journal article·2026-01Open access

Advancing glaucoma research with multiphysics continuum mechanics modelling: Opportunities and open challenges

Daniel Sebastia-Saez, Jinyuan Luo, Mengqi Qin, Tao Chen, Cynthia Yu-Wai-Man

Abstract

This review examines the emerging role of mechanistic mathematical models based on continuum mechanics to address current challenges in glaucoma research. At present, the advent of Artificial Intelligence and data-based models have resulted in significant progress in drug candidate screening, target identification and delivery optimization for glaucoma treatment. Physics-based models on the other hand offer mechanistic insight by modelling fundamental physical knowledge. Mechanistic models, and specifically those based on continuum mechanics, have the potential to contribute to a better understanding of glaucoma through the description of intraocular fluid dynamics, mass and heat transfer, and other basic physical phenomena. So far, these models have expanded our understanding of ocular fluid dynamics, including descriptions of fluid flow profiles, within the anterior chamber of the eye under glaucomatous conditions. With the ongoing development of multiphysics modelling frameworks, there is increasing potential to apply these tools to a wide range of current challenges within the field of glaucoma. These challenges include glaucoma drainage devices, minimally invasive surgical procedures, therapeutic contact lenses, laser-based interventions like peripheral iridotomy, and the design and optimization of biodegradable drug-releasing intracameral implants, which support patient-specific strategies for glaucoma diagnosis and treatment.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Glaucoma and retinal disorders · Corneal surgery and disorders · Proteoglycans and glycosaminoglycans research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (98)

