Abstract

Purpose Acute ischemic stroke is a leading cause of death and morbidity worldwide. Despite advances in medical technology, nearly 30% of strokes result in incomplete vessel recanalization. Recent studies have demonstrated that clot composition correlates with success rates of mechanical thrombectomy procedures. To understand clot behavior during thrombectomy, which exerts considerable strains on thrombi, in vitro studies must characterize the rate-dependent high-strain behavior of embolus analogs (EAs) with different formation conditions, which can be used to fit models of hyper-viscoelasticity. Methods In this study, the effect of collagen infiltration as a carotid-induced collagen-rich thrombosis surrogate is considered as a contributor to embolus analog high-strain stiffness, when compared to 40% hematocrit EAs. Results EA high-strain stiffnesses, characterized on a uniaxial load frame, increase by an order of magnitude for collagenous clot analogs. Chandler loop analogs show high-strain stiffnesses and clot compositions commensurate with previous reports of stroke patient clots, and collagenous clots show significant increase in stiffness when compared to stroke patient clots. Finally, hyper-viscoelastic curve fitting demonstrates the asymmetry between tension and compression. Nonlinear, rate-dependent models that consider clot-stiffening behavior match the high strain stiffness of clots fairly well. Furthermore, we demonstrate that the stability of the elastic energy needs to be considered to obtain optimal curve fits for high-strain, rate dependent data. Conclusion This study provides a framework for the development of dynamically formed EAs that mimic the mechanical and structural properties of in vivo clots and provides parameters for numerical simulation of clot behavior with hyper-viscoelastic models.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Blood properties and coagulation · Elasticity and Material Modeling · Acute Ischemic Stroke Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (66)

Show source-provided references
1. Diverse thrombus composition in thrombectomy stroke patients with longer time to recanalization10.1016/j.thromres.2021.11.018 ↗
2. Continuum model of a thermoelastic solid capable of undergoing phase transitions10.1016/0022-5096(93)90048-K ↗
3. Provisional mortality data — United States, 202210.15585/mmwr.mm7218a3 ↗
4. Thrombus migration paradox in patients with acute ischemic stroke10.1161/STROKEAHA.119.026107 ↗
5. A viscoelastic fluid model for describing the mechanics of a coarse ligated plasma clot10.1007/s00162-006-0019-9 ↗
6. Astm d638-22: standard test method for tensile properties of plastics. Book of standards
7. Artificial stroke clots: how wide is the gap to the real world?10.1016/j.wneu.2017.10.090 ↗
8. Some properties of the hessian matrix of a strictly convex function10.1515/crll.1962.210.65 ↗
9. Modeling flow in an in vitro anatomical cerebrovascular model with experimental validation10.3389/fmedt.2023.1130201 ↗
10. Thrombus histology suggests cardioembolic cause in cryptogenic stroke10.1161/STROKEAHA.116.013105 ↗
11. Mechanical characterization of thrombi retrieved with endovascular thrombectomy in patients with acute ischemic stroke10.1161/STROKEAHA.120.033527 ↗
12. More than three passes of stent retriever is an independent predictor of parenchymal hematoma in acute ischemic stroke10.1136/neurintsurg-2018-014380 ↗
13. Tensile and compressive mechanical behaviour of human blood clot analogues10.1007/s10439-023-03181-6 ↗
14. Chernysh
15. Influence of fibrin network conformation and fibrin fiber diameter on fibrinolysis speed10.1161/01.ATV.20.5.1354 ↗
16. Methodical fitting for mathematical models of rubber-like materials10.1098/rspa.2016.0811 ↗
17. Acute ischemic stroke thrombi have an outer shell that impairs fibrinolysis10.1212/WNL.0000000000008395 ↗
18. Acute ischemic stroke thrombi have an outer shell that impairs fibrinolysis10.1212/WNL.0000000000008395 ↗
19. A high resolution scanning electron microscopy analysis of intracranial thrombi embedded along the stent retrievers10.1038/s41598-022-11830-4 ↗
20. Measuring the effect of thrombosis, thrombus maturation and thrombolysis on clot mechanical properties in an in-vitro model10.1016/j.jbiomech.2021.110731 ↗
21. Risk and secondary prevention of stroke recurrence: a population-base cohort study10.1161/STROKEAHA.120.028992 ↗
