journal article·2024-09Open access

Effectiveness of energy absorbing floors in reducing hip fractures risk among elderly women during sideways falls

Qi Huang, Zhou Zhou, Svein Kleiven

Abstract

Falls among the elderly cause a huge number of hip fractures worldwide. Energy absorbing floors (EAFs) represent a promising strategy to decrease impact force and hip fracture risk during falls. Femoral neck force is an effective predictor of hip injury. However, the biomechanical effectiveness of EAFs in terms of mitigating femoral neck force remains largely unknown. To address this, a whole-body computational model representing a small-size elderly woman with a biofidelic representation of the soft tissue near the hip region was employed in this study, to measure the attenuation in femoral neck force provided by four commercially available EAFs (Igelkott, Kradal, SmartCells, and OmniSports). The body was positioned with the highest hip force with a −10∘ trunk angle and +10∘ anterior pelvis rotation. At a pelvis impact velocity of 3 m/s, the peak force attenuation provided by four EAFs ranged from 5% to 19%. The risk of hip fractures also demonstrates a similar attenuation range. The results also exhibited that floors had more energy transferred to their internal energy demonstrated greater force attenuation during sideways falls. By comparing the biomechanical effectiveness of existing EAFs, these results can improve the floor design that offers better protection performance in high-fall-risk environments for the elderly.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Balance, Gait, and Falls Prevention · Injury Epidemiology and Prevention · Diabetic Foot Ulcer Assessment and Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (77)

