journal article·2023-04

Applying a homogeneous pressure distribution to the upper vertebral endplate: Validation of a new loading system, pilot application to human vertebral bodies, and finite element predictions of DIC measured displacements and strains

Massimiliano Baleani, Giulia Fraterrigo, Paolo Erani, Giulia Rota, Matteo Berni, Fulvia Taddei, Enrico Schileo

Publisher page

Abstract

Image-based personalized Finite Element Models (pFEM) could detect alterations in physiological deformation of human vertebral bodies, but their accuracy has been seldom reported. Meaningful validation experiments should allow vertebral endplate deformability and ensure well-controlled boundary conditions. This study aimed to (i) validate a new loading system to apply a homogeneous pressure on the vertebral endplate during vertebral body compression regardless of endplate deformation; (ii) perform a pilot study on human vertebral bodies measuring surface displacements and strains with Digital Image Correlation (DIC); (iii) determine the accuracy of pFEM of the vertebral bodies. Homogeneous pressure application was achieved by pressurizing a fluid silicone encased in a rubber silicone film acting on the cranial endplate. The loading system was validated by comparing DIC-measured longitudinal strains and lower-end contact pressures, measured on three homogeneous pseudovertebrae of constant transversal section at 2.0 kN, against theoretically calculated values. Longitudinal strains and contact pressures were rather homogeneous, and their mean values close to theoretical calculations (5% underestimation). DIC measurements of surface longitudinal and circumferential displacements and strains were obtained on three human vertebral bodies at 2.0 kN. Complete displacement and strain maps were achieved for anterolateral aspects with random errors ≤0.2 μm and ≤30 μstrain, respectively. Venous plexus and double curvatures limited the completeness and accuracy of DIC data in posterior aspects. pFEM of vertebral bodies, including cortical bone mapping, were built from computed tomography images. In anterolateral aspects, pFEM accuracy of the three vertebrae was: (i) comparable to literature in terms of longitudinal displacements (R2>0.8); (ii) extended to circumferential displacements (pooled data: R2>0.9) and longitudinal strains (zero median error, 95% error: <27%). Circumferential strains were overestimated (median error: 39%). The new methods presented may permit to study how physiological and pathologic conditions influence the ability of vertebral endplates/bodies to sustain loads.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Medical Imaging and Analysis · Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (64)

