Influence of joint deformation on the auxetic behaviour of 3D printed polypropylene structures
Source abstract
Abstract
Auxetic structures studied in the literature are often based on relatively stiff, metallic materials and theories regarding their response to mechanical loading cannot be translated directly to polymeric materials. As “soft” auxetics increase in popularity for applications in tissue engineering further investigation into the joint behaviour and effect on their Poisson's ratio is required. 3D printed polypropylene auxetic mesh structures were produced to compare to the requirements for biological cell-stretching devices while investigating the deformation mechanics. The behaviour of the meshes was characterised with tensile force-strain curves and high-definition imaging and the effect of joint behaviour on the Poisson's ratio was evaluated. Isolated unit cell samples of the re-entrant mesh were produced to characterise the in- and out-of-plane behaviour for geometries comprising re-entrant strut angles of 30, 45, and 60° to the tensile straining direction. Force-strain curves with three distinct phases were observed, with linear, plateau, and terminal regions characteristic of re-entrant honeycomb structures. A constant negative Poisson's ratio was measured up to a critical transition strain, at which point it is theorised that the onset of buckling triggers bending-dominated deformation to occur, out-of-plane. The production of full-scale mesh samples with the same 30, 45, and 60° geometry resulted in consistent values for critical transition strain and Poisson's ratios. An auxetic region of strain was defined, where the force is linear and a homogeneous negative Poisson's ratio can be maintained. This region represents the limit within which a biological cell-stretching device could operate successfully for the current mesh design. • 3 stages of deformation: elastic, plastic bending, and stretching, shown by re-entrant unit cells made from 3D printed PP. • The critical transition from elastic to plastic bending prompted out-of-plane movement via strut buckling. • Constant negative Poisson's ratios were exhibited prior to the critical transition. • Auxetic structures produced well-defined homogenous strain profiles desirable for biological cell-stretching devices.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Cellular and Composite Structures · Additive Manufacturing and 3D Printing Technologies · Polymer composites and self-healing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Fabrication and characterization of Re-entrant honeycomb polyurethane aerogels10.1021/acsapm.2c00269 ↗
2. Size and print path effects on mechanical properties of material extrusion 3D printed plastics10.1007/s40964-022-00275-w ↗
3. An Auxetic structure configured as oesophageal stent with potential to be used for palliative treatment of oesophageal cancer; development and in vitro mechanical analysis10.1007/s10856-011-4436-y ↗
4. Out-of-plane and in-plane compression of additively manufactured auxetic structures10.1016/j.ast.2020.106107 ↗
5. Auxetic mechanical metamaterials and their futuristic developments: a state-of-art review
6. Rationally designed anisotropic and auxetic hydrogel patches for adaptation to dynamic organs10.1002/adfm.202207590 ↗
7. Lattice metamaterials with mechanically tunable Poisson's ratio for vibration control10.1103/PhysRevApplied.7.024012 ↗
8. In-plane elasticity of the re-entrant auxetic hexagonal honeycomb with hollow-circle joint10.1016/j.ast.2022.107432 ↗
9. 3D-biofabricated chondrocyte-laden decellularized extracellular matrix-contained gelatin methacrylate auxetic scaffolds under cyclic tensile stimulation for cartilage regeneration10.1088/1758-5090/ace5e1 ↗
10. Cyclic tensile stimulation enrichment of Schwann cell-laden auxetic hydrogel scaffolds towards peripheral nerve tissue engineering10.1016/j.matdes.2020.108982 ↗
11. Frequency and peak stretch magnitude affect alveolar epithelial permeability10.1183/09031936.00141007 ↗
12. Edge effects of a hexagonal honeycomb on the Poisson's ratio and young's modulus10.1002/pssb.201900511 ↗
13. Laser‐made 3D auxetic metamaterial scaffolds for tissue engineering applications10.1002/mame.202070016 ↗
