journal article·2023-11

Aging of non-implanted Natrelle™ gel breast implants

Corinne Jung, Frédéric Bodin, Laetitia Ruffenach, Catherine Bruant Rodier, Florence Dieval

Publisher page

Abstract

This study questions the aging of non-implanted breast prostheses for a period of 9-60 months. Every 6 months, two non-implanted Natrelle™ prostheses were tested to measure the strength at break, the elongation at break, and the thickness of the shell. Then, the breaking stress was calculated from the preceding quantities. All these quantities were observed by separating the samples taken from the anterior and posterior sides of the prostheses. One-way ANOVA analyses (analysis of variance) were performed to define the influence of aging duration, lot membership, and side. In addition, the elongation at break and the thickness of the shell showed significant variations as a function of aging regardless of the side but without any trend emerging. For other quantities, there were significant disparities between the anterior and posterior sides of the prostheses, differences between prostheses from different lots, and similarities between prostheses from the same lot. Finally, the thickness is an important parameter. Since manufacturing is a manual process, it is necessary to check the thickness, which must be homogeneous on both sides. Always weaker on the anterior side than on the posterior side, it influences the mechanical properties. We recommend, like other studies, that its control be part of the quality controls during manufacturing.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Breast Implant and Reconstruction · Reconstructive Surgery and Microvascular Techniques · Reconstructive Facial Surgery Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. A retrospective analysis of ruptured breast implants10.5999/aps.2014.41.6.734 ↗
2. Aging of retrieved gel breast implants: a comparison between two product generations10.1016/j.jmbbm.2015.02.008 ↗
3. Protocol for retrieval and analysis of breast implants10.1615/JLongTermEffMedImplants.v13.i1.60 ↗
4. Evaluation of invitro degradation of commercially available breast implants10.1016/j.polymertesting.2019.106033 ↗
5. Hamilton · 2001
6. Incidence of silicone breast implant rupture10.1001/archsurg.138.7.801 ↗
7. Physical properties of silicone gel breast implants10.1093/asj/sjy149 ↗
8. Mechanical and surface chemical analysis of retrieved breast implants from a single centre10.1016/j.jmbbm.2018.10.042 ↗
9. Silicone gel breast implant failure: evaluation of properties of shells and gels for explanted prostheses and meta-analysis of literature rupture data10.1097/00000637-200209000-00001 ↗
10. Allergan NatrelleTM. Breast Implants and Tissue Expanders. Booklet provided in the Packaging of Each Prosthesis. Allergan Marlow International, Parkway, Marlow, Bucks, SL7 1YL, United Kingdom.
11. Failure of silicone gel breast implants: is the mechanical weakening due to shell swelling a significant cause of prostheses rupture?10.1016/j.jmbbm.2011.06.019 ↗
12. NF · 2018
13. 2018
14. Surveillance et changement des implants mammaires en gel de silicone: Étude rétrospective à propos de 130 cas de rupture d’implants10.1016/j.anplas.2015.07.006 ↗
15. An experimental analysis of shell failure in breast implants10.1016/j.jmbbm.2017.04.005 ↗
16. Biomechanical analysis of intact versus ruptured Poly Implant Prothèse breast implants10.1098/rsfs.2018.0086 ↗
17. On the failure of silicone breast implants: new insights by mapping the mechanical properties of implant shells10.1002/pi.4619 ↗