Show source-provided references
1. Declining incidence of hip fractures and the extent of use of anti-osteoporotic therapy in Denmark 1997–200610.1007/s00198-009-0957-3 ↗
2. Factors associated with mortality and functional disability after hip fracture: an inception cohort study10.1007/s00198-004-1740-0 ↗
3. Gender disparities in osteoporosis10.14740/jocmr2970w ↗
4. Analysis of loading to the hip joint in fall using whole-body FE model10.1016/j.jbiomech.2022.111262 ↗
5. Energy absorption during impact on the proximal femur is affected by body mass index and flooring surface10.1016/j.jbiomech.2014.04.026 ↗
6. Contribution of trochanteric soft tissues to fall force estimates, the factor of risk, and prediction of hip fracture risk10.1359/jbmr.070309 ↗
7. Estimating hip fracture morbidity, mortality and costs10.1046/j.1532-5415.2003.51110.x ↗
8. Modeling the body/chair interaction–an integrative experimental–numerical approach10.1016/S0268-0033(99)00073-X ↗
9. The penn state safety floor: Part II–reduction of fall-related peak impact forces on the femur10.1115/1.2798023 ↗
10. Depth-dependent compressive properties of normal aged human femoral head articular cartilage: relationship to fixed charge density10.1053/joca.2001.0424 ↗
11. Effects of hip joint kinematics on the effective pelvis stiffness and hip impact force during simulated sideways falls10.1016/j.jbiomech.2023.111885 ↗
12. Effect of pelvis impact angle on stresses at the femoral neck during falls10.1016/j.jbiomech.2018.04.015 ↗
13. Relationship of weight, height, and body mass index with fracture risk at different sites in postmenopausal women: the Global Longitudinal study of Osteoporosis in Women (GLOW)10.1002/jbmr.2051 ↗
14. Body mass index as a predictor of fracture risk: a meta-analysis10.1007/s00198-005-1863-y ↗
15. The SAFEST review: a mixed methods systematic review of shock-absorbing flooring for fall-related injury prevention10.1186/s12877-021-02670-4 ↗
16. Ranking and rating bicycle helmet safety performance in oblique impacts using eight different brain injury models10.1007/s10439-020-02703-w ↗
17. Current playground surface test standards underestimate brain injury risk for children10.1016/j.jbiomech.2019.03.038 ↗
18. Reducing hip fracture risk during sideways falls: evidence in young adults of the protective effects of impact to the hands and stepping10.1016/j.jbiomech.2007.01.019 ↗
19. On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact10.1371/journal.pone.0200952 ↗
20. Subject-specific ex vivo simulations for hip fracture risk assessment in sideways falls10.1016/j.bone.2019.05.004 ↗
21. Explicit finite element models accurately predict subject-specific and velocity-dependent kinetics of sideways fall impact10.1002/jbmr.3804 ↗
22. Finite element derived femoral strength is a better predictor of hip fracture risk than aBMD in the AGES Reykjavik study cohort10.1016/j.bone.2021.116219 ↗
23. Mean body weight, height, waist circumference, and body mass index among children and adolescents: United States, 1999–2018
24. Prophylactic augmentation implants in the proximal femur for hip fracture prevention: An in silico investigation of simulated sideways fall impacts10.1016/j.jmbbm.2021.104957 ↗
25. Hip fractures among the elderly in a Swedish urban setting: different perspectives on the significance of country of birth10.1080/14034940600733925 ↗
26. The influence of fall direction and hip protector on fracture risk: FE model predictions driven by experimental data10.1007/s10439-022-02917-0 ↗
27. Characterization of the protective capacity of flooring systems using force-deflection profiling10.1016/j.medengphy.2012.04.006 ↗
28. Fall severity and bone mineral density as risk factors for hip fracture in ambulatory elderly10.1001/jama.1994.03510260060029 ↗
29. The northeast hip fracture study group: Risk factors for falls as a cause of hip fracture in women10.1056/NEJM199105093241905 ↗
30. World-wide projections for hip fracture10.1007/PL00004148 ↗
31. Investigating the fall-injury reducing effect of impact absorbing flooring among female nursing home residents: initial results10.1136/injuryprev-2014-041468 ↗
32. Low-impact flooring: does it reduce fall-related injuries?10.1016/j.jamda.2017.01.012 ↗
33. Finite element analysis of energy-absorbing floors for reducing head injury risk during fall accidents10.3390/app132413260 ↗
34. Age-related changes in bone density, geometry and biomechanical properties of the proximal femur: CT-based 3D hip structure analysis in normal postmenopausal women10.1016/j.bone.2010.11.007 ↗
35. Iwamoto, M., Kisanuki, Y., Watanabe, I., Furusu, K., Miki, K., Hasegawa, J., 2002. Development of a finite element model of the total human model for safety (THUMS) and application to injury reconstruction. In: Proceedings of the International IRCOBI Conference. pp. 18–20.
36. Greater fall risk in elderly women than in men is associated with increased gait variability during multitasking10.1016/j.jamda.2016.02.009 ↗
37. Hip fractures in Finland between 1970 and 1997 and predictions for the future10.1016/S0140-6736(98)04235-4 ↗
38. Indoor and outdoor falls in older adults are different: the maintenance of balance, independent living, intellect, and Zest in the Elderly of Boston Study10.1111/j.1532-5415.2010.03062.x ↗