22. Ch. 1
23. Blood clot behaves as a poro-visco-elastic material10.1016/j.jmbbm.2022.105101 ↗
24. Blood clot behaves as a poro-visco-elastic material10.1016/j.jmbbm.2022.105101 ↗
25. The influence of blood composition and loading frequency on the behavior of embolus analogs10.1016/j.jmbbm.2023.105738 ↗
26. Hydrodynamics in acute ischemic stroke catheters under static and cyclic aspiration conditions10.1007/s13239-020-00503-w ↗
27. Thrombus composition and thrombolysis resistance in stroke10.1016/j.rpth.2023.100178 ↗
28. Holzapfel · 2000 · 455
29. A new constitutive framework for arterial wall mechanics and a comparative study of material models10.1023/A:1010835316564 ↗
30. Review of mechanical testing and modelling of thrombus material for vascular implant and device design10.1007/s10439-017-1906-5 ↗
31. Development of an in vitro model of calcified cerebral emboli in acute ischemic stroke for mechanical thrombectomy evaluation10.1136/neurintsurg-2019-015595 ↗
32. Investigating the mechanical behavior of clot analogues through experimental and computational analysis10.1007/s10439-020-02570-5 ↗
33. Mechanical properties of blood clots – a new test method10.1002/mawe.201000703 ↗
34. Role of fibrin structure in thrombosis and vascular disease10.1016/B978-0-12-381262-9.00003-3 ↗
35. Multimodality characterization of the clot in acute stroke10.3389/fneur.2021.760148 ↗
36. Lai
37. Changes in the structure-function relationship of elastin and its impact on the proximal pulmonary arterial mechanics of hypertensive calves10.1152/ajpheart.00127.2008 ↗
38. Spectrin-level modeling of the cytoskeleton and optical tweezers stretching of the erythrocyte10.1529/biophysj.104.047332 ↗
39. An introduction to the ogden model in biomechanics: benefits, implementation tools and limitations
40. Applicability assessment of a stent-retriever thrombectomy finite-element model10.1098/rsfs.2019.0123 ↗
41. Characterization of the “white” appearing clots that cause acute ischemic stroke10.1016/j.jstrokecerebrovasdis.2021.106127 ↗
42. Montgomery · 2014 · 813
43. Ogden · 1997 · 532
44. Modeling acute ischemic stroke recanalization through cyclic aspiration10.1016/j.jbiomech.2021.110721 ↗
45. Biologically informed clot histomics are predictive of acute ischemic stroke etiology
46. Computational analysis of effects of clot length on acute ischemic stroke recanalization under different cyclic aspiration loading conditions10.1002/cnm.3667 ↗
47. Hyper-viscoelastic damage modeling of whole blood clot under large deformation10.1007/s10237-021-01467-z ↗
48. The impact of recanalization on ischemic stroke outcome10.1161/01.STR.0000258112.14918.24 ↗
49. The importance of size10.1161/STROKEAHA.110.609693 ↗
50. Increased von Willebrand Factor, P-Selectin and Fibrin Content in Occlusive Thrombus Resistant to Lytic Therapy10.1160/TH15-12-0985 ↗
51. Elasticity-based polymer sorting in active fluids: a brownian dynamics study10.1039/C7CP02947K ↗
52. Medical textiles as vascular implants and their success to mimic natural arteries10.3390/jfb6030500 ↗
53. Mechanics of rouleau formation10.1016/S0006-3495(81)84826-6 ↗
55. Histological clot composition is associated with preinterventional clot migration in acute stroke patients10.1161/STROKEAHA.118.023314 ↗
56. Small thrombus size, thrombus composition, and poor collaterals predict pre-interventional thrombus migration10.1136/neurintsurg-2020-016228 ↗
57. In vitro blood clot formation and dissolution for testing new stroke-treatment devices10.3390/biomedicines10081870 ↗
58. Toward understanding thrombus fracture: dissipative phenomena of whole blood clots
59. Stress-strain data for vulcanised rubber under various types of deformation10.1039/tf9444000059 ↗
60. Kinetics and mechanics of clot contraction are governed by the molecular and cellular composition of the blood10.1182/blood-2015-05-647560 ↗
61. Rupture of blood clots: mechanics and pathophysiology10.1126/sciadv.abc0496 ↗
62. Heart disease and stroke statistics-2021 update A report from the American heart association. Circulation
63. Fibrinogen and fibrin10.1016/S0065-3233(05)70008-5 ↗
64. Fibrin Formation, structure and properties10.1007/978-3-319-49674-0_13 ↗
65. Red blood cells: the forgotten player in hemostasis and thrombosis10.1111/jth.14360 ↗
66. In vitro blood clot formation and dissolution for testing new stroke-treatment devices10.3390/biomedicines10081870 ↗