14. 3D printed vs. Commercial polypropylene surgical meshes: a comparative analysis of tensile strength
15. Experimental study of auxetic behavior of re-entrant honeycomb with curvilinear elements10.22226/2410-3535-2017-2-81-84 ↗
16. An improved analytical model for the elastic constants of auxetic and conventional hexagonal honeycombs10.1177/026248931103000602 ↗
17. Honeycomb composites with auxetic out-of-plane characteristics10.1016/j.compstruct.2013.06.009 ↗
18. In situ real time defect detection of 3D printed parts
19. Fabrication of multi-scale and tunable auxetic scaffolds for tissue engineering10.1016/j.matdes.2020.109277 ↗
20. Auxetic cardiac patches with tunable mechanical and conductive properties toward treating myocardial infarction10.1002/adfm.201800618 ↗
21. Effects of raster layup and printing speed on strength of 3D-printed structural components10.1016/j.prostr.2020.10.083 ↗
22. Auxetic structures for tissue engineering scaffolds and biomedical devices10.3390/ma14226821 ↗
23. Auxetic mechanical metamaterials: from soft to stiff10.1088/2631-7990/ace668 ↗
24. Analogies across auxetic models based on deformation mechanism
25. Antisense oligonucleotides for PDGF-B and its receptor inhibit mechanical strain-induced fetal lung cell growth10.1152/ajplung.1995.269.2.L178 ↗
26. Invited Review: mechanochemical signal transduction in the fetal lung10.1152/jappl.2000.89.5.2078 ↗
27. Auxetic metamaterials for biomedical devices: current situation, main challenges, and research trends10.3390/ma15041439 ↗
28. A nonlinear mechanics model of bio-inspired hierarchical lattice materials consisting of horseshoe microstructures10.1016/j.jmps.2016.02.012 ↗
29. Models for the elastic deformation of honeycombs10.1016/S0263-8223(96)00054-2 ↗
30. Characterization of the FlexcellTM UniflexTM cyclic strain culture system with U937 macrophage-like cells10.1016/j.biomaterials.2005.05.070 ↗
31. Computational design and simulation of bending-active auxetic structures10.11606/gtp.v11i2.118141 ↗
32. Breathing in vitro: designs and applications of engineered lung models10.1177/20417314211008696 ↗
33. Precise determination of the Poisson ratio in soft materials with 2D digital image correlation10.1039/c3sm50901j ↗
34. Mechanical stretching for tissue engineering: two-dimensional and three-dimensional constructs10.1089/ten.teb.2011.0465 ↗
35. The 3D printing of freestanding PLLA thin layers and improving first layer consistency through the introduction of sacrificial PVA10.3390/app11146320 ↗
36. Auxetics in biomedical applications: a review
37. Numerical and experimental uniaxial loading on in-plane auxetic honeycombs10.1243/0309324001514152 ↗
38. Optimisation of the adhesion of polypropylene-based materials during extrusion-based additive manufacturing10.3390/polym10050490 ↗
39. Equibiaxial deformation-induced injury of alveolar epithelial cells in vitro10.1152/ajplung.1998.275.6.L1173 ↗
40. Review: auxetic polymer-based mechanical metamaterials for biomedical applications10.1021/acsbiomaterials.2c00109 ↗
41. Wei · 2023
42. The effect of unit cell size and topology on tensile failure behavior of 2D lattice structures10.1016/j.ijmecsci.2019.105342 ↗
43. Radial compressive property and the proof-of-concept study for realizing self-expansion of 3D printing polylactic acid vascular stents with negative Poisson's ratio structure10.3390/ma11081357 ↗
44. Pluripotent stem cell expansion and neural differentiation in 3-D scaffolds of tunable Poisson's ratio10.1016/j.actbio.2016.11.025 ↗
45. Mechanical properties of 3D re-entrant honeycomb auxetic structures realized via additive manufacturing10.1016/j.ijsolstr.2015.05.005 ↗
46. Dynamic tensile behaviour of re-entrant honeycombs10.1016/j.ijimpeng.2019.103497 ↗
47. Energy absorption of re-entrant honeycombs in tension and compression10.1016/j.engstruct.2023.116237 ↗
48. Tensile behavior of an auxetic structure: analytical modeling and finite element analysis10.1016/j.ijmecsci.2017.12.029 ↗
49. Large deformation of an auxetic structure in tension: experiments and finite element analysis10.1016/j.compstruct.2017.09.076 ↗
50. In vitro cell stretching devices and their applications: from cardiomyogenic differentiation to tissue engineering