39. Kleiven, S., 2007. A parametric study of energy absorbing foams for head injury prevention. In: The 20th International Technical Conference on the Enhanced Safety of Vehicles Conference. ESV, Lyon, France, pp. 18–21.
40. Hip fracture risk functions for elderly men and women in sideways falls10.1016/j.jbiomech.2020.109771 ↗
41. Upright trunk and lateral or slight anterior rotation of the pelvis cause the highest proximal femur forces during sideways falls10.3389/fbioe.2022.1065548 ↗
42. Compliant flooring to prevent fall-related injuries in older adults: A scoping review of biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety10.1371/journal.pone.0171652 ↗
43. The effects of pad geometry and material properties on the biomechanical effectiveness of 26 commercially available hip protectors10.1016/j.jbiomech.2011.08.016 ↗
44. Low stiffness floors can attenuate fall-related femoral impact forces by up to 50% without substantially impairing balance in older women10.1016/j.aap.2009.03.001 ↗
45. Characterizing the effective stiffness of the pelvis during sideways falls on the hip10.1016/j.jbiomech.2010.03.025 ↗
46. Effect of compliant flooring on impact force during falls on the hip10.1002/jor.20172 ↗
47. The effects of body mass index and sex on impact force and effective pelvic stiffness during simulated lateral falls10.1016/j.clinbiomech.2013.10.002 ↗
48. Force magnitude and distribution during impacts to the hip are affected differentially by body size and body composition10.1016/j.jbiomech.2024.112213 ↗
49. Assessment of mechanical conditions in sub-dermal tissues during sitting: a combined experimental-MRI and finite element approach10.1016/j.jbiomech.2006.06.020 ↗
50. On challenges in clinical assessment of hip fracture risk using image-based biomechanical modelling: a critical review10.1007/s00774-020-01198-8 ↗
51. The coming acceleration of global population ageing10.1038/nature06516 ↗
52. The flooring for injury prevention (FLIP) study of compliant flooring for the prevention of fall-related injuries in long-term care: a randomized trial10.1371/journal.pmed.1002843 ↗
53. Finite element analysis of hip fracture risk in elderly female: The effects of soft tissue shape, fall direction, and interventions10.1016/j.jbiomech.2024.112199 ↗
54. Circumstances and consequences of falls in community-dwelling older women10.1089/jwh.2006.0245 ↗
55. Sideways fall-induced impact force and its effect on hip fracture risk: a review10.1007/s00198-017-4138-5 ↗
56. Oshita, F., Omori, K., Nakahira, Y., Miki, K., 2002. Development of a finite element model of the human body. In: 7th International LS-DYNA Users Conference, Vol. 14. pp. 205–212.
57. Roberts, C.W., Forman, J.L., Kerrigan, J.R., 2018. Injury risk functions for 5th percentile females: ankle inversion and eversion. In: Proceedings of the 2018 International IRCOBI Conference. pp. 702–717.
58. Hip protectors: recommendations for biomechanical testing—an international consensus statement (part I)10.1007/s00198-009-1045-4 ↗
59. Prediction of Femoral Impact Forces in Falls on the Hip10.1115/1.2895414 ↗
60. Energy-shunting hip padding system attenuates femoral impact force in a simulated fall10.1115/1.2794200 ↗
61. Force attenuation in trochanteric soft tissues during impact from a fall10.1002/jor.1100130621 ↗
62. Influence of nonlinear soft tissue modeling on the external and internal forces during lateral hip impacts10.1016/j.jmbbm.2021.104743 ↗
63. Schneider · 1983
64. Treatment of transient osteoporosis of the hip with intravenous zoledronate-a case report10.5535/arm.2011.35.3.432 ↗
65. Preventing fall-related vertebral fractures: effect of floor stiffness on peak impact forces during backward falls10.1097/BRS.0b013e31817bab05 ↗
66. Potential solutions for the mitigation of hip injuries caused by falls in older adults: a narrative review10.1093/gerona/glac211 ↗
67. A validated model of passive muscle in compression10.1016/j.jbiomech.2005.10.016 ↗
68. Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling10.1016/j.jbiomech.2008.02.007 ↗
69. Biomechanical responses and injuries in blunt lateral impact
70. Biomechanics of the human chest, abdomen, and pelvis in lateral impact10.1016/0001-4575(89)90070-5 ↗
71. A statistical distribution function of wide applicability10.1115/1.4010337 ↗
72. Factors related to occurrence of hip fracture during a fall on the hip10.1016/S0033-3506(02)00005-7 ↗
73. Novel safety floors do not influence early compensatory balance reactions in older adults10.1016/j.gaitpost.2014.03.015 ↗
74. The influence of novel compliant floors on balance control in elderly women—A biomechanical study10.1016/j.aap.2011.02.028 ↗
75. The influence of headform orientation and flooring systems on impact dynamics during simulated fall-related head impacts10.1016/j.medengphy.2011.11.012 ↗
76. The effect of fall biomechanics on risk for hip fracture in older adults: a cohort study of video-captured falls in long-term care10.1002/jbmr.4048 ↗
77. Validation of kinematics and lower extremity injuries estimated by total human model for safety in SUV to pedestrian impact test10.1299/jbse.5.340 ↗