Experimental and micro-finite element analysis of the toggling behaviour of a carbon fibre-reinforced PEEK pedicle screw

Matteo Frigelli, Dominic Mischler, Michael Indermaur, Patrik Wili, Amin Dolati, Florian Kessler, Lara Tenisch, Laura Hüsken, Maarten Spruit, Peter Varga, Philippe Zysset

Abstract

Primary stability of pedicle screws is critical for successful spinal fixation, particularly in osteoporotic patients, where screw loosening occurs in over 50 % of cases. This study combined experimental and numerical approaches to evaluate the primary stability of carbon fibre-reinforced polyether-ether-ketone (CF/PEEK) screws under toggling loading conditions. Fifteen human cadaveric vertebrae with low bone mineral density were tested using a multidirectional loading setup with custom-designed, 3D-printed guides for accurate screw placement. Toggling tests were conducted under displacement-controlled linear loading–unloading ramps with increasing displacements (1, 2, and 4 mm). To complement the experiments, a sample-specific, explicit non-linear micro-finite element (μFE) model was developed to simulate the toggling tests. Experimental and numerical peak forces and tangential stiffnesses were compared at different displacement levels. Experimentally, no significant correlation was found between mean bone volume fraction in the vicinity of the screw and peak forces. Similarly, volumetric bone mineral density did not show significant correlation with the experimental biomechanical variables. However, μFE-derived peak forces showed significant correlation with experimental measurements at all displacement levels (R 2 = 0.67, R 2 = 0.60, R 2 = 0.59 at 1 mm, 2 mm and 4 mm displacement, respectively), with the model slightly overestimating the experimental values at higher displacements (e.g., 4 mm). Across all data points, μFE and experimental peak forces strongly correlated (R 2 = 0.92), following a power-law relationship. This study demonstrates that non-linear μFE models can reliably predict the primary stability of pedicle screws, offering potential for optimizing screw designs and reducing clinical failure rates associated with loosening. • Micro-finite element analysis well replicates toggling experiments' peak forces. • Bone volume fraction does not predict toggling peak forces measured experimentally. • Explicit non-linear simulations capture bone behaviour at high strains. • 3D-printed specimen-specific guides can improve experimental preoperative planning.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Elasticity and Material Modeling · Advanced machining processes and optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications10.1016/j.jmbbm.2016.06.005 ↗
2. A nonlocal constitutive model for trabecular bone softening in compression10.1007/s10237-010-0200-3 ↗
3. Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions10.1016/j.jbiomech.2017.12.023 ↗
4. Biomechanical analysis of pedicle screws in osteoporotic bone with bioactive cement augmentation using simulated in vivo multicomponent loading10.1097/BRS.0b013e3181d449ec ↗
5. Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel10.1007/s005860050218 ↗
6. Wear of PEEK-OPTIMA® and PEEK-OPTIMA®-Wear performance articulating against highly cross-linked polyethylene10.1177/0954411915576353 ↗
7. Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly10.1007/s00068-013-0310-6 ↗
8. Computational model predicts risk of spinal screw loosening in patients10.1007/s00586-022-07187-x ↗
9. Pedicle screw loosening: a clinically relevant complication?10.1007/s00586-015-3768-6 ↗
10. Quantitation in positron emission computed tomography: 1. Effect of object size
11. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
12. Bone mineral density surrounding the screw thread predicts the risk of pedicle screw loosening10.1016/j.jbiomech.2025.112542 ↗
13. A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: cadaveric evaluation after cervical pedicle screw placement10.1097/01.rct.0000250117.18080.d8 ↗
14. In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application10.1016/j.jmbbm.2017.10.030 ↗
15. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading10.1007/s00586-018-5538-8 ↗
16. Biomechanical effects of posterior pedicle screw-based instrumentation using titanium versus carbon fiber reinforced PEEK in an osteoporotic spine human cadaver model10.1016/j.clinbiomech.2020.105153 ↗
17. A threshold selection method from gray-level histograms10.1109/TSMC.1979.4310076 ↗
18. Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis10.1016/j.jmbbm.2019.06.024 ↗
19. Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone10.1016/j.jmbbm.2021.105002 ↗
20. Experimental and numerical investigation of secondary screw perforation in the human proximal humerus10.1016/j.jmbbm.2021.104344 ↗
21. Mechanical behavior of the human lumbar and Lumbosacral spine as shown by three-dimensional load-displacement curves10.2106/00004623-199403000-00012 ↗
22. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation10.1016/j.spinee.2008.08.002 ↗
23. Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial pilon: a quantitative assessment in 3D
24. Compressive fatigue behavior of human vertebral trabecular bone10.1016/j.jbiomech.2005.04.033 ↗
25. Loads on an internal spinal fixation device during physical therapy10.1093/ptj/82.1.44 ↗
26. Mid-range outcomes in 64 consecutive cases of multilevel fusion for degenerative diseases of the lumbar spine
27. The effect of movement on the holding power of screws in bone10.1097/00003086-197509000-00032 ↗
28. Timing of PMMA cement application for pedicle screw augmentation affects screw Anchorage10.1007/s00586-017-5053-3 ↗
29. Computational analysis of primary implant stability in trabecular bone10.1016/j.jbiomech.2014.12.008 ↗
30. Screw insertion in trabecular bone causes peri-implant bone damage10.1016/j.medengphy.2016.01.006 ↗
31. A novel in silico method to quantify primary stability of screws in trabecular bone10.1002/jor.23551 ↗
32. Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae10.1007/s10237-011-0347-6 ↗
33. The dynamic friction coefficient of the wet bone-implant interface: influence of load, speed, material and surface finish10.1016/j.biotri.2019.03.002 ↗
34. Titanium versus stainless steel for anterior spinal fusions: an analysis of rod stress as a predictor of rod breakage during physiologic loading in a bovine model10.1097/01.brs.0000251036.99413.20 ↗
35. An explicit micro‐FE approach to investigate the post‐yield behaviour of trabecular bone under large deformations10.1002/cnm.3188 ↗
36. Individualized prediction of pedicle screw fixation strength with a finite element model10.1080/10255842.2019.1709173 ↗
37. The discrete nature of trabecular bone microarchitecture affects implant stability10.1016/j.jbiomech.2011.12.024 ↗