Customized root-analogue dental implants - Procedure and errors associated with image acquisition, treatment, and manufacturing technology in an experimental study on a cadaver dog mandible
Source abstract
Abstract
The global market for dental implants is constantly evolving. To overcome the limitations of conventional strategies - invasive surgeries and bone loss around the implant-, new approaches, namely the development of CAD/CAM customized implants, are emerging as promising solutions for replacing missing teeth, thus avoiding destruction of bone by drilling it. Despite the efforts that are being carried out, the designing, including image acquisition, and manufacturing efficacy of such rehabilitation therapy is not easily found in the literature. In this sense, this research work aimed to assess the errors associated with the image acquisition, treatment and manufacturing of Customized Root-Analogue Implants (CRAI). The experimental procedure, carried out in a dog cadaveric mandible, encompassed the image acquisition and treatment and the subsequent manufacturing of four different CRAI. Two Image acquisition methods (CBCT and X-ray), and different software for their treatment were used, and the final CRAI were manufactured by Computer Numerical Control. Results revealed the CBCT scan allowed to properly visualize the original teeth contours. However, all the obtained teeth geometries presented smaller surface areas when compared to the original teeth indicating however a systematic predictable error. On the other hand, when comparing the surface area of the digital and the manufactured teeth, very small differences were observed, which indicates that the CNC manufacturing technique is a promising solution for such applications. When placing the produced CRAI in the dog mandible it was possible to observe a lack of congruency between the CRAI and bone, mainly due to image acquisition process errors and the destruction of the periodontal ligament during the soft tissues removal process. Thus, CBCT images seem to be a feasible route to design root-analogue implants, and, if needed, a compensation strategy for the systematic image acquisition error may be implemented.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Radiography and Imaging · Dental Implant Techniques and Outcomes · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Subtractive computer-aided manufacturing in dental milling
2. Accuracy and precision of cone beam computed tomography in periodontal defects measurement (systematic review)10.4103/0972-124X.176389 ↗
3. Survival of short dental implants
4. A randomized clinical trial to evaluate and compare implants placed in augmented versus non-augmented extraction sockets: 3-year results10.1902/jop.2011.110205 ↗
5. Esthetic outcome of implants placed in fresh extraction sockets by clinicians with or without experience: a medium-term retrospective evaluation10.11607/jomi.4646 ↗
6. Reliability and accuracy of cone-beam computed tomography dental measurements10.1016/j.ajodo.2007.09.016 ↗
7. Accuracy and reliability of cone beam computed tomographic measurements of the bone labial and palatal to the maxillary anterior teeth10.11607/jomi.3856 ↗
8. Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment10.1186/s12903-015-0091-x ↗
9. Digital denture manufacturing-An integrated technologies of abrasive computer tomography, CNC machining and rapid prototyping10.1007/s00170-005-0181-z ↗
10. Design and manufacture of customized dental implants by using reverse engineering and selective laser melting technology10.1016/j.prosdent.2014.04.026 ↗
11. FEM investigation of the stress distribution overMandibular bone due to screwed overdenture positioned on dental implants10.3390/ma11091512 ↗
12. Radiological outcomes of bone-level and tissue-level dental implants: systematic review10.3390/ijerph17186920 ↗
13. 4-Axis CNC milling machine for production of dental prosthesis
14. In silico evaluation of the stress fields on the cortical bone surrounding dental implants: comparing root-analogue and screwed implants10.1016/j.jmbbm.2020.103667 ↗
15. Design and optimization of zirconia functional surfaces for dental implants applications10.1016/j.ceramint.2020.03.190 ↗
16. Customized root-analogue implants: a review on outcomes from clinical trials and case reports10.3390/ma14092296 ↗
17. Bacteria co-culture adhesion on different texturized zirconia surfaces10.1016/j.jmbbm.2021.104786 ↗
18. A new classification of peri implant gaps based on gap location (A case series of 210 immediate implants)10.4103/1735-3327.313124 ↗
19. Interventions for replacing missing teeth: augmentation procedures of the maxillary sinus10.1002/14651858.CD008397.pub2 ↗
20. Anatomic customization of root-analog dental implants with cone-beam ct and cad/cam fabrication: a cadaver-based pilot evaluation10.1563/aaid-joi-D-17-00090 ↗
21. Biomechanical behaviours of the bone-implant interface: a review10.1098/rsif.2019.0259 ↗
22. Determination of stress distribution on periodontal ligament and alveolar bone by various tooth movements – a 3D FEM study10.1016/j.jobcr.2020.10.011 ↗
23. The role of CBCT in implant dentistry: uses, benefits and limitations
24. Trial of a CAD/CAM system for fabricating complete dentures10.4012/dmj.2010-112 ↗
25. An overview of immediate root analogue zirconia implants10.1563/AAID-JOI-D-10-00208 ↗
26. Short dental implants versus standard dental implants placed in the posterior jaws: a systematic review and meta-analysis10.1016/j.jdent.2016.01.005 ↗
27. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images
28. Custom-made, root-analogue direct laser metal forming implant: a case report10.1007/s10103-012-1134-z ↗
29. Designing a novel dental root analogue implant using cone beam computed tomography and CAD/CAM technology10.1111/j.1600-0501.2011.02359.x ↗
30. A patient specific biomechanical analysis of custom root analogue implant designs on alveolar bone stress: a finite element study
31. Age-dependent changes of the mandible bone throughout the lifespan in female F344/N rat10.1111/joa.12868 ↗
32. Immediate, non submerged root analog zirconia implant in single rooted tooth replacement: case report with 2 years follow up10.1007/s12663-015-0786-1 ↗
33. Custom-made root-analogue zirconia implants: a scoping review on mechanical and biological benefits10.1002/jbm.b.34147 ↗
34. True anatomic immediate dental implant method
35. Root analog zirconia implants: true anatomical design for molar replacement-a case report
36. The role of IL-1 gene polymorphisms (IL1A, IL1B, and IL1RN) as a risk factor in unsuccessful implants retaining overdentures10.1016/j.jpor.2017.01.004 ↗
37. Peri-implantitis10.1111/jcpe.12954 ↗
38. Wear and corrosion interactions at the titanium/zirconia interface: dental implant application10.1111/jopr.12769 ↗
39. The application of CAD/CAM technology in Dentistry10.1088/1757-899X/200/1/012020 ↗
40. A comparative study of cone-beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars, Oral Surgery10.1016/j.tripleo.2006.06.060 ↗
41. Clinical behavior of short dental implants: systematic review and meta-analysis10.3390/jcm9103271 ↗
42. Crestal bone loss around dental implants after implantation of Tricalcium phosphate and Platelet- Rich Plasma: a comparative study10.4103/jfmpc.jfmpc_707_19 ↗
43. IL1 gene polymorphisms and unsuccessful dental implants10.1111/j.1600-0501.2011.02322.x ↗
44. Analysis of mechanical properties at different levels of the periodontal ligament
45. Comparison of 3-D printing and 5-axis milling for the production of dental e-models from intra-oral scanning10.1080/16864360.2015.1059186 ↗
46. A review of engineered zirconia surfaces in biomedical applications10.1016/j.procir.2017.04.057 ↗