Show source-provided references
1. Measurement of apparent mechanical properties of trabecular bone tissue: accuracy and limitation of digital image correlation technique10.1016/j.jmbbm.2019.103542 ↗
2. Experimentally achievable accuracy using a digital image correlation technique in measuring small-magnitude (<0.1%) homogeneous strain fields10.3390/ma11050751 ↗
3. A novel modelling methodology which predicts the structural behaviour of vertebral bodies under axial impact loading: a finite element and DIC study10.3390/ma13194262 ↗
4. Parametric convergence sensitivity and validation of a finite element model of the human lumbar spine10.1080/10255842.2010.493517 ↗
5. A combined passive and active musculoskeletal model study to estimate L4-L5 load sharing10.1016/j.jbiomech.2017.04.026 ↗
6. Inhomogeneity of human vertebral cancellous bone: systematic density and structure patterns inside the vertebral body10.1016/S8756-3282(01)00425-2 ↗
7. Assessment of digital image correlation measurement errors: methodology and results10.1007/s11340-008-9204-7 ↗
8. Development and validation of a musculoskeletal model of the fully articulated thoracolumbar spine and rib cage10.1115/1.4030408 ↗
9. Spinal loading patterns from biomechanical modeling explain the high incidence of vertebral fractures in the thoracolumbar region10.1002/jbmr.3113 ↗
10. Comparison of quantitative computed tomography-based measures in predicting vertebral compressive strength10.1016/j.bone.2006.10.025 ↗
11. A patient-specific finite element methodology to predict damage accumulation in vertebral bodies under axial compression, sagittal flexion and combined loads10.1080/10255840802078022 ↗
12. Vertebral strength prediction under anterior compressive force using a finite element model for osteoporosis assessment10.1080/10255842.2015.1069562 ↗
13. MeshLab: an open-source mesh processing tool
14. Micro Finite Element models of the vertebral body: validation of local displacement predictions10.1371/journal.pone.0180151 ↗
15. Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography10.1016/S8756-3282(03)00210-2 ↗
16. Strain distribution in the lumbar vertebrae under different loading configurations10.1016/j.spinee.2013.06.014 ↗
17. A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro10.1016/j.jbiomech.2010.04.023 ↗
18. Digital image correlation (DIC) for measurement of strains and displacements in coarse, low volume-fraction FRP composites used in civil infrastructure10.1016/j.compstruct.2019.01.024 ↗
19. The dependence of transversely isotropic elasticity of human femoral cortical bone on porosity10.1016/j.jbiomech.2003.12.011 ↗
20. Prediction of cortical bone elastic constants by a two-level micromechanical model using a generalized self-consistent method10.1115/1.2187039 ↗
21. Cortical and trabecular load sharing in the human vertebral body10.1359/jbmr.2006.21.2.307 ↗
22. Thoracolumbar spine mechanics contrasted under compression and shear loading10.1016/S0736-0266(02)00058-X ↗
23. Experimental validation of a subject-specific finite element model of lumbar spine segment using digital image correlation10.1371/journal.pone.0272529 ↗
24. Experimental validation of finite element model for proximal composite femur using optical measurements10.1016/j.jmbbm.2013.02.006 ↗
25. Case-specific non-linear finite element models to predict failure behavior in two functional spinal units10.1002/jor.24117 ↗
26. Comparison of specimen-specific vertebral body finite element models with experimental digital image correlation measurements10.1016/j.jmbbm.2016.10.002 ↗
27. Damage identification on vertebral bodies during compressive loading using digital image correlation10.1097/BRS.0000000000002156 ↗
28. Digital Image Correlation for discontinuous displacement measurement using subset segmentation10.1016/j.optlaseng.2018.12.003 ↗
29. Differences in trabecular microarchitecture and simplified boundary conditions limit the accuracy of quantitative computed tomography-based finite element models of vertebral failure10.1115/1.4038609 ↗
30. Nonlinear finite element model predicts vertebral bone strength and fracture site10.1097/01.brs.0000225993.57349.df ↗
31. Accuracy of finite element analyses of CT scans in predictions of vertebral failure patterns under axial compression and anterior flexion10.1016/j.jbiomech.2015.12.004 ↗
32. Endplate deflection is a defining feature of vertebral fracture and is associated with properties of the underlying trabecular bone10.1002/jor.22620 ↗
33. Quantitative, 3D visualization of the initiation and progression of vertebral fractures under compression and anterior flexion10.1002/jbmr.2749 ↗
34. Uniaxial compression testing of polymeric materials10.1016/j.polymertesting.2009.12.003 ↗
35. Measurement and analyses of the effects of adjacent end plate curvatures on vertebral stresses10.1016/j.spinee.2005.09.008 ↗
36. A practical approach to optimizing the preparation of speckle patterns for digital-image correlation10.1088/0957-0233/25/10/107001 ↗
37. Strain changes on the cortical shell of vertebral bodies due to spine ageing: a parametric study using a finite element model evaluated by strain measurements10.1177/0954411913501293 ↗
38. Characteristics of a prevalent vertebral deformity predict subsequent vertebral fracture: results from the European Prospective Osteoporosis Study (EPOS)10.1016/S8756-3282(03)00248-5 ↗
39. Embedding of human vertebral bodies leads to higher ultimate load and altered damage localisation under axial compression10.1080/10255842.2012.744400 ↗
40. Association of vertebral endplate microstructure with bone strength in men and women10.1016/j.bone.2019.115147 ↗
41. On prediction of the strength levels and failure patterns of human vertebrae using quantitative computed tomography (QCT)-based finite element method10.1016/j.jbiomech.2009.04.042 ↗
42. A comparison of 2D and 3D digital image correlation for a membrane under inflation10.1016/j.optlaseng.2015.07.013 ↗
43. Biomechanical characteristics of human trabecular bone10.1016/S0268-0033(97)00035-1 ↗
44. The size of simulated lytic metastases affects the strain distribution on the anterior surface of the vertebra10.1115/1.4040587 ↗
45. Use of digital image correlation to investigate the biomechanics of the vertebra10.1142/S0219519415400047 ↗
46. A novel approach to evaluate the effects of artificial bone focal lesion on the three-dimensional strain distributions within the vertebral body10.1371/journal.pone.0251873 ↗
47. Study on subset size selection in digital image correlation for speckle patterns10.1364/OE.16.007037 ↗
48. Human lumbar vertebrae. Quantitative three-dimensional anatomy10.1097/00007632-199203000-00010 ↗
49. Loads on a vertebral body replacement during locomotion measured in vivo10.1016/j.gaitpost.2013.10.010 ↗
50. Lifting up and laying down a weight causes high spinal loads10.1016/j.jbiomech.2012.10.022 ↗
51. An accurate estimation of bone density improves the accuracy of subject-specific finite element models10.1016/j.jbiomech.2008.05.017 ↗
52. Cortical bone mapping improves finite element strain prediction accuracy at the proximal femur10.1016/j.bone.2020.115348 ↗
53. Schreier · 2009
54. The distribution of surface strain in the cadaveric lumbar spine10.1302/0301-620X.60B2.659474 ↗
55. Ultrahigh molecular weight polyethylene
56. The effect of out-of-plane motion on 2D and 3D digital image correlation measurements10.1016/j.optlaseng.2008.05.005 ↗
57. Independent measurement of femoral cortical thickness and cortical bone density using clinical CT10.1016/j.media.2014.11.012 ↗
58. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone10.1016/S8756-3282(99)00098-8 ↗
59. Burst fracture in the metastatically involved spine: development, validation, and parametric analysis of a three-dimensional poroelastic finite-element model10.1097/01.BRS.0000051910.97211.BA ↗
60. A parametric study of DIC measurement uncertainties on cracked metals10.1111/str.12291 ↗
61. Study of optimal subset size in digital image correlation of speckle pattern images10.1016/j.optlaseng.2007.01.012 ↗
62. Noninvasive prediction of vertebral body compressive strength using nonlinear finite element method and an image based technique10.1016/j.ejmp.2009.08.002 ↗
63. The effects of biomechanical factors on adjacent vertebral compression fractures after percutaneous kyphoplasty: a propensity score matching analysis10.1007/s00198-022-06428-5 ↗
64. Subpixel displacement and deformation gradient measurement using digital image/speckle correlation (DISC)10.1117/1.1387992 ↗