journal article·2024-04Open access

Thermoplastic clear dental aligners under cyclic compression loading: A mechanical performance analysis using acoustic emission technique

Claudia Barile, Claudia Cianci, Vimalathithan Paramsamy Kannan, Giovanni Pappalettera, Carmine Pappalettere, Caterina Casavola, Carmela Suriano, Domenico Ciavarella

Abstract

The objective of this work is to analyse the performance of clear aligners made of thermoplastic materials. Within this framework, the damage evolution stages and damage states of the aligners at different cycles of the compressive loading are evaluated using the Acoustic Emission (AE) technique. Three different clear aligner systems were prepared: thermoformed PET-g (polyethylene terephthalate glycol) and PU (polyurethane), and additively manufactured PU. Cyclic compression tests are performed to simulate 22500 swallows. The mechanical results show that the energy absorbed by the thermoformed PET-g aligner remains stable around 4 Nmm throughout the test. Although the PU-based aligners show a higher energy absorption of about 7 Nmm during the initial phase of the cyclic loading, this gradually decreases after 12500 cycles. The time-domain based, and frequency-based parameters of the stress wave acoustic signals generated by the aligners under compression loading are used to identify the damage evolution stages. The machine learning-based AE results reveal the initiation and termination of the different damage states in the aligners and the frequency-based results distinguish the different damage sources. Finally, the microscopy results validated the damage occurrences in the aligners identified by the AE results. The mechanical test results indicate that the thermoformed PET-g has the potential to match the performance and requirements of the dentistry of the popular Invisalign (additively manufactured PU). The AE results have the potential to identify at which cycles the aligners may start losing their functionality.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental materials and restorations · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Analysis of EEG background activity in Alzheimer's disease patients with Lempel–Ziv complexity and central tendency measure10.1016/j.medengphy.2005.07.004 ↗
2. Interpretation of the Lempel-Ziv complexity measure in the context of biomedical signal analysis10.1109/TBME.2006.883696 ↗
3. Acoustic emission for fatigue damage characterization in metal plates10.1016/j.mechrescom.2011.01.011 ↗
4. Evaluation of mechanical properties of different thermoplastic orthodontic retainer materials after thermoforming and Thermocycling10.3390/polym15071610 ↗
5. A review on Vat Photopolymerization 3D-printing processes for dental application10.1016/j.dental.2022.09.005 ↗
6. Transverse cracking in carbon fiber reinforced polymer composites: modal acoustic emission and peak frequency analysis10.1016/j.compscitech.2015.05.005 ↗
7. Interpreting the Lempel–Ziv complexity of acoustic emission signals for identifying damage modes in composite materials10.1177/14759217221112831 ↗
8. Application of different acoustic emission descriptors in damage assessment of fiber reinforced plastics: a comprehensive review10.1016/j.engfracmech.2020.107083 ↗
9. Damage characterization in composite materials using acoustic emission signal-based and parameter-based data10.1016/j.compositesb.2019.107469 ↗
10. Mechanical and Geometrical properties assessment of thermoplastic materials for biomedical application
11. The Invisalign system in adult orthodontics: mild crowding and space closure cases
12. Response based damage assessment using acoustic emission energy for plain concrete10.1016/j.conbuildmat.2020.121241 ↗
13. Referring adult patients for orthodontic treatment10.14219/jada.archive.1999.0031 ↗
14. A full-field DIC analysis of the mechanical-deformation behavior of polyethylene terephthalate glycol (PET-G) aligners10.1016/j.jmbbm.2022.105391 ↗
15. Mechanical behavior of PET-G tooth aligners under cyclic loading10.3389/fmats.2020.00104 ↗
16. On the complexity measures of genetic sequences10.1093/bioinformatics/15.12.994 ↗
17. Finite strain behavior of poly (ethylene terephthalate)(PET) and poly (ethylene terephthalate)-glycol (PETG)10.1016/j.polymer.2005.03.083 ↗
18. Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study10.1034/j.1600-0501.2000.011005465.x ↗
19. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance10.1016/j.ajodo.2004.09.015 ↗
20. Force decay of polyethylene terephthalate glycol aligner materials during simulation of typical clinical loading/unloading scenarios
21. Initial versus final fracture of metal-free crowns, analyzed via acoustic emission10.1016/j.dental.2008.04.010 ↗
22. A density-based algorithm for discovering clusters in large spatial databases with noise
23. Dynamic stress relaxation of orthodontic thermoplastic materials in a simulated oral environment10.4012/dmj.2013-131 ↗
24. Occlusal forces during chewing and swallowing as measured by sound transmission10.1016/0022-3913(81)90455-8 ↗
25. Dislocation motions and acoustic emissions
26. Designing biostable polyurethane elastomers for biomedical implants10.1071/CH02168 ↗
27. Thirty years of advances and some remaining challenges in the application of acoustic emission to composite materials
28. Acoustic emission technology-based multifractal and unsupervised clustering on crack damage monitoring for low-carbon steel10.1016/j.measurement.2023.113042 ↗
29. Effects of temperature changes and stress loading on the mechanical and shape memory properties of thermoplastic materials with different glass transition behaviours and crystal structures10.1093/ejo/cjv013 ↗
30. Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances10.2319/052512-432.1 ↗
31. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign10.1016/j.ajodo.2007.05.018 ↗
32. Changes in mechanical behavior during fatigue of semicrystalline thermoplastics10.1002/app.1995.070580504 ↗
33. Non-destructive examination of interfacial debonding using acoustic emission10.1016/j.dental.2011.06.002 ↗
34. An introduction to acoustic emission10.1520/STP35377S ↗
35. Optical properties of orthodontic aligners—spectrophotometry analysis of three types before and after aging10.1186/s40510-015-0111-z ↗
36. Stress relaxation properties of four orthodontic aligner materials: a 24-hour in vitro study10.2319/113015-813.1 ↗
37. Crack classification in concrete based on acoustic emission10.1016/j.conbuildmat.2010.05.004 ↗
38. Changes in roughness and mechanical properties of Invisalign® appliances after one-and two-weeks use10.3390/ma12152406 ↗
39. A review of the biostability and carcinogenicity of polyurethanes in medicine and the new generation of’biostable’polyurethanes10.1163/156856294X00347 ↗
40. Topographical and optical characteristics of thermoplastic dental appliances materials related to water sorption10.3390/jfb14040190 ↗
41. Stress–strain behavior of thermoplastic polyurethanes10.1016/j.mechmat.2004.08.001 ↗
42. A spectroscopic study on orthodontic aligners: first evidence of secondary microplastic detachment after seven days of artificial saliva exposure
43. Estimating regularity in epileptic seizure time-series data10.1109/51.677174 ↗
44. Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review10.2319/061614-436.1 ↗
45. Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners10.4041/kjod.2018.48.5.316 ↗
46. Damage characterization of laminated composites using acoustic emission: a review10.1016/j.compositesb.2020.108039 ↗
47. Density-based clustering in spatial databases: the algorithm gdbscan and its applications10.1023/A:1009745219419 ↗
48. Strain induced strengthening of soft thermoplastic polyurethanes under cyclic deformation10.1002/pol.20210060 ↗
49. Structural conformation and leaching from in vitro aged and retrieved Invisalign appliances10.1016/j.ajodo.2004.04.021 ↗
50. Flexural behavior of PEEK materials for dental application10.1016/j.dental.2015.08.151 ↗
51. A comprehensive study on the mechanical effects of implant-supported prostheses under multi-directional loading and different occlusal contact points10.1186/s12903-023-03016-9 ↗
52. Mechanical properties of thermoplastic polymers for aligner manufacturing: in vitro study10.3390/dj8020047 ↗
53. Use of woven glass fibres to reinforce a composite veneer. A fracture resistance and acoustic emission study10.1046/j.1365-2842.2002.00915.x ↗
54. Fretting behavior of thermoplastic polyurethanes10.3390/lubricants7090073 ↗
55. Preparation and characterization of thermoplastic materials for invisible orthodontics10.4012/dmj.2011-120 ↗