Show source-provided references
1. Computational modeling of intraocular drug delivery supplied by porous implants10.1007/s13346-020-00878-2 ↗
2. Fluid–structure simulation of a general non-contact tonometry. A required complexity?10.1016/j.cma.2018.05.031 ↗
3. Modelling aqueous humor outflow through trabecular meshwork
4. An aqueous humour fluid dynamic study for normal and glaucomatous eye conditions
5. A computational fluid dynamics investigation of endothelial cell damage from glaucoma drainage devices10.1038/s41598-023-50491-9 ↗
6. Optimization of patient positioning for improved healing after corneal transplantation10.1016/j.jbiomech.2023.111510 ↗
7. Characterization of parafoveal hemodynamics associated with diabetic retinopathy with adaptive optics scanning laser ophthalmoscopy and computational fluid dynamics
8. Effect of aging on heat transfer, fluid flow and drug transport in anterior human eye: a computational study10.1016/j.jconrel.2020.08.044 ↗
9. Numerical study of aqueous humor flow and iris deformation with pupillary block and the efficacy of laser peripheral iridotomy10.1016/j.clinbiomech.2022.105579 ↗
10. Trabeculectomy. Preliminary report of a new method10.1016/0002-9394(68)91288-9 ↗
11. Numerical simulation of aqueous flow in laser iridotomy10.11159/htff19.174 ↗
12. Modeling the effects of disease, drug properties, and material on drug transport from intraocular lenses10.1167/tvst.11.5.14 ↗
13. Simulation of time-fractional oxygen diffusion in cornea coated by contact-lens10.1007/s11043-022-09545-0 ↗
14. In vitro and computational modelling of drug delivery across the outer blood–retinal barrier10.1098/rsfs.2019.0132 ↗
15. Numerical simulation of viscoelastic fluid–structure interaction benchmarks and their application to the human eye10.1007/s42452-022-05185-8 ↗
16. Mathematical modeling of ocular epithelial transport: a review
17. Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens10.1371/journal.pone.0202128 ↗
18. Numerical simulation of aqueous humor flow: from healthy to pathologic situations
19. A combined approach for the analysis of ocular fluid dynamics in the presence of saccadic movements10.1007/s10439-018-02110-2 ↗
20. Evaluation of the ocular fluid dynamic effects on intraocular magnesium-based device: a comparison between CFD and FSI approaches10.1016/j.medengphy.2020.10.004 ↗
21. Fluid mechanics of the human eye: aqueous humour flow in the anterior chamber10.1007/s11538-005-9015-2 ↗
22. Contact lenses as ophthalmic drug delivery systems: a review10.3390/polym13071102 ↗
23. The aqueous humour dynamics in primary angle closure disease: a computational study10.1136/bjo-2023-325109 ↗
24. Changes in aqueous humor dynamics with age and glaucoma10.1016/j.preteyeres.2004.10.003 ↗
25. Computational modeling of fluid flow and intra-ocular pressure following glaucoma surgery10.1371/journal.pone.0013178 ↗
26. Comprehensive study of traditional glaucoma drainage devices and emerging Micro Invasive Glaucoma Surgery (MIGS) devices: a review10.1016/j.bea.2024.100140 ↗
27. Computational fluid dynamics (CFD) simulation analysis on retinal gas cover rates using computational eye models10.1038/s41598-021-84574-2 ↗
28. Numerical simulation of the flow of aqueous humor in the Schlemm's canal10.1016/j.medengphy.2020.12.005 ↗
29. Drug delivery with therapeutic lens for the glaucoma treatment in the anterior eye chamber: a numerical simulation10.1016/j.bea.2022.100032 ↗
30. Modeling passive mechanical interaction between aqueous humor and iris10.1115/1.1411972 ↗
31. Artificial intelligence in glaucoma: opportunities, challenges, and future directions10.1186/s12938-023-01187-8 ↗
32. Characterization of micro-invasive trabecular bypass stents by ex vivo perfusion and computational flow modeling
33. 3D-printed long-acting 5-fluorouracil implant to prevent conjunctival fibrosis in glaucoma10.1093/jpp/rgac100 ↗
34. Simulation of aqueous humour flow driven by buoyancy effects and flow through pupil aperture during descemet membrane detachment10.37934/cfdl.12.4.1223 ↗
35. Computational modeling of drug distribution in the posterior segment of the eye: effects of device variables and positions10.1016/j.mbs.2014.06.008 ↗
36. CFD analysis of the ahmed glaucoma valve and design of an alternative device10.1080/10255841003717616 ↗
37. Computational and experimental analysis of an in vitro microfluidic experimental setup on testing molteno, ahmed valve and Ex-Press implants and their critical comparisons10.1080/02713683.2021.1951298 ↗
38. Morphological and biomechanical analyses of the human healthy and glaucomatous aqueous outflow pathway: imaging-To-Modeling10.1016/j.cmpb.2023.107485 ↗
39. Modeling the biomechanics of the conventional aqueous outflow pathway microstructure in the human eye10.1016/j.cmpb.2022.106922 ↗
40. High-resolution modeling of aqueous humor dynamics in the conventional outflow pathway of a normal human donor eye10.1016/j.cmpb.2024.108538 ↗
41. Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics
42. Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics10.1007/s00417-016-3304-3 ↗
43. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation10.1007/s00417-011-1850-2 ↗
44. Analytical and computational modeling of sustained-release drug implants in the vitreous humor10.1115/1.4051785 ↗
45. Computational methods in glaucoma research: current status and future outlook10.1016/j.mam.2023.101222 ↗
46. Smart contact lens systems for ocular drug delivery and therapy10.1016/j.addr.2023.114817 ↗
47. Numerical model to predict and compare the hypotensive efficacy and safety of minimally invasive glaucoma surgery devices10.1371/journal.pone.0239324 ↗
48. Extended pharmacokinetic model of the intravitreal injections of macromolecules in rabbits. Part 2: parameter estimation base on concentration dynamics in the vitreous, retina, and aqueous humor10.1007/s11095-020-02946-1 ↗
