Comparative retrieval analysis of contemporary mobile and fixed unicompartmental knee bearing designs
Source abstract
Abstract
There are two different concepts behind Unicompartmental Knee Replacement (UKR). Mobile bearings, as exemplified by the Oxford UKR, and fixed bearings, as exemplified by the Physica ZUK. These are the two most commonly implanted UKRs in the UK. For the first time, a comparison of the tribological features of 19 explanted Oxford and 19 explanted Physica ZUK UKRs was undertaken. Surface damage on the polyethylene (PE) inserts of the Oxford and Physica ZUK cohorts were assessed using an established semi-quantitative scoring method. The femoral components of both cohorts were assessed using a non-contact 3D profilometer to measure roughness values. It was found that the PE inserts of the Oxford cohort (22.54 ± 9.14) had statistically significant greater damage scores than the Physica ZUK cohort (16.50 ± 5.17) (p = 0.04). However, the femoral components of the Oxford cohort showed lower roughness values than the Physica ZUK cohort (p = 0.00). This is the first study that reports a comparative roughness analysis between retrieved Oxford and Physica ZUK UKR designs.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Knee injuries and reconstruction techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Alvarez · 2012
2. Polyethylene wear in unicondylar knee prostheses. 106 retrieved Marmor, PCA, and St Georg tibial components compared10.3109/17453679209154776 ↗
3. Semi-quantitative assessment methods for backside polyethylene damage in modular total knee replacements10.1016/j.triboint.2011.12.011 ↗
4. First tribological assessment of retrieved Oxinium patellofemoral prostheses10.1016/j.jmbbm.2018.11.018 ↗
5. Retrieval analysis of two contemporary total knee designs: influence of femoral component roughness and type of polyethylene10.1016/j.jmbbm.2020.103620 ↗
6. Influence of microscopic surface asperities on the wear of ultra-high molecular weight polyethylene in a knee prosthesis10.1243/09544119JEIM690 ↗
7. Does patellofemoral disease affect outcomes in contemporary medial fixed-bearing unicompartmental knee arthroplasty?10.1016/j.arth.2020.03.007 ↗
8. Bearing thickness is not a predictive factor for damage and penetration in Oxford unicompartmental knee arthroplasty-A retrieval analysis10.3390/ma13204589 ↗
9. Roughness parameters10.1016/S0924-0136(02)00060-2 ↗
10. Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms10.1016/j.actbio.2013.05.005 ↗
11. Clinical results and 12-year survivorship of the Physica ZUK unicompartmental knee replacement10.1016/j.knee.2019.02.016 ↗
12. Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation10.1016/j.clinbiomech.2010.03.013 ↗
13. A pictographic atlas for classifying damage modes on polyethylene bearings10.1007/s10856-011-4303-x ↗
14. Retrieved unicompartmental implants with full PE tibial components: the effects of knee alignment and polyethylene thickness on creep and wear10.2174/1874325000802010051 ↗
15. Changes in surface topography at the TKA backside articulation following in vivo service: a retrieval analysis10.1007/s00167-014-3197-9 ↗
16. Unicompartmental knee arthroplasty
17. Joyce · Biopolym. Tribol. Handb. Polym.Tribol. · 2018 · 11110.1142/9789813227798_0004 ↗
18. T. Joyce, D. Langton, S. Jameson, A. Nargol, Tribological analysis of failed resurfacing hip prostheses and comparison with clinical data, Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology 223(3) (2009) 317-323.10.1243/13506501JET484 ↗
19. Quantification of self-polishing in vivo from explanted metal-on-metal total hip replacements10.1016/j.triboint.2010.04.007 ↗
20. Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years, the Journal of bone and joint surgery
21. A comparative surface topographical analysis of explanted total knee replacement prostheses: oxidised zirconium vs cobalt chromium femoral components10.1016/j.medengphy.2017.10.003 ↗
22. Unicompartmental knee arthroplasty: state of the art10.1136/jisakos-2016-000102 ↗
23. Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis10.1302/2046-3758.83.BJR-2018-0193.R1 ↗
24. The significance of surface changes on retrieved femoral components after total knee replacement
25. Unicondylar knee retrieval analysis10.1016/j.arth.2010.05.004 ↗
26. Transepicondylar axis in normal, varus, and valgus knee
27. BS EN ISO 25178-2-2012, Geometrical Product Specification (GPS) - Surface Texture: Areal, Part 2: Terms, Definitions and Surface Texture Parameters 2012.
28. 2020
29. Examination of ten fractured Oxford unicompartmental knee bearings, the Journal of bone and joint surgery
30. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens, the Journal of bone and joint surgery
31. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints10.1002/(SICI)1097-4636(2000)53:1<111::AID-JBM15>3.0.CO;2-Y ↗
32. 2021
33. 2021
34. Analysis of the surface topography of retrieved metal-on-polyethylene reverse shoulder prostheses10.1177/0954411920935757 ↗
35. Effect of CoCr counterface roughness on the wear of UHMWPE in the noncyclic RandomPOD simulation10.1115/1.4033648 ↗
36. Topographical analysis of the femoral components of ex vivo total knee replacements10.1007/s10856-012-4815-z ↗
37. The effect of bearing congruency, thickness and alignment on the stresses in unicompartmental knee replacements10.1016/j.clinbiomech.2008.06.001 ↗
38. Comparison of articular and backside polyethylene wear in mobile bearing unicompartmental knee replacement10.1016/j.knee.2016.12.010 ↗
39. Why do medial unicompartmental knee arthroplasties fail today?10.1016/j.arth.2015.11.030 ↗
40. The impact of sterilization method on wear in knee arthroplasty10.1097/00003086-199811000-00024 ↗