3-Dimensional FEA and experimental verification by optical technique10.1016/j.matpr.2020.06.097 ↗
15. The use and abuse of the periotest for 2-piece implant/abutment systems
16. Damping factor as a diagnostic parameter for assessment of osseointegration during the dental implant healing process: an experimental study in rabbits10.1007/s10439-016-1675-6 ↗
17. Biomechanical behaviours of the bone-implant interface: a review10.1098/rsif.2019.0259 ↗
18. Genta · Vibration Dynamics and Control · 2009 · 5710.1007/978-0-387-79580-5 ↗
19. Determination of stability of dental implant from impedance studies using Resonance Frequency Analysis
20. Reliability of the resonance frequency analysis values in new prototype transepithelial abutments: a prospective clinical study10.3390/ijerph17186733 ↗
21. Harirforoush · 2012 · 679
22. A no-contact vibration device for measuring implant stability10.1111/j.1600-0501.2010.01934.x ↗
23. Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study
24. Compliance with supportive periodontal treatment in patients with dental implants10.11607/jomi.5457 ↗
25. Finite element analysis of a dental implant10.4015/S1016237203000134 ↗
26. Assessing the implant/bone interface by using natural frequency analysis10.1067/moe.2000.108918 ↗
27. Design of a stability-detecting device for dental implants10.1243/095441105X9336 ↗
28. Establish a mechanical damping model for evaluating the surrounding soft tissue of dental implant10.1142/S0219519419400232 ↗
29. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments10.1111/j.1600-0501.2007.01419.x ↗
30. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation10.1556/imas.5.2013.4.3 ↗
31. A mathematical model for biomechanical evaluation of micro - motion in dental prosthetics using vibroacoustic RFA10.1007/s40846-021-00636-w ↗
32. Theoretical study of the effects of tooth and implant mobility differences on occlusal force transmission in tooth/implant-supported partial prostheses10.1016/S0022-3913(97)70047-7 ↗
33. Material properties of the mandibular trabecular bone
34. In vivo and in vitro natural frequency analysis of periodontal conditions: an innovative method10.1902/jop.2000.71.4.632 ↗
35. Assessment of implant stability as a prognostic determinant
36. A review of time-frequency methods for structural vibration analysis10.1016/S0141-0296(02)00194-3 ↗
37. Implant stability - measuring devices and randomized clinical trial for ISQ value change pattern measured from two different directions by magnetic RFA10.5772/18309 ↗
38. Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface10.1186/s12938-019-0733-3 ↗
39. Resonance frequency analysis for implant stability measurements. A review
40. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
41. An understanding of the mechanism that promotes adhesion between roughened titanium implants and mineralized tissue10.1115/1.3078163 ↗
42. Influence of clinically relevant factors on the immediate biomechanical surrounding for a series of dental implant designs10.1115/1.4003318 ↗
43. Evaluation of primary and secondary stability of titanium implants using different surgical techniques10.1111/clr.12180 ↗
44. Validation of value of actual micromotion as a direct measure of implant micromobility after healing (secondary implant stability)10.1111/clr.12756 ↗
45. Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial10.1902/jop.2007.060143 ↗
46. Application of the advanced system for implant stability testing (ASIST) to natural teeth for noninvasive evaluation of the tooth root interface10.1016/j.jbiomech.2018.01.023 ↗
47. Micromotion of dental implants: basic mechanical considerations10.1155/2013/265412 ↗
48. Modal analysis for implant stability assessment: sensitivity of this methodology for different implant designs10.1016/j.dental.2018.05.016 ↗