49. Extended pharmacokinetic model of the rabbit eye for intravitreal and intracameral injections of macromolecules: quantitative analysis of anterior and posterior elimination pathways10.1007/s11095-018-2435-0 ↗
50. Translating minimally invasive glaucoma surgery devices10.1111/cts.12660 ↗
51. The surgical management of glaucoma: a review10.1111/ceo.14028 ↗
52. Computational fluid dynamics assisted characterization of parafoveal hemodynamics in normal and diabetic eyes using adaptive optics scanning laser ophthalmoscopy10.1364/BOE.7.004958 ↗
53. Simulation of air puff tonometry test using arbitrary lagrangian–eulerian (ALE) deforming mesh for corneal material characterisation
54. Numerical simulation of the aqueous humor flow in the eye drainage system; a healthy and pathological condition comparison10.1016/j.medengphy.2020.07.010 ↗
55. A novel patient-oriented numerical procedure for glaucoma drainage devices10.1002/cnm.3141 ↗
56. Simulating dissolution of intravitreal triamcinolone acetonide suspensions in an anatomically accurate rabbit eye model10.1007/s11095-010-0163-1 ↗
57. Physiologically based ocular pharmacokinetic modeling using computational methods10.1016/j.drudis.2019.05.039 ↗
58. Factors affecting glaucoma medication adherence and interventions to improve adherence: a narrative review10.1007/s40123-023-00797-8 ↗
59. A mechanistic model of aqueous humor flow to study effects of angle closure on intraocular pressure10.1167/tvst.12.1.16 ↗
60. Biomechanical assessment in models of glaucomatous optic neuropathy10.1016/j.exer.2015.05.024 ↗
61. Computational modeling of intraocular gas dynamics10.1088/1478-3975/12/6/066019 ↗
62. Evaluation of the effect of hemodynamic factors on retinal microcirculation by using 3D confocal image-based computational fluid dynamics10.3389/fbioe.2024.1489172 ↗
63. Minimally invasive glaucoma surgery (MIGS) devices: risks, benefits and suitability
64. Manufacturing and characterisation of 3D-printed sustained-release timolol implants for glaucoma treatment10.1007/s13346-024-01589-8 ↗
65. Modeling and characterization of a valved glaucoma drainage device with implications for enhanced therapeutic efficacy10.1109/TBME.2005.845222 ↗
66. Drug delivery from a ring implant attached to intraocular lens: an in-silico investigation10.1016/j.xphs.2024.09.001 ↗
67. Computational and experimental analysis of a glaucoma flat drainage device10.1016/j.jbiomech.2021.110234 ↗
68. Developing a synergistic rate-retarding polymeric implant for controlling monoclonal antibody delivery in minimally invasive glaucoma surgery10.1016/j.ijbiomac.2024.132655 ↗
69. Glaucoma: novel antifibrotic therapeutics for the trabecular meshwork10.1016/j.ejphar.2023.175882 ↗
70. A new self-adjustable glaucoma valve10.3389/fbioe.2024.1383459 ↗
71. Trabeculectomy: does it have a future?10.7759/cureus.27834 ↗
72. Trabeculectomy bleb-associated infections10.1016/j.survophthal.2017.01.009 ↗
73. Minimally invasive glaucoma surgery procedure in the human eye. A fluid structure interaction study10.1002/cnm.70062 ↗
74. Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry10.1007/s10237-009-0159-0 ↗
75. Evaluating the effectiveness of laser peripheral iridotomy on angle-closure diseases: the role of spectral domain anterior segment optical coherence tomography (SD AS-OCT) in Indonesia tertiary eye hospital10.2174/0118743641337429241016053642 ↗
76. Silicone oil tamponade–retina contact in highly myopic eyes with and without encircling bands: a computational fluid dynamics study10.1167/tvst.11.6.1 ↗
77. Computational fluid dynamics of intraocular silicone oil tamponade10.1167/tvst.10.8.22 ↗
78. Mathematical models of ocular drug delivery10.1167/iovs.65.11.28 ↗
79. Characterization of an active microvalve for glaucoma using fluid-structure interaction
80. Mathematical modelling of the dynamic response of an implantable enhanced capacitive glaucoma pressure sensor
81. Phacoemulsification versus laser peripheral iridotomy for treating primary angle closure glaucoma: a systematic review and meta-analysis10.2147/OPTH.S446285 ↗
82. Simulation of heat exposure and damage to the eye lens in a neighborhood bakery10.1016/j.exer.2008.04.007 ↗
83. Flow dynamics of vitreous humour during saccadic eye movements10.1016/j.jmbbm.2020.103860 ↗
84. Geometric model and numerical study of aqueous humor hydrodynamics in the human eye10.1155/2022/4756728 ↗
85. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis10.1016/j.ophtha.2014.05.013 ↗
86. Biodegradable polymer-based drug-delivery systems for ocular diseases10.3390/ijms241612976 ↗
87. 3D simulation of the aqueous flow in the human eye10.1016/j.medengphy.2012.02.007 ↗
88. Modeling the mechanical parameters of glaucoma10.1089/ten.teb.2019.0044 ↗
89. Estimating human trabecular meshwork stiffness by numerical modeling and advanced OCT imaging10.1167/iovs.17-22175 ↗
90. How can machine learning and multiscale modeling benefit ocular drug development?10.1016/j.addr.2023.114772 ↗
91. Stability of the interface between two immiscible liquids in a model eye subject to saccadic motion10.1115/1.4053004 ↗
92. Fluid and structure coupling analysis of the interaction between aqueous humor and Iris10.1186/s12938-016-0261-3 ↗
93. The pathophysiology and treatment of glaucoma: a review10.1001/jama.2014.3192 ↗
94. Correlation study of biomechanical changes between diabetic eye disease and glaucoma using finite element model of human eye with different iris-lens channel distances10.1016/j.medengphy.2022.103910 ↗
95. Contact lens as an emerging platform for ophthalmic drug delivery: a systematic review
96. Analysis of topical dosing and administration effects on ocular drug delivery in a human eyeball model using computational fluid dynamics10.1016/j.compbiomed.2021.105016 ↗
97. Personalized medicine in ocular fibrosis: myth or future biomarkers10.1089/wound.2015.0677 ↗
98. Computer modeling of drug delivery in the anterior human eye after subconjunctival and episcleral implantation10.1016/j.compbiomed.2017.07.016 ↗